4.3 System Register Settings
4.3.1 Confirming and Selecting Functions to be Used
The set condition can be confirmed by the following procedure. The following procedure is
explained on the condition that the FPWIN GR7 has already started.
1.
Select
Options
>
System register settings
from the menu bar.
The "PLC Configuration" dialog box appears.
2.
Select "Controller output setting (PLS / PWM)" from the left pane.
3.
Confirm the functions to be used and change the settings as necessary.
4.
Press the [OK] button.
The screen returns to the ladder edit screen. The settings will be downloaded to the PLC
together with programs.
● When the settings are saved in the Configurator PMX, the system registers corresponding
to the I/O used for the positioning function will be automatically set.
● Change the settings of the corresponding system registers when the home input is not
used or the PWM output is allocated to other channels.
4.3 System Register Settings
WUME-FPXHPOSG-01
4-17