
19-2
19.1 I/O Allocation of Sample Programs
In the sample programs, the internal relays are used as the activation request signal for each operation.
If necessary, replace them with the input contacts that switches, etc are connected.
Basic Configuration
The FP
Σ
positioning unit RTEX is installed in the slot 0. Also, the axes 1 and 2 are designated as the
axes used, and the linear interpolation of 2 axes is designated as a sample operation, by the
Configurator PM in advance.
The FP2 positioning unit RTEX is also installed in the slot 0.
Used contacts and data registers
Number
Descriptions
R0
Request servo on
R1
Request servo off
R2
Request home return
R3
Request positioning start
R4
Request forward JOG for axis 1
R5
Request reverse JOG for axis 1
R6
Request forward JOG for axis 2
R7
Request reverse JOG for axis 2
R8
Request pulser operation for axis 1
R9
Request pulser operation for axis 2
R10
Error clear
R11
Request setting value change
R100
Operation enabled flag for axis 1
R101
Off edge of forward JOG for axis 1
R102
Off edge of reverse JOG for axis 1
R103
Off edge of pulser operation for axis 1
R200
Operation enabled flag for axis 2
R201
Off edge of forward JOG for axis 2
R202
Off edge of reverse JOG for axis 2
R203
Off edge of pulser operation for axis 2
Содержание FP2 Positioning Unit RTEX
Страница 1: ......
Страница 6: ...iv ...
Страница 14: ...xii ...
Страница 15: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Страница 21: ...Chapter 2 Parts and Functions ...
Страница 22: ...2 2 2 1 Parts and Functions FPΣ Positioning Unit RTEX FP2 Positioning Unit RTEX ...
Страница 24: ...2 4 ...
Страница 25: ...Chapter 3 Wiring ...
Страница 27: ...3 3 3 2 Network Connector RJ45 plug is connected to the network connector Pins of RJ45 plug Connecting diagram ...
Страница 31: ...Chapter 4 Power On Off and Items to Check ...
Страница 36: ...4 6 ...
Страница 37: ...Chapter 5 4BPreparation For Operation ...
Страница 45: ...Chapter 6 5BI O Allocation ...
Страница 53: ...Chapter 7 6BSetting Tool Configurator PM ...
Страница 83: ...7 31 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Страница 102: ...7 50 ...
Страница 103: ...Chapter 8 7BAutomatic Operation Position Control ...
Страница 118: ...8 16 ...
Страница 119: ...8 17 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Страница 141: ...Chapter 9 8BManual Operation JOG Operation ...
Страница 146: ...9 6 ...
Страница 147: ...Chapter 10 9BManual Operation Home Return ...
Страница 155: ...Chapter 11 10BManual Operation Pulser Operation ...
Страница 159: ...Chapter 12 11BStop Functions ...
Страница 162: ...12 4 ...
Страница 163: ...Chapter 13 12BSupplementary Functions ...
Страница 177: ...13 15 Sample program When reading AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Страница 179: ...13 17 Sample program When writing AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Страница 183: ...Chapter 14 Precautions During Programming ...
Страница 187: ...Chapter 15 Errors and Warnings ...
Страница 212: ...15 26 ...
Страница 213: ...Chapter 16 Troubleshooting ...
Страница 214: ...16 2 16 1 Cannot Communication With AMP ...
Страница 215: ...Chapter 17 Specifications ...
Страница 275: ...Chapter 18 Dimensions ...
Страница 276: ...18 2 18 1 FPSigma Positioning Unit RTEX ...
Страница 277: ...18 3 18 2 FP2 Positioning Unit RTEX ...
Страница 278: ...18 4 ...
Страница 279: ...Chapter 19 Sample Programs ...
Страница 283: ...19 5 ...
Страница 286: ...19 8 ...
Страница 288: ......