INSTRUCTION MANUAL
Digital Fiber Sensor Amplifier
FX-551
Series
ME-FX551 No.0058-72V
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the correct and optimum
use of this product.
Kindly keep this manual in a convenient place for quick reference.
WARNING
●
Never use this product as a sensing device for personnel protection.
●
In case of using sensing devices for personnel protection, use products which
meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel
protection applicable in each region or country.
This product is not equipped with an automatic interference prevention function.
By setting different frequencies, interference can be prevented for up to four units.
For the setting method, refer to <PRO3> in “
12
PRO MODE
.”
1
INTENDED PRODUCTS FOR CE MARKING
●
This product complies with the following standards / regulations.
<EU Directive>
EMC Directive
2
PART DESCRIPTION
UP key
•
Teaching
•
Threshold value fine
adjustment
•
Select setting items
SET key
•
Teaching
•
Confirm setting
contents
DOWN key
•
Teaching
•
Threshold value fine
adjustment
•
Select setting items
MODE key
•
Select modes
•
Cancel during setting
Digital display (Green / Red)
MODE indicator: PRO (Yellow)
・
Lights when setting PRO mode
MODE indicator: L / D (Yellow)
・
Lights when setting SENSING OUTPUT OPERATION MODE
Sensing output operation
indicator (Orange)
MODE indicator: CUST (Yellow)
・
Lights when setting LIGHT SENSITIVITY SETTING MODE
<Reference>
Pressing down SET key + MODE key for 3 sec : Set key lock or release key lock
3
MOUNTING
How to mount
1.
Fit the rear part of the mounting section of
the amplifier on a DIN rail.
2.
Press down the rear part of the mounting
section of the unit on the DIN rail and fit the
front part of the mounting section to the DIN
rail.
2.
Press down
1.
Fit
35mm width DIN rail
How to remove
1.
Push the amplifier forward.
2.
Lift up the front part of the amplifier to remove
it.
2.
Lift up
1.
Push forward
How to connect the fiber cable
● Mount the fiber cables in the state power is not supplied.
● Be sure to fit the attachment to the fibers first before inserting the fibers to the
amplifier. For details, refer to the instruction manual enclosed with the fibers.
● Insert the fiber cables slowly into the inlets until they stops. Excessive force may
damage the product.
1.
Snap the fiber lock lever down till it stops
completely.
2.
Insert the fiber cables slowly into the inlets
until they stops. (Note)
3.
Return the fiber lock lever to the original
position till it stops.
1.
Snap
2.
Insert
3.
Return
Fiber for receiver
Fiber lock lever
Fiber for emitter
Note: With the coaxial reflective type fiber, insert the single core fiber cable into the beam-emitting inlet “P” and the
multi-core fiber cable into the beam-receiving inlet.
If they are inserted in reverse, the sensing performance will deteriorate.
4
INSTALL MORE AMPLIFIER OF SERIES CONNECTION TYPE
(Connection type only)
●
Make sure that the power supply is OFF while adding or removing the series
connection type.
●
This product is not equipped with an automatic interference prevention function.
By setting different frequencies, interference can be prevented for up to four
units. For the setting method, refer to <PRO3> in “
12
PRO MODE
.”
●
In case 2 or more the series connection types are connected in cascade, make
sure to mount them on a DIN rail.
● In case installing additional amplifier of series connection type, the maximum
15 the series connection types using sub cables (optional) can be added to an
amplifier using a main connection cable. (optional)
●
When connecting 2 or more the series connection types in cascade, use the sub
cable (optional) for the second series connection type onwards.
For mounting and removing the amplifier, refer to “
3
MOUNTING
.”
How to cascade
1.
Mount the amplifiers, one by one, on
the DIN rail.
2.
Slide the amplifiers next to each other,
and connect the quick-connection
cables.
3.
Mount the end plates
MS-DIN-E
(optional) at both the ends to hold the
amplifiers between their flat sides.
4.
Tighten the screws to fix the end
plates.
How to Remove
1.
Loosen the screws of the end plates.
2.
Remove the end plates.
3.
Slide the amplifiers and remove them
one by one.
Slide
Slide
Sub cable (Optional)
Main cable (Optional)
End plate
MS-DIN-E
(Optional)
End plate
MS-DIN-E
(Optional)
5
I/O CIRCUIT DIAGRAMS
< NPN output type >
Main circuit
(Brown) +V (Note)
(Black) Sensing output
(Blue) 0V (Note)
+
‒
12 to 24V DC
+10
‒15
%
Load
< PNP output type >
Main circuit
(Brown) +V (Note)
(Black) Sensing output
(Blue) 0V (Note)
+
‒
12 to 24V DC
+10
‒15
%
Load
Note: The quick-connection sub cable does not incorV (brown) and 0V (blue). The power is supplied from the
connector of the main cable.
< FX551□ terminal arrangement >
2
3
1
Terminal No.
Terminal name
1
+V
2
Sensing output
3
0V
6
OPERATION PROCEDURE
The changed settings are not stored if turning the power OFF while setting.
Therefore, confirm the settings by pressing the SET key before turning the power
OFF.
●
When turning ON the power, RUN mode is displayed and the digital display shows
the threshold value (green) and the incident light intensity (red).
• Displays threshold value (green) and incident light intensity (red).
•
Teaching, threshold value fine adjustment and key lock function can
be set.
• For setting method of each function, refer to “
7
TEACHING MODE
,”
“
8
THRESHOLD VALUE FINE ADJUSTMENT FUNCTION
,” or “
9
KEY LOCK FUNCTION
.”
• Select either Light-ON or Dark-ON.
• For the setting, refer to “
10
SENSING OUTPUT OPERATION MODE
.”
• The default setting is “
” (Light-ON).
• Displays light sensitivity setting and enables its setting.
• For detailed information, refer to “
11
LIGHT SENSITIVITY SETTING
MODE
.”
•
Detailed settings can be set for maximizing the performance of
individual functions.
• For setting items and setting method, refer to “
12
PRO MODE.”
<RUN mode>
<Sensing output operation mode>
<Light sensitivity setting mode>
<PRO mode>
<RUN mode>