background image

853

Related Information

FIBER

SENSORS

LASER

SENSORS

PHOTOELECTRIC

SENSORS

MICRO

PHOTOELECTRIC

SENSORS

AREA

SENSORS

LIGHT

CURTAINS

PRESSURE / 

FLOW

SENSORS

INDUCTIVE

PROXIMITY

SENSORS

PARTICULAR

USE SENSORS

SENSOR

OPTIONS

SIMPLE

WIRE-SAVING

UNITS

WIRE-SAVING 

SYSTEMS

MEASUREMENT

SENSORS

STATIC CONTROL

DEVICES

ENDOSCOPE

LASER

MARKERS

PLC /

TERMINALS

HUMAN MACHINE 

INTERFACES

ENERGY CONSUMPTION 

VISUALIZATION 

COMPONENTS

FA COMPONENTS

MACHINE VISION 

SYSTEMS

UV CURING 

SYSTEMS

Selection 

Guide

Wafer Detection

Liquid Leak 

Detection

Liquid Level 

Detection

Water Detection

Color Mark 

Detection

Hot Melt Glue 

Detection

Ultrasonic

Small /  

Slim Object Detection

Obstacle 

Detection

Other Products

SQ4

EX-F70/

EX-F60

Liquid

Sensor body

Leakage pan

Leakage pan

Leak Detection Sensor 

Amplifier Built-in

EX-F70 

SERIES

  EX-F60 

SERIES

 

General terms and conditions ........... F-17

 

General precautions ..................... P.1405

High-speed detection even a little liquid leak

Reliable detection

The unique effect of 

capillarity enables reliable 

detection of small leaks 

and viscous liquids.

EX-F70 SERIES

No need for sensitivity adjustment

No need for sensitivity adjustment with adjuster, so initial 

mounting is easy.

Easy operation check

Safe design

If the sensor is not mounted correctly, if the cable is 

broken or disconnected, or if the sensor is not operating 

correctly, the output is the same as when the beam is 

not received (LEAK). Design deals with human errors 

such as, forgetting to mount, etc.

This sensor is equipped with a NORMAL indicator (green) 

which lights up when mounting correctly, and a FAULT 

indicator (red) which lights up when sensing the leaked liquid 

or when mounted incorrectly (forgetting to mount exclusive 

mounting bracket). So, the operation can be checked easily.

PVC mounting bracket available

A mounting bracket made of PVC (polyvinyl chloride) is 

available. This mounting bracket can be used normally in 

environments that would corrode normal metal brackets.

Easy installation & reset

Facilitates easy installation: the SUS mounting bracket 

type can be installed using only a single screw and the 

PVC mounting bracket type can be installed using only 

two screws or an adhesive. No component replacement 

required for resetting after leak detection. The simple 

shape makes it easy to wipe off the leaked liquid.

Capillarity effect

New type of detection method

When a leak occurs, the beam from the beam-emitting part scatters 

through the leaked liquid and is not transmitted to the beam-receiving part.

<When leakage occurs>

<When there is no leakage>

Beam-emitting part Beam-receiving part

Leakage pan

Leaked

liquid

Sensing

surface

Beam-emitting part Beam-receiving part

Leakage pan

Sensing

surface

The beam from the beam-emitting part

scatters through the leaked liquid and is

not transmitted to the beam-receiving part.

The beam from the beam-emitting part

reflects off of the surface of the sensor and

is transmitted to the beam-receiving part.

Compact, space-saving

This slim (10 mm 

0.394 in

side-mounting sensor is 

especially good for use  

in confined spaces.

SUS mounting bracket type 

EX-F71

□ 

 

PVC mounting bracket type 

EX-F72

□ 

 

10 mm 

0.394 in 

approx. 

EX-F72

Conforming to

EMC Directive

Recognition

 

Sensor selection guide ................. P.831~

 

Korea’s S-mark ............................. P.1410

Certified

(Excluding PNP output type)

panasonic-electric-works.net/sunx

Содержание EX-F60 SERIES

Страница 1: ...tly and a FAULT indicator red which lights up when sensing the leaked liquid or when mounted incorrectly forgetting to mount exclusive mounting bracket So the operation can be checked easily PVC mounting bracket available A mounting bracket made of PVC polyvinyl chloride is available This mounting bracket can be used normally in environments that would corrode normal metal brackets Easy installati...

