Span
The system can output measurement values with a span (factor) multiplied.
Final measurement value = Span x measurement value + offset
Setting range
Function
Initial value
0.1000 to
+9.9999
Set a span in a range from
0.1000 to +9.9999.
The display limit of the measurement value is ±95.000. Make sure that the setting
value does not exceed the display limit.
● Setting Procedure
1
Display the "Data Processing Setting"
screen while the system is in setting mode.
2
Press the [ENTER] key. The "Average
Time" screen will be displayed.
3
Press the [DOWN] key twice. The "Span"
screen will be displayed.
4
Pre
ss the [ENTER] key. The present
span will be displayed. The leftmost digit
will be selected.
5
Press the [UP]/[DOWN] keys together to
change the selected digit. After all the
changed digits have blinked the sign can
be changed. For details, refer to page 3-8
"Making Setting Value Changes."
Output
Final meas. value
Meas. value
Spanned meas. value
Offset value
Measurem
ent range
0
Center point of measurement