1.3 Comparison of Pulse Output Function
1.3.1 Types of Positioning Control Modes
For using the FP-XH pulse output function, the following two control modes are available.
■
Table setting mode
● Positioning parameters such as position command and speed command are created as data
tables by tool software Configurator PMX in advance.
● As parameters are set in advance, programs can be simplified.
● Four patterns of position control modes and five patterns of home return modes are
available.
● Dedicated instructions F380 to F385 are used for the control.
● Set positioning parameters and information on positioning tables can be exported as a setup
file of Configurator PMX and reused between multiple units and projects.
■
FP-X compatible instruction mode
● Positioning parameters such as position command and speed command are set as operands
of instructions.
● Dedicated instructions F171 to F175 and instructions F0 and F1 are used for the control.
● The system is similar to the pulse output function of the conventional FP-X.
1.3.2 Selection of Positioning Control Mode
● The positioning control mode is selected in the system register no. 407 by the tool software.
(Note 1)
If the compatible mode setting is set to “FP-X mode”, "Table setting mode" cannot be selected.
1.3.3 Comparison of Two Control Modes
There are following differences between the table setting mode and FP-X compatible instruction
mode.
1.3 Comparison of Pulse Output Function
1-8
WUME-FPXHPOSG-01
Содержание FP-XH Series
Страница 2: ... MEMO 2 WUME FPXHPOSG 01 ...
Страница 18: ... MEMO 1 10 WUME FPXHPOSG 01 ...
Страница 30: ... MEMO 3 8 WUME FPXHPOSG 01 ...
Страница 51: ...4 4 Reading Elapsed Values WUME FPXHPOSG 01 4 21 ...
Страница 52: ... MEMO 4 22 WUME FPXHPOSG 01 ...
Страница 88: ... MEMO 5 36 WUME FPXHPOSG 01 ...
Страница 94: ... MEMO 6 6 WUME FPXHPOSG 01 ...
Страница 140: ... MEMO 9 8 WUME FPXHPOSG 01 ...
Страница 193: ... MEMO WUME FPXHPOSG 01 ...
Страница 194: ...Panasonic Industrial Devices SUNX Co Ltd 2020 October 2020 WUME FPXHPOSG 01 ...