FUNCTION SETTINGS
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
5-55
5-3-3 External Input (
)
You can select from four combinations for the signals that are input into input 1 / input 2 / input 3
of external input.
External input setting combinations are shown below.
External input
Input signal combination
Input 1 (Pink)
Input 2 (Violet)
Input 3 (Pink / Violet)
Preset / Reset / Trigger (P/R/T )
Preset
Reset
Trigger
Bank A / Bank B / Preset (BANK/P)
Bank A
Bank B
Preset
Bank A / Bank B / Reset (BANK/R)
Bank A
Bank B
Reset
Bank A / Bank B / Trigger (BANK/T)
Bank A
Bank B
Trigger
●
Minimum input time
The minimum input time depends on the input type.
<Preset input>
ON
OFF
Preset input
Minimum 20ms
Preset
Preset release
Minimum 20ms
Minimum 1.5 sec.
<Reset input>
ON
OFF
Reset input
Minimum 20ms
Minimum 20ms
<Trigger input>
Trigger input
ON
OFF
Minimum 2ms Minimum 2ms
<Bank A / B input>
ON
OFF
ON
OFF
Bank A
Bank
Bank B
Minimum 20ms
20ms (*1)
Bank 1
Bank 3
Minimum 20ms (*1)
Maximum 8ms (*2)
20ms (*1)
*1: Minimum of 50ms when bank save is set to "ALL".
*2: If more than 8ms elapses, data may be read from bank 1 and then bank 2.
<Reference>
●
For controller I/O circuit diagrams, refer to
.
●
.
Содержание HG-S Series
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2019 2 MEMO ...
Страница 7: ...1 1 Chapter 1 INTRODUCTION 1 1 Safety Cautions 1 2 1 2 Safety Information 1 2 ...
Страница 44: ... Panasonic Industrial Devices SUNX Co Ltd 2019 3 24 MEMO ...
Страница 72: ... Panasonic Industrial Devices SUNX Co Ltd 2019 4 28 MEMO ...
Страница 75: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 3 MEMO ...
Страница 174: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 102 MEMO ...
Страница 175: ...6 1 Chapter 6 SPECIFICATIONS 6 1 Specifications 6 2 6 2 Dimensions 6 7 ...
Страница 188: ... Panasonic Industrial Devices SUNX Co Ltd 2019 6 14 MEMO ...
Страница 198: ... MEMO ...