PLEASE READ PRIOR TO INSTALLING THIS FAN CONTINUED

These fans are also built to take care of the homeowner’s spot ventilation needs when the room is 
occupied. The basic fan models allow a choice of three speeds. When fans are equipped with the optional 
Multi-Speed module, these models kick up to a maximum level of 150 CFM for the FV-11-15VKL1 and 110 
CFM for the FV-05-11VKSL1 and FV-05-11VKL1 either when the switch is turned on or activated by the 
optional Condensation Sensor module or the optional Motion Sensor module.

A High/Low Delay Timer, located inside the fan unit, is utilized to return the fan back to the pre-set
Continuous ventilation mode. The installer needs to consult with the homeowner for the desired
setting on the timer (0 - 60 minutes) and make the adjustments during the installation.

CustomVent Multi-Speed module (Lower Setting).   ASHRAE 62.2-2010

(sq.feet)

<1,000

1,500
2,000
2,500
3,000
3,500
4,000
4,500
5,000
5,500
6,000
6,500
7,000

33
38
43
48
53
58
63
68
73
78
83
88
93

40
45
50
55
60
65
70
75
80
85
90
95

100

48
53
58
63
68
73
78
83
88
93
98

103
108

55
60
65
70
75
80
85
90
95

100
105
110

Two Bedrooms Three Bedrooms Four Bedrooms

Five Bedrooms

DoC Responsible Party:

Panasonic Corporation of North America
Two Riverfront Plaza, Newark, NJ 07102
1-866-292-7299

Customer Call Support:

Risk of Fire: Type IC-Inherently Protected, Only Use LED Lamp, Max 7W, Type GU24.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation.

DESCRIPTION

These products are listed by UL under UL file No. E78414.
These products use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is
designed to have long operating life, high dynamic response, higher speed ranges with saving energy.
The grille covering the fan body is a spring-loaded, quick remove type. A damper for preventing air counter
flow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level.

FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful interference in a residential installation. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful 
interference to radio communications. However, there is no guarantee that interference will not occur in 
a particular installation. If this equipment does cause harmful interference to radio or television reception, 
which can be determined by turning this product on and off, the user is encouraged to try to correct the 
interference by one of the following measures:

The lighting unit is an energy-saving LED lighting device that uses two 7W LED lamps and produces almost 
the same illumination as a standard 60W incandescent lamp.

Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect equipment into outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.

Warning: This equipment must be installed by qualified person in accordance with the provided installation 
instructions; and all applicable codes and standards. Also, any changes or modifications not expressly 
approved by the party responsible for compliance could void the user’s authority to operate this equipment. 

UNPACKING

Unpack and carefully remove the unit from carton.
Refer to the Supplied Accessories list to verify that all parts are present.

Содержание FV-05-11VKL1

Страница 1: ...11 15VKL1 INSTALLATION INSTRUCTIONS Ventilating Fan Model No Contents FV 05 11VKSL1 FV 05 11VKL1 FV 11 15VKL1 Representative models 2 3 3 4 4 4 5 5 5 6 6 7 7 8 8 10 10 11 11 BACK COVER BACK COVER BACK COVER READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product Please read these instructions carefully before attempting to install operate or service the Panasonic product F...

Страница 2: ...ribe the level of hazard injury and property damage caused when the denotation is disregarded and improper use is performed To reduce the risk of fire electric shock or injury to persons observe the following CAUTION Denotes a potential hazard that could result in serious injury or death Denotes a hazard that could result in minor injury The following symbols are used to classify and describe the ...

Страница 3: ...ith a method which is not approved in the instructions WARNING This product must be properly grounded Do not use this fan with any solid state speed control device Solid state controls may cause harmonic distortion which can cause motor humming noise When this product is no longer being operated please remove the product to prevent the possibility of falling GENERAL SAFETY INFORMATION CONTINUED Pr...

