Dial-Out Setup for PPP-Client
FP Web-Server V2.11
132
Comments:
•
It is possible to dial up one Internet Service Provider (Dial-up ISP) and use the email
server(s) from a second ISP (email ISP). However, some ISPs will not allow this.
Using one ISP for both dialup and email is recommended.
•
In the Internet, email server(s) are normally addressed with a name rather than with its
direct IP address. But for name resolution, the IP address of an Domain Name Server
(DNS) is necessary. (FP Web-Server hardware version using BIOS v1.03 simplifies
DNS usage).
For easier configuration using the email server(s), direct IP addresses are
recommended (...if they can be acquired and are not changed by the email ISP).
•
An SMTP (Simple Mail Transfer Protocol) server is needed to send emails. An Internet
SMTP server only allows registered users (registered email sender addresses) to send
emails. Additionally some email ISPs protect their SMTP servers with a login procedure.
For this a POP3 email server is used to check the user name and password before an
email can be sent.
Most of the time a POP3 login is used.
•
You can also set up an FP Web-Server that is configured as a PPP-Server which can
the be dialed up by a distant FP Web-Server's PPP-Client (instead of an ISP). This FP
Web-Server, i.e. the PPP-Server, works as a dialup gateway for a LAN where an email
server can be used to send emails.
•
For further details on special connections, please refer to the following:
-
"When Using a Cellular Phone (GSM) Modem (see page 135)"
-
"When Using GPRS Internet Connections (see page 136)"
-
"When Using ISDN Adapters (see page 136)"
10.1.2 Notes for Advanced Users
Idle timeout
If you use the FPWIN Pro library ”M_CE_Lib” to send emails, you have to increase the idle
timeout for Internet dialup operations. In the library delivered (see installation path ”Programs /
Panasonic MEW Control / FP-WEB2 / FPWIN-Pro_Example”) with FP-Web-Tool version 1.3
and later, the idle timeout is already set to 3 minutes.
Gateways
If your FP Web-Server is configured to use a gateway, i.e. if communication with the FP
Web-Server is set up via a gateway, you need to take into account that the FP Web-Server does
not use this gateway during an active dialup connection. This means that TCP port, FPWIN,
Содержание FP Web-Server
Страница 3: ......
Страница 11: ......
Страница 12: ...Chapter 1 Getting Started...
Страница 21: ...Getting Started FP Web Server V2 11 10 1 6 FP Web Server Block Diagram...
Страница 23: ......
Страница 24: ...Chapter 2 Hardware Description...
Страница 41: ......
Страница 42: ...Chapter 3 First Steps...
Страница 55: ......
Страница 56: ...Chapter 4 Configurator Software...
Страница 61: ......
Страница 62: ...Chapter 5 Base Configuration...
Страница 66: ...Chapter 6 Email Setup...
Страница 80: ...Chapter 7 Http Server Functions Web Pages...
Страница 104: ...FP Web Server V2 11 7 1 Details on the FP Web Server s Web Page Functions 93 TEST HTM Displayed in the Browser...
Страница 113: ......
Страница 114: ...Chapter 8 Ethernet RS232C Ports...
Страница 119: ......
Страница 120: ...Chapter 9 Dial In Setup for PPP Server...
Страница 125: ...Dial In Setup for PPP Server FP Web Server V2 11 114...
Страница 127: ...Dial In Setup for PPP Server FP Web Server V2 11 116...
Страница 139: ......
Страница 140: ...Chapter 10 Dial Out Setup for PPP Client...
Страница 150: ...Chapter 11 NTP Server for PLC Clock Synchronization...
Страница 153: ......
Страница 154: ...Chapter 12 Modbus Functions...
Страница 162: ...Chapter 13 IEC 60870 Functions of the FP Web Server...
Страница 168: ...Chapter 14 Java Applet Library MEW JAR...
Страница 170: ...Chapter 15 Additional Information...