background image

Fire alarm system 

EBL512

 

________________________________________________________________________ 

Panasonic Electric Works 

2008-08-20                          Fire & Security Technology Europe AB                         Page 1 of 6 

 

 
 

Fire alarm system EBL512 

 

 
 
 

An analog addressable fire alarm system 

for early detection without unwanted alarms 

 

 

 

 

www.panasonic-fire-security.com

Содержание EBL512

Страница 1: ..._____________________________________ Panasonic Electric Works 2008 08 20 Fire Security Technology Europe AB Page 1 of 6 Fire alarm system EBL512 An analog addressable fire alarm system for early detection without unwanted alarms www panasonic fire security com ...

Страница 2: ... Power Supply The c i e can on four COM loops handle up to 512 input and or output units i e detectors manual call points general in and output units for free programmable user definable functions etc Each loop unit uses one address Conventional detectors can also be used in the system Control and Indication Equipment EBL512 EBL512 can work as a standalone unit or in a TLON network with up to 30 u...

Страница 3: ...a certain level A large number of alarm algorithms is supported by the system and can be set for each analog detector individually Alert annunciation The output for the alarm transmitter can be delayed for immediate on site investigation of a fire alarm Individual detectors zones programmable outputs and outputs for the alarm transmitter can be individually disabled Internally and or externally co...

Страница 4: ...e data can also be uploaded from the c i e Win512 is also used to download new software etc System overview C i e 1548 1826 Ext FBP 1828 Ext FBP 1735 36 AA unit 1728 EPU 4301 Analog photoelectric smoke detector 3333 3339 Addr Manual Call Point TLON Network 1590 board 1590 board 1590 board 1580 board 0 7 1587 board COM loop External PC system Web browser LAN or Internet 4300 Analog multi detector 3...

Страница 5: ...ctors Fast connectors Ext LED output 4300 Analog multi detector 4301 Analog photoelectric smoke detector 4313 Analog base with isolator For analog detectors Detector to be plugged in Analog base 3312 or 4313 Conventional Detectors connected to a COM loop via a zone line input e g 3361 2324 Base For conventional detectors 4318 Combination heat detector 59 degrees rate of rise 4350 Multi detector 43...

Страница 6: ..._____________________________________________ Panasonic Electric Works Fire Security Technology Europe AB Citadellsvägen 23 SE 211 18 Malmö Sweden Tel 46 0 40 697 70 00 Fax 46 0 40 697 70 99 info fste eu pewg panasonic com www panasonic fire security com ...

Отзывы: