2.5.4.6 Trunk Busy Out
Description
The PBX can monitor the loop current sent through analogue trunks, preventing users from seizing trunks
where a loop current is not detected. When loop currents are not detected, trunks are set to Busy Out status,
and become unable to make or receive calls. A trunk in Busy Out status cannot be used for making calls as a
TIE line, as part of a trunk group, or with the ARS feature, and cannot receive trunk calls. If a user tries to seize
a trunk set to Busy Out status, the user will hear a reorder tone.
This is useful if some or all trunks are occasionally unavailable because of problems with the external
telecommunications environment.
Conditions
•
Loop current detection is performed on active trunks whenever the trunk is seized and/or at fixed intervals.
•
When a trunk is in busy-out status, loop current detection is performed at fixed intervals, returning the trunk
to in-service status once a loop current is detected. An extension assigned as the manager can manually
change the trunk back to in-service status.
•
Trunk status changes are recorded in the error log of the PBX.
•
Busy Out status is maintained even when the PBX is reset.
•
Busy Out status is cleared when:
–
a call is successfully received (i.e., a loop current is detected) on that trunk.
–
the S-CO button for that trunk is pressed and a loop current is detected.
PC Programming Manual References
9.24 PBX Configuration—[1-1] Configuration—Slot—Port Property - LCO Port—
10.6.1 PBX Configuration—[2-6-1] System—Numbering Plan—Main—Features—
10.7.1 PBX Configuration—[2-7-1] System—Class of Service—COS Settings—Manager—
10.9 PBX Configuration—[2-9] System—System Options—Option 5—
Busy Out—Busy Out for Analogue
PT Programming Manual References
Feature Manual References
Operating Manual References
2.1.6 Allowing Users to Seize an Unavailable Outside Line (Trunk Busy Out)
112
Feature Manual
2.5.4 Trunk Call Features
Содержание KX-NS700
Страница 16: ...16 Feature Manual Table of Contents...
Страница 17: ...Section 1 For Your Safety Feature Manual 17...
Страница 20: ...20 Feature Manual 1 1 1 For Your Safety...
Страница 21: ...Section 2 Call Handling Features Feature Manual 21...
Страница 42: ...PT Programming Manual References 720 Doorphone Call Destination 42 Feature Manual 2 1 2 Internal Call Features...
Страница 59: ...632 Maximum Number of Agents Feature Manual 59 2 2 2 Incoming Call Distribution Group Features...
Страница 109: ...Operating Manual References 1 2 1 Basic Calling Feature Manual 109 2 5 4 Trunk Call Features...
Страница 176: ...Feature Manual References 2 21 2 Flexible Buttons 176 Feature Manual 2 11 6 Flash Recall Terminate...
Страница 195: ...Operating Manual References 1 4 2 Holding a Call Feature Manual 195 2 13 1 Call Hold...
Страница 230: ...Operating Manual References 1 7 1 Paging 1 7 2 Answering Denying a Paging Announcement 230 Feature Manual 2 17 1 Paging...
Страница 326: ...326 Feature Manual 2 30 2 Outgoing Message OGM...
Страница 327: ...Section 3 Unified Messaging System Feature Manual 327...
Страница 377: ...Section 4 Network Features Feature Manual 377...
Страница 466: ...466 Feature Manual 4 3 6 Network ICD Group...
Страница 467: ...Section 5 System Configuration and Administration Features Feature Manual 467...
Страница 507: ...Feature Manual References 6 1 Capacity of System Resources Feature Manual 507 5 2 4 Portable Station PS Features...
Страница 560: ...560 Feature Manual 5 5 7 PING Confirmation...
Страница 561: ...Section 6 Appendix Feature Manual 561...
Страница 578: ...578 Feature Manual 6 5 6 PFMPR Software File Version 004 6xxxx...
Страница 579: ...Feature Manual 579 Notes...