Страница 2: ...5 m 16 404 ft cable length type of EX F71 PN is EX F71 PN C5 Simple wire saving unit for leak detection sensor Appearance Model No Output EX FC1 Relay contact 1 a 5 m 16 404 ft cable length type PFA enclosure gives excellent chemical resistance The sensor enclosure and the cable sheath are made from PFA which is highly resistant to chemicals Accurate sensing is achieved even if there are leaks of ...

Страница 3: ...0 V or less at 50 mA source current 0 4 V or less at 16 mA source current Utilization category DC 12 or DC 13 Output operation In normal state ON When leak detected or the sensor is mounted improperly OFF Short circuit protection Incorporated Response time 50 ms or less FAULT indicator Red LED lights up when the leak liquid is detected or the sensor is mounted improperly NORMAL indicator Green LED...

Страница 4: ...Mechanical lifetime 50 million switching operations or more switching frequency 180 operations min Utilization category DC 12 or DC 13 Output operation The output relay is ON when the input signal from the sensor is ON Note 2 Response time 5 ms or less excluding the response time of the sensor Input No 8 Nos Indicators Normal Green LED 8 light up when the sensor is connected to each channel and th...

Страница 5: ...nsistor Users circuit Internal circuit 50 mA max Blue 0 V Brown V Black Output Color code 12 to 24 V DC 10 Tr D ZD Load Sensor circuit Blue Brown Black 12 to 24 V DC 10 Load Blue Brown Black 12 to 24 V DC 10 Load EX F7 PN EX F6 PN PNP output type I O circuit diagram Wiring diagram EX F7 PN EX F6 PN I O circuit diagram for one channel Note The output does not incorporate a short circuit protection ...

Страница 6: ... thick the sensor body cannot be fitted to the mounting bracket How to fit the sensor body to the exclusive mounting bracket Match the notch in the sensor body with the projection of the exclusive mounting bracket and slide till a click is felt When mounting make sure to use the brackets included with the unit in order to eliminate human error such as forgetting to install If the included brackets...

Страница 7: ... to each channel and the connection setting switch is set to ON Error indicator Red LED 8 Lights up when leak is detected by any sensor connected or any sensor is mounted improperly For details refer to Connection setting switch Output indicator Orange LED Lights up when the output relay is ON Normal Connection setting switch Set the switch to ON when the leak detection sensor is connected set to ...

Страница 8: ...ake sure that the power supply is off while wiring Verify that the supply voltage variation is within the rating Take care that if a voltage exceeding the rated range or an AC power supply is directly applied the sensor may get damaged or burnt If power is supplied from a commercial switching regulator ensure that the frame ground F G terminal of the power supply is connected to an actual ground I...

Страница 9: ...ing bracket for EX F72 PN MS EX F7 3 For two point fixing MS EX F7 2 For adhesive fixing Note A M4 stud bolt has been welded to this unit M4 nut is not supplied with the sensor Purchase it separately Note M4 stud bolts have been welded to this unit M4 nuts are not supplied with the sensor Purchase it separately 26 5 1 043 16 0 630 35 9 1 413 28 5 1 122 10 7 0 421 ø2 5 ø0 098 cable 2 m 6 562 ft lon...

Страница 10: ...1 024 ø2 5 ø0 098 cable 3 m 9 843 ft long NORMAL indicator Green FAULT indicator Red 19 0 748 9 0 354 3 0 188 14 0 551 19 0 748 FAULT indicator Red NORMAL indicator Green 2 ø4 2 ø0 165 4 5 0 177 17 0 669 MS EX F6 1 PFA mounting bracket Stainless steel bush 18 0 709 27 1 063 26 1 024 Adhering surface 21 5 0 846 26 1 024 27 1 063 MS EX F6 2 PVC mounting bracket 3 0 188 14 0 551 19 0 748 FAULT indica...

Отзывы: