Operating Instructions
Air Conditioner

Before operating the unit, please read these operating 
instructions thoroughly and keep them for future reference.
Before installation, the installer should:
Read the Installation Instructions, then request the customer 
keep them for future reference.
Remove the remote control packed with the indoor unit.
* Kindly consult authorised dealer for connectivity validity.

ACXF55-31460

Operating Instructions

Air Conditioner

Model No.
Indoor Unit

Outdoor Unit

Single Split

CS-RZ60XKRW
CS-RZ71XKRW
CS-RZ80XKR

CU-RZ60XKR
CU-RZ71XKR
CU-RZ80XKR

* Outdoor Unit
Multi Split

CU-4Z71VBR
CU-4Z80VBR
CU-5Z100VBR

Содержание CS-RZ60XKRW

Страница 1: ...llation Instructions then request the customer keep them for future reference Remove the remote control packed with the indoor unit Kindly consult authorised dealer for connectivity validity ACXF55 31460 Operating Instructions Air Conditioner Model No Indoor Unit Outdoor Unit Single Split CS RZ60XKRW CS RZ71XKRW CS RZ80XKR CU RZ60XKR CU RZ71XKR CU RZ80XKR Outdoor Unit Multi Split CU 4Z71VBR CU 4Z8...

Страница 2: ... indoor unit Quick Guide Inserting the batteries 1 2 3 1 Pull out the back cover of remote control 2 Insert AAA or R03 batteries 3 Close the cover A Clock setting 1 Press then press to set the time Press for approximately 5 seconds to show the time as 12 hour am pm or 24 hour 2 Press SET to confirm AIR CONDITIONER ON OFF SET TIMER CANCEL OFF ON TEMP OFF ON MODE POWERFUL ECO SLEEP FAN SPEED QUIET A...

Страница 3: ... approximately 10 seconds to show the temperature as C or F Thank you for purchasing Panasonic Air Conditioner Table of Contents Safety Precautions 4 11 How to Use 12 13 To Learn More 14 15 Cleaning the Air Conditioner 16 Troubleshooting 17 19 Information Back Cover Accessories Remote control AAA or R03 batteries 2 Remote control holder Screws for remote control holder 2 The illustrations in this ...

Страница 4: ...e supervised to ensure that they do not play with the appliance Please consult an authorised dealer or specialist to clean the internal parts repair install remove disassemble and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than th...

Страница 5: ... if the unit is not going to be used for a long period of time New batteries of the same type must be inserted following the polarity stated Power supply Do not disconnect the plug by pulling the cord to prevent electric shock Power supply Do not use a modified cord joint cord extension cord or unspecified cord to prevent overheating and fire To prevent overheating fire or electric shock Do not sh...

Страница 6: ...al the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use of flammable refrigerants and as recommended by the manufacturer Any personnel conducting an operation servicing or maintenance on a system or associated parts of the equipment should be trained and ce...

Страница 7: ...llow to the precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised and maintained by a trained and certified service personnel who is employed by the person user or party responsible Ensure the actual refrigerant charge is in accordance with the room size wit...

Страница 8: ...ternally into the atmosphere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks shall be applied to installations u...

Страница 9: ...erant in the atmosphere from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans 6 Detection of flammable refrigerants Under no circumstances shall potential sources of i...

Страница 10: ... minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position according to the instructions Ensure that the refrigerating system is earthed prior to charging the system with refrigerant Label the system when charging is complete if not already Extreme care shall be taken not to over fill the refrigerating system Prior to recharging the system it shall be ...

Страница 11: ...ders are employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order Recovery cylinders are...

Страница 12: ...is automatically stop after 20 minutes ECO To reduce power consumption for better energy saving without sacrificing comfort To switch between POWERFUL ECO POWERFUL ECO exit setting Indicators POWER TIMER ECO AIR CONDITIONER ON OFF SET TIMER CANCEL OFF ON TEMP OFF ON MODE FAN SPEED QUIET POWERFUL ECO SLEEP AIR SWING Not used in normal operation Press to restore the remote control to default setting...

Страница 13: ...O SLEEP FAN SPEED QUIET POWERFUL ECO Can be selected at the same time Can be activated in all modes POWERFUL QUIET and FAN SPEED cannot be selected at the same time To set the timer ON OFF SET TIMER CANCEL CANCEL 1 2 3 1 Select TIMER ON or TIMER OFF Example OFF at 22 00 Each time pressed OFF exit setting 2 Set the time 3 Confirm the setting SET To cancel the timer press ON or OFF to select the res...

Страница 14: ...cted the indoor unit stops and the POWER indicator blinks COOL Provides efficient comfort cooling to suit your needs DRY Operates at low fan speed for a gentle cooling operation FAN To circulate air in the room Energy saving temperature setting You may save energy when operating the unit within the recommended temperature range HEAT 20 0 C 24 0 C 68 F 75 F COOL 26 0 C 28 0 C 79 F 82 F Air flow dir...

Страница 15: ...door unit 1 Multi split outdoor unit 2 DBT WBT DBT WBT DBT WBT COOL Max 32 89 6 23 73 4 46 114 8 26 78 8 46 114 8 26 78 8 Min 16 60 8 11 51 8 10 14 0 10 14 0 HEAT Max 30 86 0 24 75 2 18 64 4 24 75 2 18 64 4 Min 16 60 8 15 5 0 15 5 0 16 3 2 DBT Dry bulb temperature WBT Wet bulb temperature 1 CU RZ60XKR CU RZ71XKR CU RZ80XKR 2 CU 4Z71VBR CU 4Z80VBR CU 5Z100VBR ...

Страница 16: ...t Insert into the unit Anti bacterial filter Anti bacterial filter Fitting location may vary on models Clean the filter whenever necessary Wash rinse the filter gently with water to avoid damage to the filter Dry the filter thoroughly under the shade away from fire or direct sunlight Replace the filter every 10 years or replace any damaged filter Part no CZ SA22P Indoor unit Wipe the unit gently w...

Страница 17: ...ng odour Airflow continues even after operation has stopped To extract the remaining heat from the indoor unit maximum 30 seconds The room has a peculiar odour This may be due to damp smell emitted by the wall carpet furniture or clothing Cracking sound during operation Changes in temperature caused the unit to expand and contract Water flowing sound during operation Refrigerant flow inside the un...

Страница 18: ...L or HEAT mode For details refer The remote control is missing or a malfunction has occurred above After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4 F HEAT 14 C 25 2 F The units will be not used for an extended period Activate HEAT mode for 2 3 hours to remove any moisture left in the internal parts thorough...

Страница 19: ...tdoor heat sink temperature sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdoor mismatch brand code H 39 Abnormal indoor operating unit or standby units Diagnostic display Abnormality Protection control H 41 Abnormal wiring or piping connection H 50 ...

Страница 20: ...o symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved WARNING This symbol shows that this equipment uses a flammable refrigerant If the refrigerant is leaked together with an external ignition source there is a possibility of ignition This symbol shows that the Operation Instruc...