background image

3

INPUT AND OUTPUT CIRCUIT DIAGRAM

4

MOUNTING

Be sure to turn off the power before carrying out angle adjustment for this

product, otherwise accidents or problems with operation may occur.

 

٨

If installing this product directly to the enclosure, use M3 screws. (M3 screws 

should be arranged separately.)

 

٨

If using the 

ER-QMS1

 (optional mounting bracket), use the screws provided with 

the mounting bracket.

 

٨

If using SUNX mounting bracket or screws other than the 

ER-QMS1

, do not use 

screws which are longer than 10 mm, otherwise they may cause damage to 

internal parts when fastened.

 

٨

Tightening torques are 0.5 N

m for M3 screws and 1.2 N

m or less for M4 screws.

 

٨

If using several of these products alongside each other, leave a space of 50 mm 

or more between each product, otherwise product performance may be adversely 

affected.

[If installing this product directly to the enclosure]

[If using the 

ER-QMS1

 (optional mounting bracket)]

5

OPTIONS

6

CARE AND MAINTENANCE

Be sure to turn off the power before carrying out cleaning and maintenance.

The discharge needle has a sharp point, so be very careful when cleaning the

needle.

 

After long periods of use, dirt may adhere to the discharge needles, the area

around them and the filter. If these areas are not cleaned, charge removal

performance will drop and accidents or problems with operation may occur.

Therefore they should be periodically cleaned (discharge needles: about once

���������������������������������������

INSTRUCTION MANUAL

Static Remover  Ultra-compact Fan Ionizer

ER-Q

CMJE-ERQ No.0031-24V

Thank you very much for using Panasonic products. Please read this 

Instruction Manual carefully and thoroughly for the correct and optimum use 

of this product. Kindly keep this manual in a convenient place for quick 

reference.

WARNING

 

٨

Never use this product with a device for personnel protection.

In case of using devices for personnel protection, use products which meet laws 

or standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable 

in each region or country.

 

٨

�����������������������������������������������������������������������������

combustible items being present.

 

٨

��������������������������������������������������������������������������������

about once a month), otherwise optimum charge removal performance may not be 

�������������������������������������������������

 

٨

If this product is used in an airtight room, ozone emitted from this product may be 

detrimental. Therefore, in order for this product to be used in an airtight room, be 

sure to keep the room ventilated.

 

٨

Do not direct ionized air toward the face. Ozone may cause irritation to places 

such as the nose and throat. 

 

٨

������������������������������������������������������������������������������������

discharge needle, or injuries may result.

 

٨

Be sure to ground the frame ground (F.G.) terminal, otherwise electric charge 

removal may not be reliable.

 

٨

Take care not to let any foreign objects get into the fan air inlet, otherwise 

accidents or operating problems may occur.

1

OUTLINE

 

٨

This is a static charge remover which utilizes ion generation by means of corona 

discharge.

 

٨

It has a compact shape, so that it can be positioned either vertically or horizontally.

 

٨

It is equipped with an automatic stop function which operates when the discharge 

needle unit has been removed.

2

PART DESCRIPTION

Ion air outlet

Discharge needle unit

58

65

52

60

3.5

29
33

3.5

Filter cover

Alarm indicator

(red)

2-�3.5 mm

mounting hole

Discharge indicator

(green)

Power switch

Fan speed control

 (Note 1)

�3.7 mm cable

Connector 5559-08P

manufactured by MOLEX

2-M3 screws (depth 10 mm)  (Note 2)

25.4

19.8

5.5

Notes: 1)  Fan speed control 

This is set to MAX fan speed at the time of shipment from the factory. 

Use a precision screwdriver (-) to adjust the fan speed.

2)  Screw threads exclusive for SUNX mounting brackets.  Do not use them in mounting with

other products. 

�����������������������������������������������������������������������������������������

mounting holes.

 

٨

 Description of indicators 

Discharge indicator (DSC) ...  Lights during discharge  

(when ions are being generated)

Alarm indicator (ALARM) ...    Lights when discharge error or discharge checking 

occurs, blinks when fan error occurs.

9

SPECIFICATIONS

Item

Type

Fan type ionizer

Model No.

ER-Q

Charge removal time

1.5 sec. approx. (Note 1)

Ion balance

±10 V or less (Note 1)

Power supply voltage

24 V DC ±10 %

Power consumption

200 mA or less

Discharge method

High-frequency AC method

Discharge output voltage

±2 kV approx.

Max. fan speed

6.4 m/s (Note 1)

Max. fan volume

0.2 m

3

/min

Output

(CHECK, ALARM)

NPN transistor/open collector

��������������������������

��Applied voltage: 30 V DC or less (between output terminal and 0 V)

�����������������������������������������������������������

Output operation

Check:  On when discharge check (Note 2) detected 

Off at all other times

Error:  Off when discharge error or fan error (Note 2) detected 

On at all other times

Short-circuit protection

Incorporated

Indicators

DSC

Green LED (Lights up during normal discharge)

ALARM

Red LED (Lights up during discharge checking and when 

discharge error (Note 1) detected, blinks when fan error (Note 1) 

detected)

Ozone generation amount

0.02 ppm or less (Note 1)

Ambient temperature

0 to + 50°C (No dew condensation) / Storage temperature: -10 to + 65°C

Ambient humidity

35 to 65% RH (No dew condensation) / Storage temperature: 35 to 65% RH

Vibration resistance

10 to 150 Hz frequency, 0.75 mm amplitude in X, Y and Z 

directions for two hours each

Material

Enclosure: PBT   Discharge needle: Tungsten

Grounding method

C (capacitor) grounding

Weight

110g approx. (main unit only)

Accessories

٨

Wiring connector: 1 set 

[Manufactured by MOLEX: Housing (5557-08P), Terminal (5556T)]

Notes: 1)  Representative value at 100 mm from directly in front of fan outlet, maximum fan speed 

�������������������������

2)  Discharge check: Drop in discharging status detected. 

Discharge error: Abnormal discharge detected. 

Fan error: Fan operating problem detected.

10

CAUTIONS

٨

This product has been developed / produced for industrial use only.

٨

Do not use this product for any purpose other than charge removal and dust removal.

٨

���������������������������������������������������������������������������������

otherwise operating problems or damage may occur. In addition, the operating life 

�����������������������������������������������

٨

Never disassemble, repair or modify this product, otherwise operating problems or 

accidents may occur.

٨

Do not dispose of this product by burning it, otherwise it may explode or toxic

fumes may be generated.

٨

This product generates ozone, so be sure to provide adequate ventilation if using 

����������������������

٨

Do not run the wires together with high-voltage lines or power lines or put them in 

the same raceway. This can cause malfunction due to induction.

٨

Be sure to turn off the air and the power supply before carrying out any cable

connection or inspection work. If this is not done, operating problems, damage or 

electric shocks may occur.

٨

After connecting the cables, check that the connections are correct before turning 

on the power. If the cables are connected incorrectly, operating problems or

accidents may occur.

٨

Verify that the supply voltage variation is within the rating.

٨

It takes approximately 2 seconds after the power is turned on before the fan

operation stabilizes. To ensure proper charge removal performance, do not use

���������������������������������������������

٨

Do not turn the power back on immediately after it has been turned off, otherwise 

operating problems or accidents may occur. In addition, the operating life of the 

��������������������������������������������������������������������������������

the power back on again.

٨

Do not use any cables which have any damage (such as splitting or cracking),

otherwise operating problems or accidents may occur.

٨

Avoid using the product in places where there are high levels of steam or dust in 

the air or where it might be directly exposed to water, oil or welding spatter.

٨

Do not touch the discharge needle with hard objects such as tools. If the discharge 

���������������������������������������������������������������������������������

and moreover operating problems or accidents may occur.

٨

������������������������������������������������������������������������������������

with operation may occur.

٨

��������������������������������������������������

٨

����������������������������������������������������������������

٨

Secure the main unit properly when setting up. If the main unit is not correctly

secured or if it is subjected to intermittent vibrations or impacts, accidents or

problems with operation may occur.

٨

����������������������������������������������������������������������������������

fan air intake, otherwise accidents or problems with operation may occur.

٨

Use  cables  with  a  cross-section  of  0.15  mm

2

or  more  and  a  length  of  less  than

30 m. Furthermore, keep the cables as short as possible to avoid the possibility of interference.

٨

If this product ceases functioning or is no longer required, dispose of it according 

to appropriate local waste disposal regulations.

M3 screw
Spring washer

Flat washer

The discharge needles are consumable parts. If the discharging performance is

not restored after the discharge needles have been cleaned, it is recommended

that you replace the whole discharge needle unit (option). It is recommended that

you replace the discharge needle unit after about 10,000 hours of operation.

[Cleaning and replacement procedure for discharge needle unit]

Ԙ

Follow the procedure given below to remove the discharge needle unit from the main unit.

ԙ

Use a cotton swab or similar moistened in alcohol to clean the discharge needles 

and the areas around them.

If the needles are particularly dirty, use a brush (such as a toothbrush) moistened 

with alcohol to rub them clean, and then use a cotton swab to wipe them.

A commercially-available ultrasonic cleaner can also be used for cleaning. (Immerse

the discharge needle unit into the cleaning tank to clean them.)

Ԛ

Insert the tabs of the discharge needle unit into the two slots in the main unit, slide 

the discharge needle unit sideways to install it to the main unit until a click is heard.

[Discharge needle unit removal procedure]

*  Do not touch the interior of the main unit when removing and installing the discharge 

needle unit, otherwise accidents or problems with operation may occur.

*  Do not apply any more force than is necessary when removing and installing the

discharge needle unit, otherwise the discharge needle unit may become damaged.

����������������������������������������������

���������������������������������������������������������������

7

OPERATION MATRIX

Indicator 

(O: Lit, 

٨

: Off,  : Blinking)

Output

Discharge 

operation

Fan 

operation

Discharge 

(DSC)

Alarm 

(ALARM)

Check

Error

Green

Red

Normal open Normal closed

Normal

٤

٨

OFF

ON

ON

ON

Discharge check

٤

٤

ON

ON

ON

ON

Discharge error

٨

٤

OFF

OFF

OFF

OFF

Fan error

٨

OFF

OFF

OFF

OFF

*  Once an error has been detected, the error status will be maintained until the power

is turned off and back on again.

* Eliminate the cause of the error before turning the power back on again.

* If the cause of the error has not been eliminated, the error will occur again.

8

TROUBLESHOOTING

Be sure to turn off the power before checking the discharge unit or the fan unit.

Problem

Probable cause

Remedy

Discharge check

Discharge 

٤

Alarm        

٤

Dirty discharge 

needle

Wear

Condensation

F.G. not 

connected

Check that the power supply voltage is within the usable 

range.

Turn off the power and check that the tips of the discharge 

needles are not worn or dirty and that the discharge 

needle unit is correctly installed to the main unit.

If the alarm indicator remains lit even after the discharge 

needles have been cleaned, check for any dirt around 

the discharge needles also.

Check that the F.G. terminal is securely connected to the round.

Discharge error

Discharge 

٨

Alarm        

٤

Foreign object 

obstruction

Condensation

F.G. not 

connected

Check that the power supply voltage is within the usable 

range.

There may be an abnormal discharge. Turn off the 

power and check that the discharge needles are not 

dirty or broken and that the discharge needle unit is 

correctly installed to the main unit.

If the alarm indicator remains lit even after the discharge 

needles have been cleaned, check for any dirt and 

foreign objects around the discharge needles also.

Check that the F.G. terminal is securely connected to the ground.

Fan error

Discharge 

٨

Alarm     

Fan intake 

covered

Filter blocked

Foreign object 

obstruction

������������������������������������������������������

Check if there are any foreign objects inside the product.

* Indicators (

٤

: Lit, 

٨

: Off, 

: Blinking)

* The M3 and M4 screws are included with the 

ER-QMS1

.

Ԙ

 Install bracket 1 to the main unit with the M3 screws.

ԙ

 Install bracket 2 to the main unit with the M4 sems screws, and then use the M4 screw 

mounting holes to install to the enclosure.

Ԙ

ԙ

2-M3 screw 

(depth 10 mm)

M3 sems screw

Bracket 1

M4 screw 

mounting hole

M4 sems screw

Bracket 2 

g

 AC adapter

Model No.

Details

Model No.

Details

Model No.

Details

Model No.

Details

Model No.

Details

g

 Replacement discharge needle unit

Unit with tungsten needles

g

 Replacement air filter

5-piece air filter set

g

 Cable with connectors

Cable length 2 m
Cable length 5 m

g

 Mounting bracket

Mounting bracket for air 

direction adjustment

IN: 100 to 240 V AC, 50/60 Hz, 40 VA

OUT: 24 V DC, 750 mA

ER-VAPS1

ER-QANT

ER-QFX5

ER-QCC2

ER-QCC5

ER-QMS1

  1   

Hook your finger into the slot in the 

discharge needle unit and slide the 

unit in the direction shown in the 

illustration until a click is heard.

  2   

After this, you can pull the 

discharge needle unit toward you 

to remove it.

1

2

24 V DC

±10 

Ċ

30 V

DC MAX

D

1

Tr

1

ZD

1

D

2

Load

COM (+)

50 mA MAX

(Black) Error output

Tr

2

ZD

2

D

3

Load

COM(-)

50 mA MAX

(Orange) Check output

(Green) F.G.









(Brown) +24 V

(Blue) 0 V

Internal circuits

User’s circuits

Main circuit

D

1

: Power supply reverse connection 

protection diode

D

2

, D

3

: Output protection diodes

ZD

1

, ZD

2

: Surge voltage absorption Zener diodes

Tr

1

, Tr

2

: NPN output transistors

Connector pin layout diagram

Terminal no. Terminal name

Lead wire color

0 V

COM (-)

N.C. (Not used)

F.G.

24 V

COM(+)

Check output 

Error output

Blue

Green

Brown

Orange

Black

Front view

Ԙ

Turn the filter cover in the direction shown in the illustration to align the * marks.

ԙ

Remove the filter cover and the filter from the 

ER-Q

 main unit.

Ԛ

Remove the filter from the filter cover, and remove any dust and dirt adhering to the filter. If the 

filter is extremely dirty, wash it in water. If washing the filter in water, let it dry thoroughly before 

using it again.

ԛ

Install the filter and the filter cover to the 

ER-Q

 main unit.

* If the filter is used while it is still wet, accidents or problems with operation may occur. 

* If the filter cannot be cleaned, replace it.

* Be careful not to let any foreign objects get inside the main unit when removing and installing the 

filter.

ޓԘ

ԙ

http://panasonic.net/id/pidsx/global

PRINTED IN JAPAN

© Panasonic Industrial Devices SUNX Co., Ltd. 2012

Overseas Sales Division (Head Office)

2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 

Phone: +81-568-33-7861  FAX: +81-568-33-8591

About our sale network, please visit our website.

Ramco National

800-280-6933 | [email protected]

www.panasonicsensors.com

Отзывы: