)RUPRXQWLQJDQGUHPRYLQJWKHDPSOL¿HUUHIHUWR³
MOUNTING
.”
How to cascade
1.
0RXQWWKHDPSOL¿HUVRQHE\RQH
on the DIN rail.
2.
6OLGHWKHDPSOL¿HUVQH[WWRHDFK
other, and connect the quick-
connection cables.
3.
Mount the end plates
MS-DIN-E
(optional) at both the ends to hold
the amplifiers between their flat
sides.
4.
7LJKWHQWKHVFUHZVWR¿[WKHHQG
plates.
+RZWR5HPRYH
1.
Loosen the screws of the end
plates.
2.
Remove the end plates.
3.
Slide the amplifiers and remove
them one by one.
Slide
Communication
window
Slide
Main cable
(Optional)
Sub cable
(Optional)
End plate
MS-DIN-E
(Optional)
End plate
MS-DIN-E
(Optional)
5
I/O CIRCUIT DIAGRAMS
<FX-502>
Load
+
-
12 to 24V DC
%
Main circuit
(Brown) +V (Note)
(Black) Sensing output 1
(White) Sensing output 2 / External input
(Blue) 0V (Note)
<FX-502P>
Main circuit
(Brown) +V (Note)
(Blue) 0V (Note)
(Black) Sensing output 1
(White) Sensing output 2 / External input
+
-
12 to 24V DC
%
Load
Note: The quick-connection sub cable does not incorV (brown) and 0V (blue). The power is supplied from
the connector of the main cable.
7HUPLQDODUUDQJHPHQW!
2
3
1
4
Terminal No.
Terminal name
1
+V
2
Sensing output 1
3
Sensing output 2 / External input
4
0V
6
OPERATION PROCEDURE
Ɣ
The sensing output can be switched to sensing output 1 or sensing output 2
by holding down the mode key.
Ɣ
The changed settings are not stored if turning the power OFF while setting.
7KHUHIRUHFRQ¿UPWKHVHWWLQJVE\SUHVVLQJWKH6(7NH\EHIRUHWXUQLQJWKH
power OFF.
Ɣ
When turning ON the power, RUN mode is displayed and the digital display
shows the threshold value (green) and the incident light intensity (red).
• Displays threshold value (green) and incident light intensity (red).
•
7HDFKLQJWKUHVKROGYDOXH¿QHDGMXVWPHQWDQGNH\ORFNIXQFWLRQ
can be set.
• For setting method of each function, refer to “
TEACHING
MODE
,” “
THRESHOLD VALUE FINE ADJUSTMENT FUNC-
TION
,” or “
KEY LOCK FUNCTION
.”
<RUN mode>
• Select either Light-ON or Dark-ON.
• For the setting, refer to “
SENSING OUTPUT OPERATION
MODE
.”
• The default setting is “
” (Light-ON).
<Sensing output operation mode>
• An item set in CUSTOM mode (Response time setting, Emission
power setting and Hysteresis setting) is displayed.
• For details, refer to “
CUSTOM MODE
.”
• The default setting is “
” (response time setting).
<CUSTOM mode>
• Advanced setting can be done.
• For the setting, refer to “
PRO MODE
.”
<PRO mode>
<RUN mode>
INSTRUCTION MANUAL
'LJLWDO)LEHU6HQVRU$PSOL¿HU
FX-502
Ƒ
MJE-FX502C No.0068-84V
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the correct and
optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
WARNING
Ɣ
Never use this product as a sensing device for personnel protection.
Ɣ
In case of using sensing devices for personnel protection, use products which
meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel
protection applicable in each region or country.
1
INTENDED PRODUCTS FOR CE MARKING
Ɣ
This product complies with the following standards / regulations.
(8'LUHFWLYH!
EMC Directive
<Standards in US / Canada>
ANSI/UL 60947-5-2, CAN/CSA C22.2 No.14
5HJXODWLRQVLQ.RUHD!
6*6:
Ɣ
Caution about UL recognition
In case requiring conformity of UL listing mark or C-UL listing mark, USe class
2 power supply unit.
Ɣ
&RQWDFWIRU&(
3DQDVRQLF0DUNHWLQJ(XURSH*PE+3DQDVRQLF7HVWLQJ&HQWHU
:LQVEDPEXUJ*HUPDQ\
2
PART DESCRIPTION
Digital display
*UHHQ5HG
UP key
• Teaching
• Threshold value
¿QHDGMXVWPHQW
• Select setting items
MODE key
• Select Modes
• Cancel during setting
• Select sensing output 1/2
by pressing long
SET key
• Teaching
• Confirm setting
contents
DOWN key
• Teaching
•
7KUHVKROGYDOXH¿QH
adjustment
• Select setting items
Sensing output 2
selection indicator
<HOORZ
Sensing output 1
selection indicator
<HOORZ
Sensing output 1
operation indicator
(Orange)
Sensing output 2
operation indicator
(Orange)
02'(LQGLFDWRU352<HOORZ
02'(LQGLFDWRU/'<HOORZ
02'(LQGLFDWRU&867<HOORZ
Pressing down SET key + MODE key for 3 sec : Set key lock or release key lock
3
MOUNTING
How to connect
1.
Fit the rear part of the mounting sec-
WLRQRIWKHDPSOL¿HURQD',1UDLO
2.
Press down the rear part of the
mounting section of the unit on the
DIN rail and fit the front part of the
mounting section to the DIN rail.
+RZWRUHPRYH
1.
Push the controller forward.
2.
/LIWXSWKHIURQWSDUWRIWKHDPSOL¿HU
to remove it.
2.
Lift up
1.
Push forward
2.
Press down
1.
Fit
35mm width DIN rail
+RZWRFRQQHFWWKH¿EHUFDEOH
%HVXUHWR¿WWKHDWWDFKPHQWWRWKH¿EHUV¿UVWEHIRUHLQVHUWLQJWKH¿EHUVWRWKH
DPSOL¿HU)RUGHWDLOVUHIHUWRWKHLQVWUXFWLRQPDQXDOHQFORVHGZLWKWKH¿EHUV
1.
Snap the fiber lock lever down till it
stops completely.
2.
,QVHUWWKH¿EHUFDEOHVVORZO\LQWRWKH
inlets until they stops. (Note)
3.
Return the fiber lock lever to the
original position till it stops.
Note:
:LWKWKHFRD[LDOUHÀHFWLYHW\SH¿EHUVXFKDV
FD-G4
or
FD-FM2
LQVHUWWKHVLQJOHFRUH¿EHUFDEOHLQWRWKH
EHDPHPLWWLQJLQOHW³3´DQGWKHPXOWLFRUH¿EHUFDEOH
into the beam-receiving inlet. If they are inserted in
reverse, the sensing performance will deteriorate.
Fiber lock lever
Fiber for
receiver
1.
Snap
3.
Return
2.
Insert
Fiber for emitter
4
INSTALL MORE AMPLIFIER OF SERIES CONNECTION TYPE
Ɣ
Make sure that the power supply is OFF while adding or removing the series connection type.
Ɣ
In case 2 or more the series connection types are connected in cascade, make
sure to mount them on a DIN rail.
Ɣ WKHVHULHVFRQQHFWLRQW\SHVXVLQJVXEFDEOHVFDQEHDGGHGWRDQDPSOL¿HU
using a main connection cable.
Ɣ
When connecting 2 or more the series connection types in cascade, use the
sub cable (optional) for the second series connection type onwards.
<Reference>