92
Installation Manual
SOLAR DC INPUT
Maximum Power
3250 W per MPPT channel / 6500 W total
Operation / MPPT Voltage Range
120 to 500VDC / 250 to 430VDC
Minimum Start Voltage
150VDC
Maximum Input Current
13A / 13A (two string input)
AC OUTPUT TO LOAD
Output Power (Continuous) @ 25°C
5500W
Overload 40/5/1sec @ 25°C
5500/6500/7500W
Rated Output Current
23 A ( @120V and 240 V)
Output Frequency (Selectable)
50/60Hz
Output Voltage
L-N: 120V ± 3%; L-L: 240V ± 3%
Total harmonic distortion (THD) at rated power
< 5%
Power Factor
>99%
AC INPUT FROM GRID (GRID SUPPORT)
AC Input Voltage Limits (Bypass)
L-L: 180 to 280V (240 V nominal)
Automatic Transfer Relay Rating / Typical Transfer Time
48A / 20ms
AC Input Frequency Range (Bypass)
55 to 65 Hz
AC OUTPUT TO GRID
Output Power (Continuous) @ 25°C
5000W
Grid Sell Current Range ( Depending On Operation Mode)
0 to 24A (@Low Grid, 211V)
Grid Sell Voltage Range
L-L: 211 to 264V ± 3.0V
Grid Sell Frequency Range
59.4 to 60.4Hz ± 0.05Hz
EFFICIENCY
Peak PV to Grid
96%
CEC weighted PV to Grid
95.5%
21. SPECIFICATIONS
Specifications
DC-Coupled System