Default Value
0
REORDER_TONE_RPT
Value Format
INTEGER
Description
Specifies whether the reorder tone is repeated.
Value Range
0–1
–
0: No Repeat
–
1: Repeat
Default Value
1
REORDER_TONE_TIMING
Value Format
Comma-separated Integer
Description
Specifies the pattern, in milliseconds, of reorder tones using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range
0–16000 (msec) (0: Continuous)
Note
•
Avoid setting 1–50 for any of the values.
Default Value
60,250,190
Web User Interface Reference
RINGBACK_TONE_FRQ
Value Format
Comma-separated Integer
Description
Specifies the dual-tone frequencies, in hertz, of ringback tones using
2 whole numbers separated by a comma.
Value Range
0, 200–2000 (Hz) (0: No tone)
Default Value
440,480
Web User Interface Reference
RINGBACK_TONE_GAIN
Value Format
INTEGER
Description
Specifies the gain, in decibels, of the ringback tone.
Value Range
-24–24 (dB)
Default Value
0
RINGBACK_TONE_RPT
Value Format
INTEGER
5.3.33 Tone Settings
324
Administrator Guide
Document Version: 2017-07