manualshive.com logo in svg
background image

Installation Instructions

Infrared Receiver for Y

Model No. 

CZ-RWRY3

Safety Precautions ...................................... 2
Installation Precautions .............................. 3
Supplied accessories .................................. 4
Part Names ................................................... 4
Wiring ........................................................... 5
Mounting ...................................................... 6
Setting .......................................................... 7

Address Setting ................................................ 7

Test Operation ............................................. 8

Self-diagnostics table and detected contents .......... 9

Specifi cations ............................................ 10

Contents

English

Read through the Installation Instructions before you proceed 

with the installation.

In particular, you will need to read under the “Safety 

Precautions” on page 2.

WEB-ACXF60-40460-EN

W0921-0

Содержание CZ-RWRY3

Страница 1: ...rt Names 4 Wiring 5 Mounting 6 Setting 7 Address Setting 7 Test Operation 8 Self diagnostics table and detected contents 9 Specifications 10 Contents English Read through the Installation Instructions before you proceed with the installation In particular you will need to read under the Safety Precautions on page 2 WEB ACXF60 40460 EN W0921 0 ...

Страница 2: ...locating or repairing this receiver provide the Installation Instructions to the servicing personnel Do not clean inside the receiver by users Engage authorised dealer or specialist for cleaning WARNING CAUTION This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death This symbol refers to a hazard or unsafe practice which can result in personal injury o...

Страница 3: ... weak infrared light for its signal which can result in the signal not being received because of the following influences so take care in where the indoor unit is installed Inverter or rapid start type fluorescent lights Models without glow lamps Plasma display or LCD televisions Direct sunlight or other sources of bright light Do not bundle together with the power source wiring or store in the same...

Страница 4: ...cessories Number of pieces Installation Instructions 1 Part Names 1 Light receiving section Receives signals 3 Indication lamp Indicates operation status 2 Emergency operation button Starts Stops emergency operation ...

Страница 5: ...d remote controller to Main and set the infrared receiver to Sub Installation example R1 R2 1 2 CN001 R1 R2 R1 R2 R1 R2 1 2 CN001 Indoor unit Indoor unit Indoor unit Indoor unit Terminals for RC wiring RC wiring No polarity Receiver Sub Wired RC Main Receiver Sub Wired RC Main Using 1 indoor unit Using more than 1 indoor unit Note The receiver can be connected to any indoor unit for operation Mult...

Страница 6: ...right of the ceiling panel and remove the corner cover Indentations Ceiling panel Corner cover Corner cover 4 Hang the string of the receiver on the pin of the ceiling panel Receiver Pin String Ceiling panel 5 Fit the receiver to the ceiling panel so the 5 claws are properly set and fix it with the removed screw Make sure the wire is not caught Refer to the installation instructions supplied with t...

Страница 7: ...Setting When more than 1 receiver is installed in the same room setting addresses prevents interference For how to change addresses of infrared remote controllers see the operating instructions of infrared remote controllers Settings are all off at the time of shipping Infrared remote controller address display Address Address Address Address Address Address Address ON OFF States ALL 1 2 3 4 5 6 In...

Страница 8: ...TIMER STANDBY blink during test operation 3 To finish test operation press and hold the emergency operation button for 10 seconds or more Attention Do not use this mode for purposes other than the test operation To prevent overload of the units Read the installation instructions supplied with the units The test operation can be performed in Heat or Cool mode Temperature cannot be changed The test o...

Страница 9: ...ly Operation of outdoor protection device P02 P08 P15 P31 Alternately Error in the indoor thermistor F01 F03 F10 F11 Alternately Error in the outdoor thermistor F04 F09 F12 F28 Alternately Error in the indoor EEPROM F29 Simultaneously Error in the outdoor EEPROM F30 F31 Simultaneously Error related to the compressor H01 H31 Error in indoor settings L01 L03 L05 L09 Simultaneously Error in outdoor s...

Страница 10: ... electrical and electronic products must not be mixed with general household waste For proper treatment recovery and recycling of old products please take them to applicable collection points in accordance with your national legislation By disposing of them correctly you will help to save valuable resources and prevent any potential negative effects on human health and the environment For more info...

Страница 11: ...Panasonic Corporation http www panasonic com Panasonic Corporation 2021 WEB ACXF60 40460 EN W0921 0 ...