Panasonic Healthcare Co., Ltd., Medical Systems Business Unit
is certified for:
Quality management system: ISO9001
Medical devices quality management system: ISO13485
Panasonic Healthcare Co., Ltd., Medical Systems
Business Unit is certified for:
Environmental management system: ISO14001
DISTRIBUTED BY:
Features
Dimensions
Specifications
KM-RS16A1, KM-RS34A1 Series
KM-RS16A1
KM-RS34A1
Caution:
Panasonic guarantees the product under certain warranty conditions.
Panasonic in no way shall be responsible for any loss of content or damage to content.
• Appearance and specifications are subject to change without notice.
• Water condensation may sometimes appear on the glass doors, but this is normal and not a malfunction.
*1 Exterior dimensions of main cabinet only - see dimension drawings showing handles and other external
projections.
External dimensions (W x D x H)
*
1
Internal dimensions (W x D x H)
Effective capacity
Net weight
External cabinet
Internal cabinet
Insulation
Doors
Shelves
Access port
Lighting / Casters
Compressor
Refrigerant
Evaporator
Condenser
Defrosting
Defrosting heaters
Temperature control
Temperature display
High/Low temperature alarm system
Door ajar alarm
Options
800 x 465 x 1090 (mm)
31.5 x 18.3 x 42.9 (inch)
720 x 300 x 725 (mm)
28.3 x 11.8 x 28.5 (inch)
158 liters (5.6 cu.ft.)
71 kg (156 lbs.)
Hermetic type, 90 W
87 W
800 x 465 x 1800 (mm)
31.5 x 18.3 x 70.9 (inch)
720 x 350 x 1435 (mm)
28.3 x 13.8 x 56.5 (inch)
340 liters (12.0 cu.ft.)
100 kg (220 lbs.)
Hermetic type,160 W
101 W
Galvanised steel with baked-on finish
Stainless steel
Polyurethane foam
Sliding glass doors, double-glazing glass with
heat-reflective film
Hard steel wire
30mm ø on back wall
LED/2 casters
HFC
Fin & Tube, Forced-air circulation
Wire & Tube
Cyclical defrosting & evaporator temp. detection system
2˚C to 14˚C
Digital (1˚C increments)
±2˚C to ±14˚C from temperature setting value
Buzzer / door ajar lamp
Temperature recorder:
MTR-0621LH-PE/PA (recorder fixing: MPR-S30-PW)
MTR-G04C-PE/G04A-PA (recorder fixing: MPR-S7-PW)
Battery mounting box: KM-RPP01BB1W
Interface board: MTR-480-PW, MTR-L03-PW
DAQ system: MTR-5000-PW
Unit : mm (inch)
Printed in Japan 192-2013-09
http://panasonic.net/healthcare/biomedical/
220V-240V, 50Hz
220V, 60Hz
220V, 60Hz (for Saudi Arabia)
220V, 60Hz (for Taiwan)
110/115V, 60Hz
230/240V, 50Hz
220V, 50Hz/60Hz
220V, 50Hz/60Hz (for Saudi Arabia)
220V, 50Hz/60Hz (for Taiwan)
KM-RS16A1E
KM-RS16A1K
KM-RS16A1R
KM-RS16A1T
—
—
—
—
—
—
—
—
—
KM-RS34A1A
KM-RS34A1E
KM-RS34A1K
KM-RS34A1R
KM-RS34A1T
Model No.
Improved Energy Saving
Panasonic’s new cycle defrosting system achieved 15%* energy saving
compared to conventional models. This system observes the defrosting
condition after every cycle, and prevents temperature rises that are
caused by defrosting.
*The data is a measured example (set temp. 5°C, AT 23°C, 230V 50Hz, no load). Actual power
consumption will vary depending on the set and ambient conditions, loading and local voltage.
User Friendly Design
1. New Control Panel
- Newly designed for improved
operability, visibility, and
calibration
- Digital setup for easy and
secure operation
- Temperature alarm settings made on the control panel
2. LED Interior Light
The LED interior light
automatically turns on/off in
conjunction with the door
opening/closing. It can also be
controlled from the control
panel.
3. Double-Paned Glass with Heat-Reflective Film
The refrigerator doors constructed of double-paned glass with heat-
reflective film, allow easy loading and unloading of medical supplies
while preventing ultraviolet rays, which may damage stored items,
from entering the unit. Panasonic’s unique heat-reflective film blocks
the passage of radiant heat rays through the glass panels and keeps
the inside temperature from being adversely affected by excessive
amounts of heat.
Effective Temperature Control
1. Microprocessor Temperature Control
A thermistor sensor monitors temperature inside the chamber, and
microprocessor temperature control ensures that the set
temperature is maintained. Even if the door is opened and closed
frequently, the circulation fan ensures rapid temperature adjustment
to provide a highly reliable, stable preservation environment that is
not affected by ambient temperature.
2. Fan-Forced Air Circulation
The temperature stays even throughout the inside of the refrigerator
with the fan-forced air circulation system. No matter how the load is
distributed, every corner of the unit is immediately cooled with no
noticeable variation in temperature apparent inside the cabinet.
Enhanced Alarm and Safety Functions
1. Door Open Alarm
When the door is opened, the Door Open indicator lamp lights
automatically. After approx. 2 minutes, a buzzer alarm will sound
if the door has not been closed (settable from 0 to 15 minutes). If
the door remains open even after the buzzer is stopped, the buzzer
rings again after 30 minutes (settable from 0 to 60 minutes in
increments of 10 minutes).
2. Abnormal Temperature Alarm
If the inside temperature changes ±2˚C to ±14˚C from the set
temperature, the digital temperature display flashes, and a buzzer
sounds an alarm after 15 minutes (settable from 0 to 15 minutes).
450 (17.7)
8
(0.3)
800 (31.5)
720 (28.3) (inside)
405 (15.9)
90 (3.5)
725 (28.5)
638 (25.1)
325 (12.8)
1090 (42.9)
300
(11.8)
25
(1.0)
20 (0.8)
465 (18.3)
450 (17.7)
405 (15.9)
90 (3.5)
800 (31.5)
720 (28.3) (inside)
8
(0.3)
638 (25.1)
638 (25.1)
300
(11.8)
25
(1.0)
20 (0.8)
350
(13.8)
325 (12.8)
1435 (56.5)
1800 (70.9)
465 (18.3)