Use  this  unit  only  in  the  manner  intended  by  the  manufacturer.  If  you  have  any  questions, 
contact  the  manufacturer. 

Before  servicing  or  cleaning  unit,  switch  power  off  at  service  panel  and  lock  the  service 
disconnecting  means  to  prevent  power  from  being  switch  on  accidentally.  When  the  service 
disconnecting  means  cannot  be  locked,  securely  fasten  a  prominent  warning  device,  such 
as  a  tag,  to  the  service  panel.

Installation  work  and  electrical  wiring  must  be  done  by  qualified  person(s)  in  accordance  with
all  applicable  codes  and  standards,  including  fire-rated  construction.

When  cutting  or  drilling  into  wall  or  ceiling,  do  not  damage  electrical  wiring  and  other 
hidden  utilities.

Ducted  fans  must  always  be  vented  to  the  outdoors.

If  this  unit  is  to  be  installed  over  a  tub  or  shower,  it  must  be  marked  as  appropriate  for  the 
application  and  be  connected  to  a  GFCI  (Ground  Fault  Circuit  Interrupter)  -  protected  branch 
circuit. 

These  models  are  UL  listed  for  tub  and  shower  enclosures.

For  Your  Safety

To  reduce  the  risk  of  injury,  loss  of  life,  electric  shock,  fire,  malfunction,  and  damage  to 
equipment  or  property,  always  observe  the  following  safety  precautions.

The  following  symbol  word  panels  are  used  to  classify  and  describe  the  level  of  hazard,  injury,  and 
property  damage  caused  when  the  denotation  is  disregarded  and  improper  use  is  performed.

Explanation  of  symbol  word  panels

To  reduce  the  risk  of  fire,  electric  shock  or  injury  to  persons,  observe  the  following  :

Denotes  a  potential  hazard  that  could  result  in  serious 
injury  or  death.

Denotes  a  hazard  that  could  result  in  minor  injury.

The  following  symbols  are  used  to  classify  and  describe  the  type  of  instructions  to  be  observed.

This  symbol  is  used  to  alert  users  to  a  specific  operating  procedure  that  must  not  be 
performed.

This  symbol  is  used  to  alert  users  to  a  specific  operating  procedure  that  must  be  followed 
in  order  to  operate  the  unit  safely.

Sufficient  air  is  needed  for  proper  combustion  and  exhausting  of  gases  through  the  flue
(chimney)  of  fuel  burning  equipment  to  prevent  back  drafting.  Follow  the  heating  equipment
manufacturer’s  guideline  and  safety  standards  such  as  those  published  by  the  National  Fire 
Protection Association  (NFPA),  and  the American  Society  for  Heating,  Refrigeration  and Air 
Conditioning  Engineers  (ASHRAE)  and  the  local  code  authorities.

CAUTION

WARNING

WARNING

Содержание FV-05VS3

Страница 1: ...FV 05VS3 FV 08VS3 FV 10VS3 7 2 3 5 6 Back cover Back cover Back cover Cleaning 4 4 4 4 5 6 Joist Mounting Wall Mounting ...

Страница 2: ...d damage to equipment or property always observe the following safety precautions The following symbol word panels are used to classify and describe the level of hazard injury and property damage caused when the denotation is disregarded and improper use is performed Explanation of symbol word panels To reduce the risk of fire electric shock or injury to persons observe the following Denotes a pot...

Страница 3: ...ot kink the supply wiring Provide make up air for proper ventilation For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors Not for use in cooking area Fig B The special purpose or dedicated parts such as mounting fixtures must be used if such parts are provided 3 Do not install the unit where ducts are configured as shown in Fig A Do not install with a ...

Страница 4: ...4 5 ST4 2X30 Long screw Grille 1 2 1 Installation instructions Warranty sheet 3 3 8 85 7 8 22 5 3 3 4 94 10 1 4 260 ...

Страница 5: ...ion box knock out hole Fig 3 Fig 3 Fig 1 Adaptor Damper Mount junction box cover carefully so that lead wires are not pinched Neutral to white Tape Accessory screws Tape Suspension bracket Live to black Note For wiring details please refer to the wiring diagram Joist 2 Long screws ST4 2x30 2 Long screws ST4 2x30 Fig 2 Suspension bracket Joist Joist Squeeze 5 Squeeze the circular duct to fit the ad...

Страница 6: ... work 4 Finish the wall work Wall hole should be aligned with the inside edge of the flange Fig 8 4 Long screws ST4 0 x 30 Wall Wall Stub Stud WALL 1 Before installation remove the tape from damper and adaptor and check that the damper can open and close smoothly Then remove the accessory screws from suspension bracket Fig 1 of page 5 Fig 7 After finishing the ceiling job fill gap between flange a...

Страница 7: ...ve dust and dirt from fan body using a vacuum cleaner Fig 11 1 Remove grille Squeeze mounting springs and pull down carefully Fig 9 4 Using a cloth dampened with kitchen detergent remove any dirt from fan body Wipe dry with clean cloth Fig 12 5 Replace grille WARNING CAUTION Fig 10 Fig 11 Fig 12 Fig 9 ...

Страница 8: ...at loss and gain Fig 13 Loose fill or batt insulation can be placed directly over the fan housing in the attic Our fans and fan light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitor s fan light combination Our efficient cool running motors and our fluorescent lamps do not create enough ambient heat to be subjected to these lim...

Отзывы: