Panasonic CZ-CAPE2 Скачать руководство пользователя страница 1

POWER

CN309

OP1

3P (Yellow)

DC12V

EP valve

Balance valve

Intake valve

Output valve

5P (Black)

Indoor control PCB

Signal output cables

(short)

(Supplied part 

)

CN81

3WAY

Optional parts

Solenoid valve 

kit or gas pipe 

valve kit

CN002

POWER

3P (White)

[AC Power Input]

CN001

OPTION/3WAY

6P (White)

CN003

9P (Red)

[Solenoid valve output]

Protective ground screw

Protective ground screw

Protective ground screw

Solenoid valve control PCB

Optional board box

Indoor unit

Power cables (2 core)(Supplied part

)

Models where installation is possible in indoor unit electrical box

POWER

CN309

OP1

3P (Yellow)

DC12V

EP valve

Balance valve

Intake valve

Output valve

5P (Black)

Indoor control PCB

Signal output cables

(long)

(Supplied part 

)

CN81

3WAY

Optional parts

Solenoid valve 

kit or gas pipe 

valve kit

CN002

POWER

3P (White)

[AC Power Input]

CN001

OPTION/3WAY

6P (White)

CN003

9P (Red)

[Solenoid valve output]

Protective ground screw

Protective ground screw

Protective ground screw

Solenoid valve control PCB

Optional board box

Indoor unit

Power cables (3 core)(Supplied part

)

Normal installation

Solenoid Valve

Installation (Electric) and Service Instructions

1. Safety Precautions

3. Wiring Diagram

The connected solenoid valve is a solenoid valve kit, or a gas pipe valve kit.

Controller(CZ-CAPE2)

Optional board box

screws 4x10 (2 locations)

OPTION/3WAY

(CN001)

6P White

POWER

(CN002)

3P White

6P White

screw 4x4

5P Black

CN003

9P Red

Spacers (4 locations)

Optional parts

9P Red

Solenoid valve

kit or gas pipe

valve kit

Protective ground screw 

for

power cable (3 core)

Protective ground screw 

for solenoid valve kit or gas pipe valve kit

4. Installation Procedures

Note: See the reverse side for procedures for installation on various indoor units.

Models where installation is possible in indoor unit electrical box

1. Install the spacers for the solenoid valve control PCB in the electrical box.

2. Wire according to the following procedure.

3. When you have finished wiring work, check to be sure that there are no nipped portions in the wiring.

Connect the 3P white connector of  power cable(2 core) (Supplied part 

) to POWER (CN002) on 

the solenoid valve control PCB.
Connect the 3P yellow connector to OP1 (CN309) on the indoor control PCB.
Connect the 6P white connector of Signal output cable (the short cable) (Supplied part 

) to OPTION/3WAY (CN001) on

the solenoid valve control PCB.
Connect the 5P black connector to 3WAY (CN81) on the indoor control PCB. 
Connect the connector from the solenoid valve kit or gas pipe valve kit (9P red) to the 9P red connector (CN003) on the solenoid valve 
 control PCB.

Connect the ground wire of the solenoid valve kit or gas pipe valve kit to the indoor unit 
using the screw and washer (supplied part 

).

* For the connecting location, refer to the indoor unit installation instructions. 

Power cable (2 core) (Supplied part 

)

3P Yellow

To indoor control PCB

OP1(CN309)

3P White

Signal output cable (short cable) (Supplied part 

)

5P Black

To indoor control PCB

3WAY (CN81)

6P White

CN003

9P Red

OPTION/3WAY

(CN001)

6P White

POWER

(CN002)

3P White

Optional parts

Solenoid valve 

kit or gas pipe 

valve kit

9P Red

① 

Solenoid Valve Control PCB

 Nylon clamp(F7,F14)

3P Yellow

3P White

 Signal output cables(long/short)

5P Black

6P White

② 

Power cables (3 core/2 core) 

3P Yellow

3P White

⑤ 

Fastening screws

Screw 4x4-2 

(1 pc.)

Screw 4x10-2  (2 pcs.)

④ 

Optional board box

⑦ 

Protective ground screw

for indoor unit

Screw 4x8-3

Washer

Cable tie (4 pcs.)

Connect to the indoor control PCB with

 

power cable(2 core/3 core) (Supplied part

) and Signal output cable (Supplied part

)

Signal output cable (long/short) (Supplied part 

)

3P Yellow

3P White

Power cable (3 core/2 core) (Supplied part 

)

The following is intended for the person responsible for installing or servicing the Solenoid Valve

Controller. Before conducting installation or electrical work, be sure to carefully read these

“Safety Precautions”. Follow instructions exactly in all installation or electrical work.

The precautions given in this manual consist of specific “Warnings” and “Cautions”. They provide

important safety related information and are important for your safety, the safety of others, and

troublefree operation of the system. Be sure to strictly observe all safety procedures. The labels and

their meanings are as described below.

This symbol refers to a hazard or unsafe procedure or practice which can result in

severe personal injury or death.

Warning

Caution

This symbol refers to a hazard or unsafe procedure or practice which can result in

personal injury or product or property damage.

Warning

Be sure to arrange installation at the dealer where the system was purchased or use a professional

installer.

Leaks, electric shock or fire may result if an inexperienced person performs any installation or wiring

Be sure to turn off the power source circuit breaker of the unit before installation or wiring.

High electrical voltages used in the unit may cause electric shock.

procedures incorrectly.

Only a qualified electrician should attempt to install this system, in accordance with the provisions of

the Technical standards for Electrical Installations, local regulations for indoor wirings and these

“Installation (Electric) and Service Instructions”. Be sure to use a dedicated electrical circuit.

Insufficient electrical circuit capacity may cause electric shock or fire.

Use the specified cables (type and wiring diameter) for the electrical connections, and securely connect

the cables. Run and fasten the cables securely so that external forces or pressure placed on the cables

will not be transmitted to the connection terminals. Overheating or fire may result if connections or

attachments are not secure.

Install in a location that is fully strong enough to support the weight of the unit. If it is not strong enough,

the unit may fall, resulting in injury.

Ventilate the work area if cooling gas leaks during installation. Poisonous gas can result if cooling gas

comes into contact with fire.

After installation, check to be sure that there are no gas leaks.

Poisonous gas can result if cooling gas leaks into the room and comes into contact with a fan heater,

stove, range, or other source of fire.

Caution

Do not install in a location subject to leakage of flammable gasses.

Fire can result if gas builds up around the unit.

2. Supplied Parts

1. Install the solenoid valve control PCB in the optional board box with the following procedure.

2. Wire according to the following procedure.

3. When you have finished wiring work, secure the cover of the optional board box with the supplied screw (4x4)

Install the board spacers in the holes in the base of the optional board box.
Note: When you do so, be careful of the direction of the solenoid valve conrol PCB(see following figure).
Attach the optional board box to the unit with the supplied screws(4x10).

Models without space inside electrical box 

Connect the 3P yellow connector of power cable (Supplied part 

)  to OP1 (CN309) on the indoor control PCB.

Connect the 5P black connector  of signal output cable (Supplied part 

) to 3WAY (CN81) on the indoor control PCB.

Connect the ground wire of the power cables (3 core) to the indoor unit using the screw and washer (supplied part 

).

* For the connecting location, refer to the indoor unit installation instructions.

*

When you use the power cables (2 core) for installing inside electrical box, ground connection is unnecessary.

 

Connect the ground wires of the power cables and solenoid valve kit or gas pipe valve kit to the optional board box.

*

When you use the power cables (2 core), only connect the ground wire of the solenoid valve kit or gas pipe valve kit

.

Connect the 3P white connector of power cable(Supplied part 

) to POWER(CN002) on the

solenoid valve control PCB.
Connect the 6P white connector of signal output cable(Supplied part 

) to OPTION/3WAY(CN001) on the

solenoid valve control PCB.
Connect the connector from the solenoid valve kit or gas pipe valve kit (9P red) to the 9P red connector (CN003) on the
solenoid valve control PCB.
Fasten the wires to the optional board box with the cable ties (supplied part 

)

Note: When you do so, check to be sure that there are no nipped portions in the wiring.

Use the long cables and 3 core cables 
when the solenoid valve controller is 
installed outside the indoor unit.

Printed in Japan     85464369377012

To indoor control PCB

OP1(CN309)

To indoor control PCB

3WAY (CN81)