4.7 Configuration [1]
Feature Guide
321
Value Range
8 × n (n=3–191) ms
Programming References
Feature Guide References
None
DTMF-R STD Detection Time
Specifies the minimum time required by the PBX to detect the DTMF tone.
Default
30 ms
Value Range
2 × n (n=1–31) ms
Programming References
Feature Guide References
None
4.7.4
Slot [1-1] LCO Card Property
The properties of the analog CO line cards can be specified.
Outgoing Guard Time
Specifies the length of time after a CO line is disconnected, during which the PBX cannot seize the line.
Default
3 s
Value Range
3–6 s
Programming References
Feature Guide References
None