Panasonic GA-311 Скачать руководство пользователя страница 1

CAUTIONS

2

٨
٨
٨
٨
٨

٨

٨

٨

٨

٨
٨
٨
٨

٨

٨

٨

This product has been developed / produced for industrial use.
Make sure that the power supply is off while wiring or adding the units.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
In case noise generating equipment (switching regulator, inverter motor, 
etc.) is used in the vicinity of this product, connect the frame ground 
(F.G.) terminal of the equipment to an actual ground.
If power is supplied from a commercial switching regulator, ensure that 
the frame ground (F.G.) terminal of the power supply is connected to an 
actual ground.
Do not use during the initial transient time (0.5 sec.) after the power 
supply is switched on.
Do not run the wires together with high-voltage lines or power lines or put 
them in the same raceway. This can cause malfunction due to induction.
Be sure to use the optional quick-connection cable for amplifier 
connection. Furthermore, extension up to 100m (50m: 5 to 8 units are 
connected in cascade, 20m: 9 to 16 units are connected in cascade) is 
possible with 0.3mm

2

 or more, cable. However, in order to reduce noise, 

make the wiring as short as possible. 
Take care that when the cable is extended, the residual voltage rises.
Do not shorten or lengthen the sensor head cable.

This sensor is suitable for indoor use only.
Do not use the sensor at places having intense vibrations, as this can 
cause malfunction. 
Take care that the sensor does not come in direct contact with water, oil, 
grease, organic solvents, such as, thinner etc., or strong acid, and alkaline.
Make sure that the sensing end is not covered with metal dust, scrap or 
spatter. It will result in malfunction.
Take care that stress by forcible bending or pulling is not applied directly 
to the sensor head cable joint.

SPECIFICATIONS

1

Cable (Note 4)

Connector attached oil resistant high frequency coaxial cable, 3m long

 [Spatter resistant cable for 

GH-F8SE

 (Outer shield: Fluorine resin)]

Enclosure:

SUS303

Sensing part: 

PVC

Enclosure:

       SUS303 

Sensing part:

ABS

Enclosure:

SUS303

Sensing part: 

PAR

Enclosure:

SUS303

Sensing part: 

ABS

Enclosure:

SUS303

Sensing part: 
Fluorine resin

Material

Temp. characteristic (Note 3)

Within

r

5%

Within

r

7%

Within

r

4%

-10 to +60

͠

, Storage: -20 to +70

͠

Ambient temperature 

IP50 (IEC)

IP67 (IEC), IP67g (JEM)

Protection

0.04mm or less

0.07mm or less

0.05mm or less

Hysteresis (Note 2) 

Iron 10

˜

10

˜

t1mm

Stable sensing range (Note 1)

0 to 0.8mm

0 to 0.6mm

0 to 2.0mm

0 to 1.0mm

Max. operation distance (Note 1)

1.8mm

1.2mm

4.0mm

2.4mm

GH-3SE

GH-F8SE

GH-2SE

GH-8SE

GH-5SE

Spatter-resistant type

Cylindrical type

GA-311

Applicable amplifier

Model No. 

Item

T y p e

Iron 5

˜

5

˜

t1mm

Standard sensing object

35 to 85% RH, Storage: 35 to 85% RH

Ambient humidity

15g approx.

35g approx.

40g approx.

55g approx.

Weight

٨

Sensor head

Notes: 1)

2)
3)

4)

The stable sensing range represents the sensing range for which the sensor 
can satisfy all the given specifications with the standard sensing object.
The maximum operation distance represents the maximum distance for 
which the sensor can detect at +20

͠

 constant ambient temperature.

Usage within the stable sensing range is recommended for accurate 
sensing applications.
Value is given for the stable sensing range. 
The value represents the variation in the operation distance, that has been 
set within the stable sensing range at +20

͠

, for an ambient temperature 

drift from 0 to +55

͠

. (The value is for sensor head on its own.)

The length of the sensor head cable cannot be changed. 

Notes: 1)

2)

3)

50mA, if five, or more, amplifiers are connected in cascade.
The value represents the variation in the operation distance, that has been 
set within the stable sensing range at +20

͠

, for an ambient temperature 

drift from 0 to +55

͠

. (The value is for amplifier on its own.)

The cable for amplifier connection is not supplied as an accessory. Make 
sure to use the optional quick-connection cable given below. 
Main cable (3-core): 

CN-73-C1

(cable length 1m), 

CN-73-C2

(cable length 2m)

CN-73-C5

(cable length 5m)

Sub-cable (1-core) :

CN-71-C1

(cable length 1m), 

CN-71-C2

(cable length 2m)

CN-71-C5

(cable length 5m)

25mA or less

Current consumption 

12 to 24V DC

r

10 %

ޓ

Ripple P-P10 % or less

Supply voltage

T y p e

Item

GA-311

Output

NPN open-collector transistor 

Maximum sink current: 100mA

Applied voltage: 30V DC or less (between output and 0V)

Residual voltage: 1V or less [at 100mA (Note 1) sink current]

18-turn potensiometer 

Sensitivity adjuster

Orange LED (lights up when the output is ON)

Operation indicator

Max. response frequency

3.3kHz

Normally open / closed  Selectable with the operation mode switch

Output operation

Incorporated

Short-circuit protection

Red LED (lights up when the sensor head is disconnected or mis-contacted)

Disconnection alarm indicator

Ambient temperature

-10 to +60

͠

 (if 4 to 7 units are connected in cascade: -10 to +50

͠

,

if 8 to 16 units are connected in cascade: -10 to +45

͠

) (No dew con-

densation or icing allowed),  Storage: -20 to +70

͠

Temp. characteristic (Note 2)

Within

r

5%

35 to 85% RH, Storage: 35 to 85% RH

Ambient humidity

Enclosure: Heat-resistant ABS, Case cover: Polycarbonate

Material

15g approx.

Weight

٨

Amplifier

MOUNTING

3

Be sure to use a sensor head and amplifier as a set.

Disconnection method

Ԙ

Pressing the projection on the sensor 
head connector, pull out the connector.

Connection method

Ԙ

ԙ

Insert the the sensor head connector into 
the connector inlet till a click is felt.
Fit the cover on the connector. 

٨

Connection of sensor head

Ԙ

Sensor head 
connector part

Cover

ԙ

Projection

Take care that if the connector is pulled out without pressing the projection, the pro-
jection may break. Do not use a sensor head connector whose projection has bro-
ken. Furthermore, do not pull by holding the cable, as this can cause a cable-break.

Note:

Ԙ

ԙ

Fit the rear part of the mounting section of the 
amplifier on a 35mm width DIN rail.
Press down the rear part of the mounting section 
of the unit on the 35mm width DIN rail and fit the 
front part of the mounting section to the DIN rail.

How to mount the amplifier

Take care that if the front part is lifted without pushing the amplifier forward, the 
hook on the rear portion of the mounting section is likely to break.

Note:

How to remove the amplifier

Ԙ
ԙ

Push the amplifier forward.
Lift up the front part of the amplifier to remove it.

٨

Mounting of amplifier

Ԙ

35mm width DIN rail

ԙ

Ԙ

ԙ

Do not tighten it with excessive strength.

Note:

٨

Mounting of sensor head

The tightening torque 
for mounting should be 
as given right.
Furthermore, be sure 
to use a set screw with 
a cup-point end. 

0.17N

m

4 or more

0.78N

m

GH-3SE

5 or more

0.59N

m

GH-5SE

5 or more

GH-8SE
GH-F8SE

Model No.

A

mm

Tightening torque

3 or more

0.17N

m

GH-2SE

Set screw (M3)
(Cup-point end)

A

Mounting with a set screw

Influence of surrounding metal

The surrounding metal 
will affect the sensing 
performance. Keep the 
minimum distance 
specified in the table 
right.

4

GH-3SE

5

GH-5SE

9

GH-8SE
GH-F8SE

Model No.

B

mm

3

GH-2SE

B

Background metal

٨
٨

Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products 
which meet laws and standards, such as OSHA, ANSI or IEC etc., for 
personnel protection applicable in each region or country.

WARNING

Thank you very much for purchasing Panasonic products. Please read this 
Instruction Manual carefully and thoroughly for the correct and optimum 
use of this product. Kindly keep this manual in a convenient place for quick 
reference.

INSTRUCTION MANUAL

Amplifier-separated Type Inductive Proximity Sensor

Amplifier

GA-311

Sensor head 

GH-

غ

SE

MJE-GA311 No.0034-54V

Ramco National

www.PanasonicSensors.com

1-800-280-6933

Отзывы: