background image

INSTRUCTION MANUAL

Simple Wire-saving Unit for Leak Detection Sensor

EX-FC1

MJE-EXFC1 No.0052-90V

Thank you very much for purchasing Panasonic products.

Please read this Instruction Manual carefully and thoroughly for the correct 

and optimum use of this product.

Kindly keep this manual in a convenient place for quick reference.

In case of using sensing devices for prevention of accidents etc. which 

damage a human life or properties, be sure to construct the system so 

that all of the machinery operates to the safety side. This product itself 

does not posses control functions needed for accident prevention or 

safety maintenance.

OUTLINE

1

 

This is the simple wire-saving unit which can be connected with max. 8 

leak detection sensors.

 

Even if only one leak detection sensor is connected to this product, the out-

put is gained when leak is detected or the sensor is mounted improperly.

 

Since the exclusive snap

 

male connector (

SL-CP1

) is used for connec-

tion, wire-saving can be easily made.

MOUNTING

3

 

In case of using screws 

• 

Mount using M4 pan head screws 

with a tightening torque of 0.8N·m 

or less. However, in case of side 

mounting, make sure to mount the 

unit such that the unit stopper faces 

front.

Mounting position 1

 

Two installation positions are available for the unit mounting base so that 

the unit direction can be changed. Install the base at one of them.

Mounting position 2

Unit

Unit mounting base

Din rail stopper

7

6

5

4

3

2

1

0

Unit

Unit mounting base

DIN rail stopper

 

In case of using a DIN rail or the 

mounting bracket (MS-DIN-3) 

(optional).

1. Fit the rear part of the unit mount-

ing base on a 35mm width DIN rail 

or the mounting bracket (

MS-DIN-3

(optional).

2. Press down the front part of the 

unit mounting base on the 35mm 

width DIN rail and fit the front part 

of the base on the DIN rail.

*  For removal, insert a flathead 

screwdriver into the DIN rail stop-

per and pull towards yourself.

1

2

DIN rail stopper

35mm width DIN rail or the mounting 

bracket (

MS-DIN-3

) (Optional)

Flathead screwdriver

DIN rail stopper

Unit stopper

Unit

Unit mounting 

base

M4 pan head screw

Please arrange 

separately.

 

When mounting the unit, be sure to use the unit mounting base

(

MS-SL-2

) (accessory).

 

When installing the unit mounting base to the unit, insert the base 

aligned with the grooves of the unit and move until the unit stopper is 

locked.

Grooves

Unit stopper

1. Insert aligned with the 

groove of the unit.

2. Make the unit stopper 

locked.

I/O CIRCUIT DIAGRAM (for 1 channel)

4

Note: Since the output does not incorporate a short-circuit protection circuit, make sure to use 

this product within the specification and take care against wrong wiring.

12 to 24V DC±10%

Main circuit

Sensor side

Internal circuit

Users’ circuit

IN

*1

No

connection

0V

Terminal No.

(Brown) 12 to 24V DC±10%

(White) OUT

(Black) OUT

Relay contact

(1a contact)

(Blue) 0V

Color code

* 1

Non-voltage contact or NPN open-collector transistor

(amplifier built-in leak detection sensor)

or

PART DESCRIPTION

2

2

1

4

3

5

Designation

Function

1 Normal indicator

(Green × 8)

Lights up when sensors are connected to each channel 

and the connection setting switch is set to ON.

2 Error indicator

(Red × 8)

Lights up when leak is detected by any sensor con-

nected or any sensor is mounted improperly.

For details, refer to “

CONNECTION SETTING 

SWITCH

.”

3 Output indicator

(Orange)

Lights up when the output relay is ON (Normal).

4 Connection setting 

switch

Set the switch to ON when the leak detection sensor is 

connected, set to OFF when the leak detection sensor 

is not connected.

5 Connector

Connect the leak detection sensors.

Отзывы: