background image

Panasonic Healthcare Co., Ltd., Medical Systems Business Unit
is certified for:

Quality management system: ISO9001
Medical devices quality management system: ISO13485

 

Panasonic Healthcare Co., Ltd., Medical Systems 
Business Unit is certified for:

Environmental management system: ISO14001

 

DISTRIBUTED BY:

Features

Dimensions

Specifications

KM-RS16A1, KM-RS34A1 Series

KM-RS16A1

KM-RS34A1

Caution: 

Panasonic guarantees the product under certain warranty conditions. 

Panasonic in no way shall be responsible for any loss of content or damage to content.
• Appearance and specifications are subject to change without notice.
• Water condensation may sometimes appear on the glass doors, but this is normal and not a malfunction.
*1 Exterior dimensions of main cabinet only - see dimension drawings showing handles and other external 

projections.

External dimensions (W x D x H)

*

1

Internal dimensions (W x D x H)

Effective capacity
Net weight
External cabinet
Internal cabinet
Insulation

Doors

Shelves
Access port
Lighting / Casters
Compressor 
Refrigerant
Evaporator
Condenser
Defrosting
Defrosting heaters
Temperature control
Temperature display
High/Low temperature alarm system
Door ajar alarm
Options

800 x 465 x 1090 (mm)

31.5 x 18.3 x 42.9 (inch)

720 x 300 x 725 (mm)

28.3 x 11.8 x 28.5 (inch)

158 liters (5.6 cu.ft.)

71 kg (156 lbs.)

Hermetic type, 90 W

87 W

800 x 465 x 1800 (mm)

31.5 x 18.3 x 70.9 (inch)

720 x 350 x 1435 (mm)

28.3 x 13.8 x 56.5 (inch)

340 liters (12.0 cu.ft.)

100 kg (220 lbs.)

Hermetic type,160 W

101 W

Galvanised steel with baked-on finish 

Stainless steel 

Polyurethane foam 

Sliding glass doors, double-glazing glass with 

heat-reflective film 

Hard steel wire 

30mm ø on back wall 

LED/2 casters 

HFC 

Fin & Tube, Forced-air circulation 

Wire & Tube 

Cyclical defrosting & evaporator temp. detection system 

2˚C to 14˚C 

Digital (1˚C increments) 

±2˚C to ±14˚C from temperature setting value 

Buzzer / door ajar lamp

Temperature recorder: 

MTR-0621LH-PE/PA (recorder fixing: MPR-S30-PW) 

MTR-G04C-PE/G04A-PA (recorder fixing: MPR-S7-PW) 

Battery mounting box: KM-RPP01BB1W 

Interface board: MTR-480-PW, MTR-L03-PW 

DAQ system: MTR-5000-PW 

Unit : mm (inch)

Printed in Japan   192-2013-09

http://panasonic.net/healthcare/biomedical/

220V-240V, 50Hz
220V, 60Hz
220V, 60Hz (for Saudi Arabia)
220V, 60Hz (for Taiwan)
110/115V, 60Hz
230/240V, 50Hz
220V, 50Hz/60Hz
220V, 50Hz/60Hz (for Saudi Arabia)
220V, 50Hz/60Hz (for Taiwan)

KM-RS16A1E

KM-RS16A1K

KM-RS16A1R

KM-RS16A1T

          —

          —

          —

          —

          —

          —

          —

          —

          —
KM-RS34A1A

KM-RS34A1E

KM-RS34A1K

KM-RS34A1R

KM-RS34A1T

Model No.

Improved Energy Saving

Panasonic’s new cycle defrosting system achieved 15%* energy saving 
compared to conventional models. This system observes the defrosting 
condition after every cycle, and prevents temperature rises that are 
caused by defrosting.

*The data is a measured example (set temp. 5°C, AT 23°C, 230V 50Hz, no load). Actual power 

consumption will vary depending on the set and ambient conditions, loading and local voltage. 

User Friendly Design

1. New Control Panel

- Newly designed for improved 

operability, visibility, and 
calibration

- Digital setup for easy and 

secure operation

- Temperature alarm settings made on the control panel

2. LED Interior Light

The LED interior light 
automatically turns on/off in 
conjunction with the door 
opening/closing. It can also be 
controlled from the control 
panel.

3. Double-Paned Glass with Heat-Reflective Film

The refrigerator doors constructed of double-paned glass with heat- 
reflective film, allow easy loading and unloading of medical supplies 
while preventing ultraviolet rays, which may damage stored items, 
from entering the unit. Panasonic’s unique heat-reflective film blocks 
the passage of radiant heat rays through the glass panels and keeps 
the inside temperature from being adversely affected by excessive 
amounts of heat.

Effective Temperature Control

1. Microprocessor Temperature Control

A thermistor sensor monitors temperature inside the chamber, and 
microprocessor temperature control ensures that the set 
temperature is maintained. Even if the door is opened and closed 
frequently, the circulation fan ensures rapid temperature adjustment 
to provide a highly reliable, stable preservation environment that is 
not affected by ambient temperature.

2. Fan-Forced Air Circulation

The temperature stays even throughout the inside of the refrigerator 
with the fan-forced air circulation system. No matter how the load is 
distributed, every corner of the unit is immediately cooled with no 
noticeable variation in temperature apparent inside the cabinet.

Enhanced Alarm and Safety Functions

1. Door Open Alarm

When the door is opened, the Door Open indicator lamp lights 
automatically. After approx. 2 minutes, a buzzer alarm will sound 
if the door has not been closed (settable from 0 to 15 minutes).    If 
the door remains open even after the buzzer is stopped, the buzzer 
rings again after 30 minutes (settable from 0 to 60 minutes in 
increments of 10 minutes).

2. Abnormal Temperature Alarm

If the inside temperature changes ±2˚C to ±14˚C from the  set 
temperature, the digital temperature display flashes, and a buzzer 
sounds an alarm after 15 minutes (settable from 0 to 15 minutes).

450 (17.7)

8

(0.3)

800 (31.5)

720 (28.3) (inside)

405 (15.9)

90 (3.5)

725 (28.5)

638 (25.1)

325 (12.8)

1090 (42.9)

300

(11.8)

25 

(1.0)

20 (0.8)

465 (18.3)

450 (17.7)

405 (15.9)

90 (3.5)

800 (31.5)

720 (28.3) (inside)

8

(0.3)

638 (25.1)

638 (25.1)

300

(11.8)

25 

(1.0)

20 (0.8)

350

(13.8)

325 (12.8)

1435 (56.5)

1800 (70.9)

465 (18.3)

Отзывы: