Maximum Number of Calls
Cell Station
Maximum Calls
Compatible Portable Station
KX-NCP0158
8
•
KX-TD7685
•
KX-TD7695
•
KX-TD7696
Note
For more details about the Portable Station (PS), refer to the Operating Instructions of the PS.
Maximum Number of CSs Supported by PBX
Notice
The CSs are for connection to specified Panasonic PBXs only.
The following number of CSs can be supported by each PBX.
PBX
Connected via
Maximum Number
KX-NCP0158
KX-NCP500/KX-NCP1000
LAN
8
KX-TDE100/KX-TDE200/KX-TDE600
16
Required Distances between Equipment
CAUTION
Maintain the distances listed below between equipment in order to prevent noise, interference or the
disconnection of a conversation. (The distance may vary depending on the environment.)
Equipment
Distance
CS and office equipment such as a computer, telex, fax
machine, etc.
More than 2 m (6 ft 7 in)
CS and PS
More than 1 m (3 ft 3 in)
Each CS
More than 3 m (10 ft)
Each PS
More than 0.5 m (1 ft 8 in)
PBX and CS
More than 2 m (6 ft 7 in)
Notice
If multiple CSs cover the same area, the phone connection may become noisy or the number of possible
simultaneous calls with PSs may decrease due to interference between the CSs. For details, refer
to "5 Site Survey Using the KX-TD7685/KX-TD7695/KX-TD7696—Testing the Radio Signal Strength".
The required distance between CSs may vary depending on the environment of the installation site and
conditions in which the wireless system is used. Conduct a site survey to determine the appropriate
distance.