6.
Explanation of Communication and Compression Technology
a.
G3 Communication Signals (T. 30 Binary Process)
For G3 Facsimile communication, this is the procedure for exchanging control signals between the sending and receiving
machines both before and after transmission of image signals.
Control signals at 300 bps FSK are: 1850 Hz...0, 1650Hz...1.
An example of a binary process in G3 communication is shown below.
Explanation of Signals
Control signals are comprised mainly of 8-bit identification signals and the data signals added to them. Data signals are added
to DIS and DCS signals.
Signal.....DIS (Digital Identification Signal)
Identification Signal Format.....00000001
Function:
Notifies the capacity of the receiving unit. The added data signals are as follows.
Signal.....DCS (Digital Command Signal)
Identification Signal Format.....X1000001
Example
(Some models do not support the following items.):
Bit No.
DIS/DTC
DCS
1
Transmitter --- T.2 operation
2
Receiver --- T.2 operation
Receiver --- T.2 operation
3
T.2 IOC = 176
T.2 IOC = 176
4
Transmitter --- T.3 operation
5
Receiver --- T.3 operation
Receiver --- T.3 operation
6
Reserved for future T.3 operation features
7
Reserved for future T.3 operation features.
8
Reserved for future T.3 operation features.
9
Transmitter --- T.4 operation
Содержание KX-FP701ME
Страница 9: ...9 KX FP701ME 4 General Introduction 4 1 Error Message 4 1 1 Display 4 1 2 Report ...
Страница 11: ...11 KX FP701ME 6 Technical Descriptions 6 1 Connection Diagram ...
Страница 13: ...13 KX FP701ME 6 2 1 General Block Diagram ...
Страница 15: ...15 KX FP701ME 6 3 2 Memory Map ...
Страница 24: ...24 KX FP701ME 6 4 2 Block Diagram ...
Страница 26: ...26 KX FP701ME ...
Страница 41: ...41 KX FP701ME b Redundancy Compression Process Coding Mode This unit uses one dimensional MH format ...
Страница 68: ...68 KX FP701ME 11 2 2 Service Mode Settings Note The above values are the default values ...
Страница 75: ...75 KX FP701ME Countermeasure ...
Страница 76: ...76 KX FP701ME REFERENCE Test Mode P 60 ...
Страница 77: ...77 KX FP701ME REFERENCE Test Mode P 60 ...
Страница 78: ...78 KX FP701ME REFERENCE Test Mode P 60 ...
Страница 79: ...79 KX FP701ME REFERENCE Test Mode P 60 ...
Страница 80: ...80 KX FP701ME ...
Страница 81: ...81 KX FP701ME ...
Страница 82: ...82 KX FP701ME REFERENCE Test Mode P 60 ...
Страница 86: ...86 KX FP701ME ...
Страница 111: ...111 KX FP701ME ...
Страница 118: ...118 KX FP701ME I O and Pin No Diagram ...
Страница 120: ...120 KX FP701ME Other NG example while the power is ON and the LCD displays the following ...
Страница 121: ...121 KX FP701ME 12 5 5 2 NG Example ...
Страница 125: ...125 KX FP701ME 12 5 7 2 Troubleshooting Flow Chart ...
Страница 129: ...129 KX FP701ME 12 5 9 5 Check the HOOK Switch SW101 ...
Страница 130: ...130 KX FP701ME 12 5 10 CIS Contact Image Sensor Section REFERENCE 1 Test Mode P 60 Refer to Scanning Block P 27 ...
Страница 131: ...131 KX FP701ME 12 5 11 Thermal Head Section Note Refer to Thermal Head P 25 ...
Страница 132: ...132 KX FP701ME 13 Service Fixture Tools ...
Страница 135: ...135 KX FP701ME 14 2 DISASSEMBLY PROCEDURE 14 2 1 HOW TO REMOVE THE PAPER TRAY AND RECORDING PAPER SUPPORT ...
Страница 136: ...136 KX FP701ME 14 2 2 HOW TO REMOVE THE OPERATION PANEL BLOCK ...
Страница 137: ...137 KX FP701ME 14 2 3 HOW TO REMOVE THE OPERATION BOARD AND LCD ...
Страница 138: ...138 KX FP701ME 14 2 4 HOW TO REMOVE THE SEPARATION HOLDER AND EXIT ROLLER ...
Страница 139: ...139 KX FP701ME 14 2 5 HOW TO REMOVE THE IMAGE SENSOR CIS ...
Страница 140: ...140 KX FP701ME 14 2 6 HOW TO REMOVE THE THERMAL HEAD ...
Страница 141: ...141 KX FP701ME 14 2 7 HOW TO REMOVE THE PLATEN ROLLER AND BACK COVER ...
Страница 142: ...142 KX FP701ME 14 2 8 HOW TO REMOVE THE PICKUP ROLLER ...
Страница 143: ...143 KX FP701ME 14 2 9 HOW TO REMOVE THE CASSETTE LEVER ...
Страница 144: ...144 KX FP701ME 14 2 10 HOW TO REMOVE THE BOTTOM FRAME ...
Страница 145: ...145 KX FP701ME 14 2 11 HOW TO REMOVE THE DIGITAL ANALOG SENSOR BOARDS ...
Страница 146: ...146 KX FP701ME 14 2 12 HOW TO REMOVE THE POWER SUPPLY BOARD AND AC CORD ...
Страница 147: ...147 KX FP701ME 14 2 13 HOW TO REMOVE THE MOTOR BLOCK AND SEPARATION ROLLER ...
Страница 148: ...148 KX FP701ME 14 2 14 HOW TO REMOVE THE GEARS OF MOTOR BLOCK ...
Страница 149: ...149 KX FP701ME 14 2 15 INSTALLATION POSITION OF THE LEAD WIRES ...
Страница 156: ...156 KX FP701ME 15 2 2 4 Copying Note See Sensor Locations in Sensors and Switches P 32 REFERENCE Sensor Section P 128 ...
Страница 163: ...163 KX FP701ME 16 1 4 Power Supply Board 16 1 5 Interface Board ...
Страница 166: ...166 KX FP701ME 16 3 Test Chart 16 3 1 ITU T No 1 Test chart ...
Страница 167: ...167 KX FP701ME 16 3 2 ITU T No 2 Test Chart ...
Страница 168: ...168 KX FP701ME 16 3 3 Test Chart ...
Страница 169: ...169 KX FP701ME MEMO ...
Страница 180: ...180 KX FP701ME MEMO ...
Страница 188: ...188 KX FP701ME MEMO ...
Страница 194: ...194 KX FP701ME 20 1 2 Operation Panel Section ...
Страница 195: ...195 KX FP701ME 20 1 3 Back Cover Section ...
Страница 196: ...196 KX FP701ME ...
Страница 197: ...197 KX FP701ME 20 1 4 Upper Cabinet Section ...
Страница 198: ...198 KX FP701ME 20 1 5 Lower Cabinet Section ...
Страница 199: ...199 KX FP701ME 20 1 6 Gear Block Section ...
Страница 200: ...200 KX FP701ME 20 1 7 Screws ...
Страница 201: ...201 KX FP701ME 20 1 8 Accessories and Packing Materials ...