Страница 4: ...egral transformer The motor is designed to have long operating life high dynamic response higher speed ranges with saving energy The grille covering the fan body is a spring loaded quick remove type A damper for preventing air counter flow is provided The blower uses a high capacity sirocco fan developed to reduce the noise level FCC Note This equipment has been tested and found to comply with the...

Страница 5: ...Light Neutral Power supply AC120V 60Hz AC120V 60Hz Power supply Neutral Black Red Red Green Earth ground Green White White 114 C Fuse Thermally protected Hi Low switch When plug in Multi Speed module switch When plug in other Plug N Play modules On Off Non powered control wires 15 9 2 4 8 1 3 5 6 7 10 11 13 12 14 LED lamp Motion sensor location FV MSVK1 not included Multi Speed module FV 05 11VKSL...

Страница 6: ...s the high speed setting Selecting a particular TIME option will cause the fan to run for the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM Multi Speed Air volume CFM 50 110 110 130 150 0 0 0 0 0 0 40 40 40 60 60 60 40 60 60 80 80 80 40 70 80 100 100 100 40 70 80 100 100 110 120 30 30 30 50 50 50 40 50 50 70 70 70 40 70 70 90 90 90 40 70...

Страница 7: ...necessary to connect wall switch when only plug in FV NLVK1 fan can operate on high speed with wall switch control fan can also operate on low speed when used in combination with the FV VS15VK1 INDICATION PLUG N PLAY FUNCTION DEVICES CONTINUED The distance that motion can be detected is limited to 10 feet 3m The field of view of the sensor is 90 Room temperature is 25 C PLUG N PLAY Modular Compone...

Страница 8: ...tor from fan body by removing the machine screw M4X6 before installation Fig 1 IMPORTANT Remove the tape from damper and adaptor before installation As shown below The fan position between joists from 16 to 24 on center can be adjusted flexibly 2 Bend down 4 tabs for positioning install the TM Flex Z Fast bracket to joists by using 2 tapping screws ST4 2X20 Please prepare the screws and TM TM put ...

Страница 9: ... black Light Netural to white Netural to white Junction box Two red wires Connect to a general manual wall switch Earth ground to green INSTALLATION NEW CONSTRUCTION CONTINUED CAUTION CAUTION Machine screw M4X6 2 Self drilling screws Joist Plug connector Receptacle 9 Finish ceiling work Ceiling hole should be aligned with the inside edge of the flange Fig 7 Fig 7 10 1 2 270 1 0 1 2 2 7 0 Ceiling U...

Страница 10: ... fan body to adaptor by using machine screw M4X6 Fig 16 Secure machine screw M4X6 to the suitable TM hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw slip teeth Ceiling Flange Joist Machine screw M4X6 2 Self drilling screws Fix the TM flange and Flex Z Fast bracket through the ceiling 15 Adjust Pick A Flow switch if used adjust the FV VS15VK1 Multi Speed mod...

Страница 11: ...ot immerse motor in water when cleaning Do not soak resin parts in water over 140 F 60 C WARNING CAUTION 4 Install the LED lamps CX GU24 H B 7W as shown in step 1 and step 2 of Fig 9 Page 9 WARNING Remove dust and dirt from light cover and lens before replace the lamps The LED lamps should be replaced as the specified type The supplied LED lamps are not intended for other use CAUTION 3 Replace the...

Страница 12: ...irection Exhaust Exhaust Exhaust 4 or 6 Exhaust Voltage V Voltage V Frequency Hz Frequency Hz Noise sones Noise sones Speed rpm Speed rpm Power W Power W Fan Fan Lighting unit Lighting unit Weight lb Weight lb Duct diameter inches Duct diameter inches Air volume at 0 1 WG CFM Air volume at 0 1 WG CFM Panasonic corporation 2014 FV 05 11VKSL1 FV 05 11VKL1 FV 11 15VKL1 FV 05 11VKSL1 FV 05 11VKL1 Plug...

Отзывы: