Thank you for
buying Panasonic
Air Conditioner
ACXF55-31900
When installing, use the nearest power outlet. Make sure the power outlet is easy to
reach so you can quickly disconnect your air conditioner in case of emergency.
Ensure that the air conditioner is well supported, securely fastened, easily reachable
and not obstructed.
Aviod location with: salty or sulphurous air, draughts, dampness and flammable gas.
If you install the drainage system, be sure to channel the concensed water to a
suitable location.
Covers, obstructions and unsteady support may cause excessive operating noise and vibration.
The rear end of the air conditioner is splash proof. You don’t need to shield or cover it.
R32 refrigerant air conditioner installation and maintenance should be done by competent person.
Always use at the rated voltage and with a specific air conditioning circuit.
This equipment must be earthed and strongly recommended to be installed with Earth Leakage Circuit Breaker
(ELCB) or Residual Current Device (RCD). Otherwise, it may cause electric shock or fire in case of malfunction.
Time delay fuse or circuit breaker rating is 16 Ampere for CW-XN1821EA
;
20 Ampere for CW-XN2421EA
.
Nominal cross sectional area of power supply wire must be 3 core x 2.5 mm
2
or above.
The power supply must be from an independent circuit.
All electrical installations must be made in accordance with local wiring and safety regulation wherever applicable.
There must be a double pole switch with a minimum of 3.5 mm contact gap in the fixed installation circuit.
Please engage and authorized dealer or specialist for the installation work.
Do not use the unit for other purposes, than its intended use.
Do not remove the power plug by pulling the cord.
Do not block the air intake and outlet vanes.
Do not splash or direct water at the unit.
Do not expose the unit to direct sunlight during operation.
Do not operate the unit without the air filter installed
or when the front intake grille has been removed.
Do not place any objects on the unit.
Do not operate any combustion equipment near the unit’s
air flow area.
Do not sit or step on the unit, you may fall down accidentally.
Do not touch the sharp aluminium fin, sharp parts may
cause injury.
Do not use means to accelerate the defrosting process or to
clean, other than those recommended by manufacturer.
Plug in properly before operating and use a specified power cord.
If abnormal conditions (burnt smell, etc.) occur, switch off and
remove the power plug.
Confirm to authorized dealer or specialist on usage of specified
refrigerant type. Using of refrigerant other than the specified
may cause product damage, burst and injury etc.
This appliance is not Intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given super-
vision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
Switch off the breaker and unplug the unit from the socket
if the unit will not be operated for a long period.
Pay attention to any damages on the unit caused by
extensive usage.
Ventilate the room occasionally where the unit is installed.
Unplug the power cord when cleaning the unit.
NOTES:
If operation is stopped, and to be restarted immediately, the unit will resume operation only after 3 minutes.
Open the cover.
Insert the two batteries.
Close the cover.
Do not use rechargeable (Ni-Cd) batteries
because such batteries differ from the
standard dry cell batteries in shape,
dimensions and performance.
Remote Control
Be sure to observe the following:
Aim remote control at control panel
on air conditioner when operating.
Do not drop or throw the remote control.
Do not place the remote control in a
location that is exposed to direct
sunlight or next to a heating unit or
other heat Sources.
Touch Control Panel
OPERATION PRECAUTION
MAIN UNIT
ACCESSORIES
HOW TO INSERT BATTERIES
This sign warns of risk of
death or serious injury.
This sign warns of risk of injury
or damage to property.
Do not modify the length of power cord or use an extension cord.
Do not touch or operate with wet hands.
Do not modify or damage the cord.
Do not turn on the unit by inserting the power plug.
Do not switch off the unit by pulling out the power plug.
Avoid an extended period of direct airflow.
Do not Insert your fingers or other objects into the unit, rotating
parts may cause injury.
Do not try to repair the unit yourself.
PARTS IDENTIFICATION
2
PREPARATION BEFORE OPERATING
3
CHOOSING THE INSTALLATION LOCATION
PREPARATIONS BEFORE INSTALLATION
CAUTION POINT DURING INSTALLATION
INSTALLATION PROCEDURES
REMOVAL OF FRONT GRILLE
ELECTRIC WORK
CONDENSED WATER DRAINAGE
AIR CONDITIONER INSTALLATION
4
When installing air conditioner at glass window or thin partition,
fix the vertical and side supporting bar to the concrete wall in order to
support the weight of the air-conditioner and reduce the vibration that
is being transferred to the glass window or thin partition.
This can minimize the noise problem caused by improper installation.
Proposed to use 1/8” x 1-1/4” “angle-aluminium for
installation frame and side supporting bar.
This air conditioner employs a “Slinger-Up System” which is designed to splash the condensed water on the condenser coil
for maximum cooling efficiency, thus producing a splashing sound. If the splashing sound annoys you, you can provide an
outside drainage by using the following the procedure which may, cause a small loss of performance.
NOTE: If the unit is installed at a coastal area, drainage of condensed water is recommended to prevent easy condenser corrosion.
NOTE:
OPERATING INSTRUCTIONS
ROOM AIR CONDITIONER
ENGLISH
CW-XN1821EA
CW-XN2421EA
Vertical airflow direction vane
(Airflow direction adjustment up-down).
The vertical airflow direction vane is
controlled by positioning the vent to
discharge the air upwards, downwards,
or straight out.
Air Inlet Louver
Front Grille
Cabinet
Air Filter
(behind the front intake grille)
Touch Control Panel
Front Intake Grille
Remove the rubber plug and chassis locking
bracket from the cabinet. Then slides the chassis
out from the cabinet.
1
Connect a drain hose. Fit the drain hose to the drain pan.
Underside view with drain
pan and hole in place.
3
Slide the chassis back into the cabinet. Lock the chassis to
the cabinet reusing the chassis locking bracket.
Then reinstall the cabinet to the chassis.
4
Install the drain pan
Install the drain pan at the
right corner of the cabinet
using 2 screws.
Screws
Drain pan
2
Drain hose or tubing can be purchased
locally to satisfy your particular needs.
Clockwise
Counter
Clockwise
Chassis locking
bracket
Remove the
rubber plug
INTERNAL VIEW
Over100cm
80cm
This symbol shows that this equipment uses a flammable refrigerant.
If the refrigerant is leaked, together with an external ignition source,there is a possibility of ignition.
This symbol shows that the Operating Instructions should be read carefully.
This symbol shows that service personnel should be handling this equipment with reference to the
Technical Manual.
This symbol shows that there is information included in the Operating Instructions and/or
Installation Instructions.
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
The appliance shall be stored in a room without continuously operating ignition sources
(for example: open flames, an operating gas appliance or an operating electric heater)
Do not install, remove and reinstall the unit yourself.
Improper installation may cause Leakage, electric shock or fire. Please engage an authorized dealer
or specialist for the installation work.
Do not add or replace refrigerant other than the specified type.
It may cause product damage, burst and injury. If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similar qualified persons in order to avoid hazard.
The room air conditioner must be earthed.
Improper grounding could cause electric shock.
Do not install the unit in a place where there are explosive gas leaks.
Gas leaks near the unit could cause fire.
Ensure that the drainage piping is connected properly.
R32
Otherwise water will leak out.
In cases that require mechanical ventilation, ventilation openings shall be kept clear of obstruction.
Ventilate any enclosed areas when installing or testing the refrigeration system.
Escaped refrigerant gas, on contact with fire or heat, can produce dangerously toxic gas.
Confirm after installation that no refrigerant gas is leaking. If the gas comes in contact with a burning
stove, gas water heater, electric room heater or other heat source, it can cause the generation of toxic gas.
INSTALLATION PRECAUTION
SAFETY PRECAUTIONS
1
Please observe these following safety precautions when using your air conditioner.
Failure or negligence in observing these safety precautions could cause fire, electrical shock or personal injury.
This sign warns of risk of
death or serious injury.
This symbol (with a white background) denotes an action that is
PROHIBITED.
These symbols (with a green background) denote actions
that are COMPULSORY.
Risk of fire /
Flammable
materials
This sign warns of risk of
injury or damage to property.
FANSPE
ED
POW ERFU
L
SLEEP
FAN SP
EED
AIR
SWING
AUTO
AIR SW
ING
TEMP
SLEEP
FAN SPEED
AIR
SWING
AUTO
AIR SWING
TEMP
Signal Transmitter
TEMPERATURE
Setting Button
FAN SPEED Selection Button
POWERFUL Button
TIMER SET
ON TIMER button
OFF TIMER button
TIMER SET button
TIMER CANCEL SET button
Display panel
ON/OFF Button
MODE Selection Button
SLEEP Button
AIR SWING Button
SLEEP
FAN SPEED
AIR
SWING
AUTO
AIR SWING
TEMP
The batteries can be used for approximately one year.
Be sure to replace the batteries with two new identical batteries.
Remove the batteries if the air conditioner will not be used for an extended period of time.
ABOUT THE BATTERIES
OPERATION CONDITIONS
Use the air conditioner
under the following
conditions:
Operating temperature range.
Continuous operation at over 90% high humidity
may create condensation and result in
waterdrops on the intake and outlet vanes.
Max. Temperature
Min. Temperature
NOTE:
Humidity may exceed 90%
32
Indoor side
23
16
11
D.B.T.: Dry Bulb Temperature
(unit in °C)
D.B.T.
W.B.T.
W.B.T.: Wet Bulb Temperature
43
Outdoor side
26
16
11
D.B.T.
W.B.T.
■
Avoid installation in the following locations.
●
Mechanical processing plants and other places with a lot of mechanical oil.
●
High humidity areas such as laundry room and bathroom.
■
Air conditioner normal operating temperature.
●
In side maximum temperature 30
℃
●
Out side maximum temperature 43
℃
■
NOTICE:
When the air conditioner is used at room temperature of 21 degrees or less,
the temperature may be too low, and the air conditioner may be easily
frosted. After frosting, it may be difficult to drain and may flow into the room.
There should not be any obstacles surrounding the unit.
Prepare and installation hole slightly bigger than the cabinet size.
Left and right side of the unit should be at least 15 cm
away from the wall.
The minimum installation height is 75cm.
(Based on IEC 60335-2-40, there is no restriction for the minimum installation
floor area since the refrigerant charges is less than 1.224kg.
Dimension
Remove the chassis locking
bracket from the cabinet. Save for later use.
1
Slide the chassis out from the cabinet
2
Place the cabinet into the installation hole.
3
Slide the chassis into the cabinet.
4
Counter clockwise
Chassis locking bracket.
Lock the chassis to the cabinet reusing the
chassis locking bracket.
5
Depending upon the location of AC outlet,
route the AC cord to either left or right side
before Installing the front grille.
6
This figure shows the AC cord routed to the left side.
Attach the front grille to the cabinet
and fasten it with a screw.
7
Attach air filter to the front
grille. (see anti-bacterial
filter installation
instructions included
in this package)
8
Position the intake grille horizontally and hook the front grille fulcrum
to the grille force arm.
9
10
Front Grille Fulcrum
Body Support
Grille Force arm
Insert front grille tabs
into the cabinet slots
Open the Intake Griille until over 90°
front grille fulcrum can remove from Grille force arm.
1
Remove the front grille.
Remove the screw on the front grille.
At the bottom right side of the front grille,
press inward on the cabinet near the power
cord, and pull the grille outward to the right
until right tab releases.
At the bottom left side, push inward on the
cabinet and pull the grille outward to the left
to release the left tab. Do not pull the bottom
edge towards to you for more than 3 inches to
prevent the two top tabs from damage.
Slide the front grille upwards to loosen the two
top tabs from slots at the top of the cabinet.
3
a
b
c
d
Remove the air filter.
Tilt up and pull out the air filter by the holder.
2
air filter
Front Grille Fulcrum
Body Support
Grille Force arm
TYPES OF SIGNAL SOUND - One long “BEEP”
and one short “BEEP” . (Sound from the main unit.)
TIMER SET
SLEEP
POWERFUL MODE
ON/OFF
TEMP
AIR SWING
FILTER CLEAN
●When the filter cleaning light flashes or brighten,it is recommended to
clean the filter after dismantle.Filter cleaning light will flashes about 20
second,if didn’t press the “FILTER CLEAN“, it will keep brighten
after flashes about 20 second.
●After the filter is cleaned, touch theFILTER CLEAN button on the control
panel,and the unit will beep once (the model filter cleaning light goes out).
●When the machine has been running for 500 hours, the filter cleaning
light will flash for about 20 seconds and then go out after the machine
is turned on and off. If it is not reset, restart the timer. After the machine
is turned on for 800 hours, the filter cleaning light will flash for about 20
seconds and then stay on. .
Ventilation Lever
The ventilation lever must be
in CLOSE position in order to
maintain the best cooling
conditions.When fresh air is
necessary in the room, set
the ventilation lever to the
Open position. The damper
is opened and room air is
drawn out.(If the ventilation
lever is OPEN, there is a
chance that noisy noise can
be introduced into the room)
indoor
outdoor
Outdoor
Press down control panel and close the cover.
Remote control
Two R03 dry-cell batteries
Drain pan