5-3-6 Analog Scaling (
)
The judgment value (JUDGE.V) can be converted to a current (4 to 20mA) and output as ana-
log output.
Analog scaling allows you to select the method of setting the scaling upper limit value and scal-
ing lower limit value for analog output.
Analog scaling
Function
Default (DEFALT)
Output an analog current according to the maximum stroke of the sensor head.
Free (FREE)
You can set the upper limit value and lower limit value of analog output.
To set the upper limit value and lower limit value, refer to "
5-3-7 Scaling Upper
Limit Value / Scaling Lower Limit Value
".
■ When default (DEFALT) is set
The upper limit value varies by sensor head.
The lower limit value is "0.0000", regardless of the sensor head.
20mA
4mA
Judgment value (JUDGE.V)
Analog current output
Lower limit value
(0mm)
Upper limit value
(10mm)
●
Analog output specifications
Current output range
4 to 20mA
Resolution
0.3μA
Error output
0mA
Linearity
±0.25% F.S.
Maximum load impedance
250Ω max.
Содержание HG-S Series
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2019 2 MEMO ...
Страница 7: ...1 1 Chapter 1 INTRODUCTION 1 1 Safety Cautions 1 2 1 2 Safety Information 1 2 ...
Страница 44: ... Panasonic Industrial Devices SUNX Co Ltd 2019 3 24 MEMO ...
Страница 72: ... Panasonic Industrial Devices SUNX Co Ltd 2019 4 28 MEMO ...
Страница 75: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 3 MEMO ...
Страница 174: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 102 MEMO ...
Страница 175: ...6 1 Chapter 6 SPECIFICATIONS 6 1 Specifications 6 2 6 2 Dimensions 6 7 ...
Страница 188: ... Panasonic Industrial Devices SUNX Co Ltd 2019 6 14 MEMO ...
Страница 198: ... MEMO ...