2.11 Power Failure Connections
Installation Manual
151
2.11 Power Failure Connections
2.11.1 Power Failure Connections
Connection
Power Failure Connection connects a specific SLT and a CO line in the event of power failure. The following
CO line and extension cards can be used for Power Failure Connections:
•
Analog CO line cards:
LCOT16 (4 PFT ports), and LCOT8 (2 PFT port), port)
•
Extension cards:
MSLC16 (4 PFT ports), SLC16 (4 PFT ports), DHLC8 (2 PFT port) and SLC8
(2 PFT port)
To 1 analog CO line card, connect only 1 extension card.
Note
By programming the Hybrid IP-PBX, a CO line conversation established during power failure can be
maintained even when the power returns and the connection is switched back to the normal
configuration from the Power Failure Connection. However, if no special programming is performed, the
connection will be dropped when power returns.
Accessory and User-supplied Items
Accessory (included):
none
User-supplied (not included):
RJ11 connectors
R2
R1
T1
T2
T2
T1
R1
R2
RJ11
CO Line Card
(e.g., LCOT8)
Extension Card
(e.g., SLC8)
To CO line
To SLT
Содержание KX-TDA100 KX-TDA200
Страница 16: ...16 Installation Manual 5 1 Revision History 186 5 1 1 Version 1 1 186 5 1 2 Version 2 0 187 Index 189 ...
Страница 34: ...1 4 Specifications 34 Installation Manual ...
Страница 156: ...2 12 Starting the Hybrid IP PBX 156 Installation Manual ...
Страница 184: ...4 1 Troubleshooting 184 Installation Manual ...
Страница 185: ...Installation Manual 185 Section 5 Appendix ...
Страница 188: ...5 1 Revision History 188 Installation Manual ...
Страница 189: ...Installation Manual 189 Index ...
Страница 193: ...Index Installation Manual 193 ...