Properly insulate the area around the
fan to minimize building heat loss and
gain. (Fig.25) Loose fill or batt insulation
can be placed directly over the fan
housing in the attic.
Panasonic fan and fan/light combination
units do not create the excessive heat
that is a common problem with recessed
light fixtures or some other fan/light
combinations.
Our efficient, cool-running motors do
not create enough ambient heat to be
subjected to these limitations.
The ducting from this fan heater to the
outside of the building has a strong
effect on the air flow, noise and energy
use of the fan.
Use the shortest, straightest duct routing
possible for best performance, and avoid
installing the fan with smaller ducts than
recommended. Insulation around the
ducts can reduce energy loss and inhibit
mold growth. Fans installed with existing
ducts may not achieve their rated air flow.
Model No.
Air direction
Exhaust
&
Circulation
Exhaust
&
Circulation
Voltage
[V]
Frequency
[Hz]
Heat
Vent
Light
Power
[W]
Weight
[Ib. (k )]
Vent
FV-0511VH1
FV-0511VHL1
50
1480 (25 °C)
1680 (0 °C)
1480 (25 °C)
1680 (0 °C)
10
4.7
7.4
12.4
4.7
7.7
12.0
110
80
60
120
60
120
110
50
80
14.3
(6.5)
15.1
(6.9)
HVI Certified performance based on HVI Procedures 915, 916, and 920. (Ventilating mode only)
Air volume
at 0.1
″
WG
[CFM]
Noise
[sone]
Vent
<0.3
<0.3
0.7
<0.3
<0.3
0.7
PRACTICAL GUIDE TO INSTALLATION
PRODUCT SERVICE
SPECIFICATIONS
Panasonic Canada Inc.
5770 Ambler Drive, Mississauga, Ontario L4W 2T3
www.panasonic.com
Fig.25
lnsulation
4 inches or 6 inches roof jack, wall cap,
or soffit vent with backdraft damper
Mechanically connect duct
to termination and seal with
mastic or approved foil
faced tape
2-3 ft straight run before elbow
Short piece of flexible
duct helps alignment and
absorbs sound.
Clamps plus mastic or
approved foil faced tape
at all flex joints
Foil tape tightly covers
all metal duct joints
(glue PVC joints)
ln attic installation,
caulk box to drywall