Air Conditioner

Indoor Unit

Outdoor Unit

CS-RE18JKX-1 CU-RE18JKX-1

CS-RE24JKX-1 CU-RE24JKX-1

TABLE OF CONTENTS

PAGE

PAGE

1 Safety Precautions

-----------------------------------------------

3

2 Specifications

-----------------------------------------------------

5

3 Features

-------------------------------------------------------------

8

4 Location of Controls and Components

-------------------

9

4.1. Indoor Unit--------------------------------------------------- 9
4.2. Outdoor Unit ------------------------------------------------ 9
4.3. Remote Control -------------------------------------------- 9

5 Dimensions

-------------------------------------------------------

10

5.1. Indoor Unit & Remote Control ------------------------ 10
5.2. Outdoor Unit----------------------------------------------- 11

6 Refrigeration Cycle Diagram

--------------------------------

13

7 Block Diagram

---------------------------------------------------

14

8 Wiring Connection Diagram

---------------------------------

15

8.1. Indoor Unit ------------------------------------------------- 15

Содержание CS-RE18JKX-1

Страница 1: ...RE18JKX 1 CS RE24JKX 1 CU RE24JKX 1 TABLE OF CONTENTS PAGE PAGE 1 Safety Precautions 3 2 Specifications 5 3 Features 8 4 Location of Controls and Components 9 4 1 Indoor Unit 9 4 2 Outdoor Unit 9 4 3 Remote Control 9 5 Dimensions 10 5 1 Indoor Unit Remote Control 10 5 2 Outdoor Unit 11 6 Refrigeration Cycle Diagram 13 7 Block Diagram 14 8 Wiring Connection Diagram 15 8 1 Indoor Unit 15 ...

Страница 2: ...n Control For Heating Operation 41 14 Servicing Mode 42 14 1 Auto OFF ON Button 42 14 2 Remote Control Button 43 15 Troubleshooting Guide 44 15 1 Refrigeration Cycle System 44 15 2 Relationship Between The Condition Of The Air Conditioner And Pressure And Electric Current 45 15 3 Breakdown Self Diagnosis Function 46 15 4 Error Codes Table 47 15 5 Self diagnosis Method 48 16 Disassembly and Assembl...

Страница 3: ...electrical work it will cause electrical shock or fire 9 This equipment is strongly recommended to install with Earth Leakage Circuit Breaker ELCB or Residual Current Device RCD Otherwise it may cause electrical shock and fire in case equipment breakdown or insulation breakdown 10 Do not use joint cable for indoor outdoor connection cable Use the specified indoor outdoor connection cable refer to ...

Страница 4: ...eakage 4 Do not touch outdoor unit air inlet and aluminium fin It may cause injury 5 Select an installation location which is easy for maintenance 6 Pb free solder has a higher melting point than standard solder typically the melting point is 50 F 70 F 30 C 40 C higher Please use a high temperature solder iron In case of the soldering iron with temperature control please set it to 700 20 F 370 10 ...

Страница 5: ...510 Running Current A 7 0 12 1 Input Power W 245 1 54k 2 60k 360 2 66k 3 20k COP W W 3 67 3 77 3 08 2 50 3 23 3 09 Kcal hW 3 14 3 24 2 65 2 14 2 78 2 66 Power Factor 96 96 Indoor Noise H L QLo dB A 44 37 47 38 Power Level dB 60 63 Outdoor Noise H L dB A 47 52 Power Level dB 61 66 Low Temp Capacity kW I Power W COP 5 80 2 35k 2 47 7 17 2 83k 2 53 Extr Low Temp Capacity kW I Power W COP 4 98 2 41k 2...

Страница 6: ...50 29 17 32 290 11 7 16 795 31 5 16 Width I D O D mm inch 1070 42 5 32 875 34 15 32 1070 42 5 32 875 34 15 32 Depth I D O D mm inch 235 9 9 32 345 13 19 32 235 9 9 32 320 12 5 8 Weight Net I D O D kg lb 12 26 48 106 12 26 65 143 P I P I N G Pipe Diameter Liquid Gas mm inch 6 35 1 4 12 70 1 2 6 35 1 4 15 88 5 8 Standard Length m ft 5 0 16 4 5 0 16 4 Length Range min max m ft 3 9 8 20 65 6 3 9 8 30 ...

Страница 7: ...ture of 20 C outdoor 2 1 C 4 Heating extreme low temperature capacity Input Power and COP measured at 230 V indoor temperature of 20 C outdoor 7 8 C 5 Specifications are subjected to change without prior notice for further improvement Thermostat Electronic Control Electronic Control Protection Device Electronic Control Electronic Control Dry Bulb Wet Bulb Dry Bulb Wet Bulb Indoor Operation Range C...

Страница 8: ...Piping CS CU RE18JK 1 long piping up to 20 meter CS CU RE24JKX 1 long piping up to 30 meter Easy to use remote control Quality Improvement Random auto restart after power failure for safety restart operation Gas leakage protection Prevent compressor reverse cycle Inner protector to protect compressor Noise prevention during soft dry operation Serviceability Improvement Breakdown Self Diagnosis fun...

Страница 9: ...9 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...

Страница 10: ...10 5 Dimensions 5 1 Indoor Unit Remote Control ...

Страница 11: ...11 5 2 Outdoor Unit 5 2 1 CU RE18JKX 1 ...

Страница 12: ...12 5 2 2 CU RE24JKX 1 ...

Страница 13: ...13 6 Refrigeration Cycle Diagram ...

Страница 14: ...14 7 Block Diagram ...

Страница 15: ...15 8 Wiring Connection Diagram 8 1 Indoor Unit ...

Страница 16: ...16 8 2 Outdoor Unit 8 2 1 CU RE18JKX 1 ...

Страница 17: ...17 8 2 2 CU RE24JKX 1 ...

Страница 18: ...18 9 Electronic Circuit Diagram 9 1 Indoor Unit ...

Страница 19: ...19 9 2 Outdoor Unit 9 2 1 CU RE18JKX 1 ...

Страница 20: ...20 9 2 2 CU RE24JKX 1 ...

Страница 21: ...21 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...

Страница 22: ...22 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Printed Circuit Board ...

Страница 23: ...23 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board 10 2 1 1 CU RE18JKX 1 ...

Страница 24: ...24 10 2 2 Main Printed Circuit Board 10 2 2 1 CU RE24JKX 1 ...

Страница 25: ...25 10 2 3 Power Printed Circuit Board 10 2 3 1 CU RE24JKX 1 ...

Страница 26: ...irect sunlight or rain be careful that heat radiation from the condenser is not obstructed There should not be any animal or plant which could be affected by hot air discharged Keep the spaces indicated by arrows from wall ceiling fence or other obstacles Do not place any obstacles which may cause a short circuit of the discharged air If piping length is over the piping length for additional gas a...

Страница 27: ...of the extended line is the center of the hole Another method is by putting measuring tape at position as shown in the diagram above The hole center is obtained by measuring the distance namely 128 mm for left and right hole respectively Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor side 11 2 2 To Drill a Hole in the Wall and Install ...

Страница 28: ...28 1 For the right rear piping 2 For the right and right bottom piping 3 For the embedded piping ...

Страница 29: ... outdoor unit shall be approved polychloroprene sheathed 4 1 5 mm2 flexible cord type designation 245 IEC 57 or heavier cord Secure the connecting cable onto the control board with the holder clamper This equipment must be properly earthed Ensure the colour of wires of outdoor unit and the terminal Nos are the same to the indoor s respectively Earth wire shall be Yellow Green Y G in colour and lon...

Страница 30: ... cutter and then remove the burrs 2 Remove the burrs by using reamer If burrs is not removed gas leakage may be caused Turn the piping end down to avoid the metal powder entering the pipe 3 Please make flare after inserting the flare nut onto the copper pipes ...

Страница 31: ...r inserting the flare nut located at valve onto the copper pipe Align center of piping to valves and then tighten with torque wrench to the specified torque as stated in the table 11 3 3 Evacuation of the Equipment WHEN INSTALLING AN AIR CONDITIONER BE SURE TO EVACUATE THE AIR INSIDE THE INDOOR UNIT AND PIPES in the following procedure 1 Connect a charging hose with a push pin to the Low side of a...

Страница 32: ...ype designation 245 IEC 57 or heavier cord 4 Connect the power supply cord and connecting cable between indoor unit and outdoor unit according to the diagram below 5 Secure the power supply cord and connecting cable onto the control board with the holder 6 Attach the control board cover back to the original position with screw 7 For wire stripping and connection requirement refer to instruction of...

Страница 33: ... are depending on the air conditioner settings and the operation environment The final shifted value will be used as internal setting temperature and it is updated continuously whenever the electrical power is supplied to the unit 12 1 2 Cooling Operation 12 1 2 1 Thermostat control Compressor is OFF when Intake Air Temperature Internal Setting Temperate 1 5 C Compressor is ON after waiting for 3 ...

Страница 34: ...sed by 3 C and T3 will decreased up to 8 C The Auto Operation Mode shifting will take place whenever operation mode changed from Cooling Soft Dry to Heating or vice versa 12 1 6 Indoor Fan Motor Operation A Basic Rotation Speed rpm i Manual Fan Speed Cooling Dry Fan motor s number of rotation is determined according to remote control setting Heating Fan motor s number of rotation is determined acc...

Страница 35: ...tarts operation and it stops 30 seconds after compressor stops operation 12 2 Airflow Direction 1 There are two types of airflow vertical airflow directed by horizontal vane and horizontal airflow directed by vertical vanes 2 Control of airflow direction can be automatic angles of direction is determined by operation mode heat exchanger temperature and intake air temperature and manual angles of d...

Страница 36: ...conditioner is stopped using remote control the vane will shift to close position 12 2 2 Horizontal Airflow 1 Automatic horizontal airflow direction can be set using remote control the vane swings left and right within the angles as stated below For heating mode operation the angle of the vane depends on the indoor heat exchanger temperature as Figure 1 below 2 Manual horizontal airflow direction ...

Страница 37: ...dge the operation starting time From the above judgment the decided operation will start operate earlier than the set time as shown below 12 4 OFF Timer Control OFF timer can be set using remote control the unit with timer set will stop operate at set time 12 5 Auto Restart Control 1 When the power supply is cut off during the operation of air conditioner the compressor will re operate within thre...

Страница 38: ...ling operation A will be applied 13 1 4 IPM Power transistor Prevention Control A Overheating Prevention Control 1 When the IPM temperature rises to 110 C compressor operation will stop immediately 2 Compressor operation restarts after three minutes the temperature decreases to 95 C 3 If this condition repeats continuously 4 times within 20 minutes timer LED will be blinking F96 is indicated B DC ...

Страница 39: ...mes within 20 minutes the unit will Stop operation Timer LED blinks and F91 indicated 13 1 7 Compressor Tank Temperature Rise Protection Control a Control start conditions For 5 minutes the compressor continuously operates and outdoor total current is between 0 65A and 1 65A During Cooling and Soft Dry operations Indoor suction temperature indoor piping temperature is below 4 C Indoor temperature ...

Страница 40: ...mperature and Indoor pipe temperature judgment by microcontroller if fulfilled When Cooling or Dry mode is operated more than 20 minutes or more 3 This control stopped if Compressor stopped Remote control setting changed fan speed temperature Outdoor air temperature and indoor intake temperature changed 4 Fan speed angle of louver vertical airflow angle will be adjusted accordingly in this control...

Страница 41: ... in 60 minutes 2 Control contents Operation stops Timer LED blinks and H99 indicated 13 3 Protection Control For Heating Operation 13 3 1 Intake Air Temperature Control Compressor will operate at maximum frequency if below conditions occur 1 When the indoor intake air temperature is 30 C or above 13 3 2 Outdoor Air Temperature Control The maximum current value is regulated when the outdoor air tem...

Страница 42: ...ontrol to set change the advance setting of air conditioner operation 3 REMOTE CONTROL NUMBER SWITCH MODE The Remote Control Number Switch Mode will be activated if the Auto OFF ON button is pressed continuously for more than 11 seconds 3 beep sounds will occur at 11th seconds to identify the Remote Control Number Switch Mode is in standby condition and press AC RESET button and then press any but...

Страница 43: ...conds by using pointer Press TIMER SET button until a beep sound is heard as confirmation of transmission code change To change the air quality sensor sensitivity Press and release by using pointer Press the Timer Decrement button to select sensitivity 1 Low Sensitivity 2 Standard Default 3 Hi Sensitivity Confirm setting by pressing Timer Set button a Beep sound will be heard LCD returns to origin...

Страница 44: ... problems before inspecting the refrigeration cycle Such problems include insufficient insulation problem with the power source malfunction of a compressor and a fan The normal outlet air temperature and pressure of the refrigeration cycle depends on various conditions the standard values for them are shown in the table on the right ...

Страница 45: ...es after an operation is started Cooling Mode Heating Mode Condition of the air conditoner Low Pressure High Pressure Electric current during operation Low Pressure High Pressure Electric current during operation Insufficient refrigerant gas leakage Clogged capillary tube or Strainer Short circuit in the indoor unit Heat radiation deficiency of the outdoor unit Inefficient compression ...

Страница 46: ... on 2 Press the CHECK button on the remote controller continuously for 5 seconds 3 will be displayed on the remote controller display Note Display only for No transmitting signal no receiving sound and no Power LED blinking 4 Press the TIMER or button on the remote controller The code H00 no abnormality will be displayed and signal will be transmitted to the main unit The power LED lights up If no...

Страница 47: ...utdoor air temperature sensor abnormality Continue for 5 sec O Outdoor temperature sensor defective or disconnected H28 Outdoor heat exchanger temperature sensor abnormality Continue for 5 sec O Outdoor heat exchanger temperature sensor defective or disconnected H30 Discharge temperature sensor abnormality Continue for 5 sec Discharge temperature sensor H33 Indoor Outdoor wrong connection Indoor O...

Страница 48: ...transmission is checked whether it is normal Malfunction Caused Faulty indoor unit PCB Faulty outdoor unit PCB Indoor unit outdoor unit signal transmission error due to wrong wiring Indoor unit outdoor unit signal transmission error due to breaking of wire in the connection wires between the indoor and outdoor units Indoor unit outdoor unit signal transmission error due to disturbed power supply w...

Страница 49: ...are interconnected Malfunction Caused Wrong models interconnected Wrong indoor unit or outdoor unit PCBs mounted Indoor unit or outdoor unit PCBs defective Indoor outdoor unit signal transmission error due to wrong wiring Indoor outdoor unit signal transmission error due to breaking of wire 3 in the connection wires between the indoor and outdoor units Troubleshooting ...

Страница 50: ...ction Decision Conditions During startup and operation of cooling and heating the temperatures detected by the indoor intake air temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 51: ...n Decision Conditions During startup and operation of cooling and heating the temperatures detected by the outdoor compressor temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 52: ...ions A current transformer CT is detected by checking the compressor running frequency rated frequency and CT detected input current less than 0 65A for continuously 20 seconds Malfunction Caused CT defective Outdoor PCB defective Compressor defective low compression Troubleshooting ...

Страница 53: ...etermine abnormal fan motor feedback of rotation 2550rpm or 50rpm Malfunction Caused Operation stops due to short circuit inside the fan motor winding Operation stops due to breaking of wire inside the fan motor Operation stops due to breaking of fan motor lead wires Operation stops due to Hall IC malfunction Operation error due to faulty indoor unit PCB Troubleshooting ...

Страница 54: ... Decision Conditions During startup and operation of cooling and heating the temperatures detected by the indoor heat exchanger temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 55: ...ction Decision Conditions During startup and operation of cooling and heating the temperatures detected by the outdoor air temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 56: ...ction Decision Conditions During startup and operation of cooling and heating the temperatures detected by the outdoor pipe temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 57: ...tion Decision Conditions During startup and operation of cooling and heating the temperatures detected by the outdoor discharge pipe temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 58: ...alfunction Decision Conditions The supply power is detected for its requirement by the indoor outdoor transmission Malfunction Caused Wrong models interconnected Wrong indoor unit and outdoor unit PCBs used Indoor unit or outdoor unit PCB defective Troubleshooting ...

Страница 59: ...lity Malfunction Decision Conditions If Patrol sensor feedback is 0V or 5V continuous for 6 hours Error will display only when the Patrol operation is ON Malfunction Caused Faulty connector connection Faulty Patrol sensor Troubleshooting ...

Страница 60: ...eration is used to determine abnormal fan motor Malfunction Caused Operation stops due to short circuit inside the fan motor winding Operation stops due to breaking of wire inside the fan motor Operation stops due to breaking of fan motor lead wires Operation stops due to Hall IC malfunction Operation error due to faulty outdoor unit PCB Troubleshooting ...

Страница 61: ...During heating operation the temperature detected by the indoor pipe temperature sensor is above 60 C Malfunction Caused Clogged air filter of the indoor unit Dust accumulation on the indoor unit heat exchanger Air short circuit Detection error due to faulty indoor pipe temperature sensor Detection error due to faulty indoor unit PCB Troubleshooting ...

Страница 62: ...Decision Conditions Freeze prevention control takes place when indoor pipe temperature is lower than 2 C Malfunction Caused Clogged air filter of the indoor unit Dust accumulation on the indoor unit heat exchanger Air short circuit Detection error due to faulty indoor pipe temperature sensor Detection error due to faulty indoor unit PCB Troubleshooting ...

Страница 63: ...onditions When heating operation when indoor pipe temperature is below 10 C When cooling operation when indoor pipe temperature is above 45 C Malfunction Caused Connector in poor contact Faulty sensor Faulty outdoor unit PCB 4 way valve defective Troubleshooting ...

Страница 64: ...peration of cooling and heating when Power Factor Correction PFC protection circuitry at the outdoor unit main PCB senses abnormal high DC voltage level Malfunction Caused DC voltage peak due to power supply surge DC voltage peak due to compressor windings not uniform Faulty outdoor PCB Troubleshooting ...

Страница 65: ...by checking the CT detected input current value and the compressor running frequency During startup and operating of cooling and heating input current 8 78 256 A Hz compressor running frequency 0 25 Gas shortage detection 2 A gas shortage is detected by checking the difference between indoor pipe temperature and indoor intake air temperature during cooling and heating Malfunction Caused Refrigeran...

Страница 66: ...alfunction Decision Conditions A compressor rotation failure is detected by checking the compressor running condition through the position detection circuit Malfunction Caused Compressor terminal disconnect Outdoor PCB malfunction Troubleshooting ...

Страница 67: ...s detected by the outdoor pipe temperature sensor Malfunction Caused Outdoor pipe temperature rise due to short circuit of hot discharge air flow Outdoor pipe temperature rise due to defective of outdoor fan motor Outdoor pipe temperature rise due to defective outdoor pipe temperature sensor Outdoor pipe temperature rise due to defective outdoor unit PCB Troubleshooting ...

Страница 68: ...vated Heat Sink Overheating During operation of cooling and heating when heat sink temperature data 90 C is detected by the heat sink temperature sensor Malfunction Caused IPM overheats due to short circuit of hot discharge air flow IPM overheats due to defective of outdoor fan motor IPM overheats due to defective of internal circuitry of IPM IPM overheats due to defective IPM temperature sensor M...

Страница 69: ...on of cooling and heating when compressor tank temperature data 112 C is detected by the compressor tank temperature sensor Malfunction Caused Refrigerant shortage refrigerant leakage 2 3 way valve closed Detection error due to faulty compressor tank temperature sensor Troubleshooting ...

Страница 70: ... detected by checking the input current value being detected by current transformer CT with the compressor running Malfunction Caused Over current due to compressor failure Over current due to defective outdoor unit PCB Over current due to defective inverter main circuit electrolytic capacitor Over current due to excessive refrigerant Troubleshooting ...

Страница 71: ...peak due to compressor failure DC peak due to defective power transistor s DC peak due to defective outdoor unit PCB Troubleshooting Checking the power transistor Never touch any live parts for at least 10 minutes after turning off the circuit breaker If unavoidable necessary to touch a live part make sure the power transistor s supply voltage is below 50V using the tester For the UVW make measure...

Страница 72: ...or Removal Procedures 16 1 1 To remove front grille 16 1 2 To remove horizontal vane WARNING High Voltage are generated in the electrical parts area by the capacitor Ensure that the capacitor has discharged sufficiently before proceeding with repair work Failure to heed this caution may result in electric shocks ...

Страница 73: ...73 16 1 3 To remove power electronic controller ...

Страница 74: ...74 16 1 4 To remove discharge grille 16 1 5 To remove control board ...

Страница 75: ...75 16 1 6 To remove cross flow fan and indoor fan motor ...

Страница 76: ...76 ...

Страница 77: ...Top Panel Fig 1 2 Remove the 10 screws of the Front Panel Fig 2 3 Remove the Top Cover of the Electronic Controller Fig 3 4 Remove the Control Board Fig 4 5 Remove the 8 screws of the Electronic Controller Fig 5 Caution When handling electronic controller be careful of electrostatic discharge ...

Страница 78: ...tion Characteristics 17 1 1 CS RE18JKX 1 CU RE18JKX 1 Cooling Characteristic at Different Outdoor Air Temperature Condition Indoor room temperature 27 19 C Remote control setting HI FAN COOL 16 C Compressor frequency Fc Voltage 230 V ...

Страница 79: ...79 Cooling Characteristic at Different Piping Length Condition Indoor room temperature 27 19 C 35 C Remote control setting HI FAN COOL 16 C Compressor frequency Fc Voltage 230 V ...

Страница 80: ...80 Heating Characteristic at Different Outdoor Air Temperature Condition Indoor room temperature 20 C Remote control setting HI FAN HEAT 30 C Compressor frequency Fh Voltage 230 V ...

Страница 81: ...81 Heating Characteristic at Different Piping Length Condition Indoor room temperature 20 C 7 6 C Remote control setting HI FAN HEAT 30 C Compressor frequency Fh Voltage 230 V ...

Страница 82: ... 2 CS RE24JKX 1 CU RE24JKX 1 Cooling Characteristic at Different Outdoor Air Temperature Condition Indoor room temperature 27 19 C Remote control setting HI FAN COOL 16 C Compressor frequency Fc Voltage 230 V ...

Страница 83: ...83 Cooling Characteristic at Different Piping Length Condition Indoor room temperature 27 19 C 35 C Remote control setting HI FAN COOL 16 C Compressor frequency Fc Voltage 230 V ...

Страница 84: ...84 Heating Characteristic at Different Outdoor Air Temperature Condition Indoor room temperature 20 C Remote control setting HI FAN HEAT 30 C Compressor frequency Fh Voltage 230 V ...

Страница 85: ...85 Heating Characteristic at Different Piping Length Condition Indoor room temperature 20 C 7 6 C Remote control setting HI FAN HEAT 30 C Compressor frequency Fh Voltage 230 V ...

Страница 86: ...1 58 4 31 3 47 1 70 22 0 C 5 94 4 08 1 40 5 55 3 93 1 50 5 16 3 79 1 61 4 69 3 61 1 73 Outdoor Temp C Indoor wet bulb temp 30 35 40 46 TC SHC IP TC SHC IP TC SHC IP TC SHC IP 17 0 C 6 75 5 11 1 94 6 30 4 90 2 09 5 86 4 71 2 23 5 33 4 48 2 41 19 0 C 6 80 2 12 19 5 C 7 41 5 35 1 98 6 92 5 14 2 13 6 44 4 95 2 28 5 85 4 71 2 45 22 0 C 8 07 5 55 2 01 7 54 5 34 2 17 7 02 5 15 2 32 6 38 4 91 2 50 TC SHC ...

Страница 87: ...87 18 Exploded View and Replacement Parts List 18 1 Indoor Unit ...

Страница 88: ...RUM 2 CWH621103 25 VERTICAL VANE 15 CWE241289 26 CONNECTING BAR 1 CWE261156 27 CONNECTING BAR 1 CWE261158 28 CONNECTING BAR 1 CWE261157 29 CONNECTING BAR 1 CWE261159 30 CONNECTING BAR 1 CWE261160 31 AIR SWING MOTOR 1 CWA98K1014 O 32 AIR SWING MOTOR 1 CWA981241 O 33 LEAD WIRE AIR SWING MOTOR 1 34 CAP DRAIN TRAY 1 CWH521096 35 HORIZONTAL VANE 1 CWE24C1295 36 BACK COVER CHASSIS 1 CWD933031 37 REMOTE ...

Страница 89: ...89 18 2 CU RE18JKX 1 Note The above exploded view is for the purpose of parts disassembly and replacement The non numbered parts are not kept as standard service parts ...

Страница 90: ...1 CWA50C2185 26 HOLDER SENSOR 1 CWH32074 27 V COIL COMPLETE FOR 4 WAY VALVE 1 CWA43C2168J 28 V COIL COMPLETE FOR EXP VALVE 1 CWA43C2058J 29 SENSOR CO OUTDOOR DISCHARGE TEMP 1 CWA50C2180 30 SENSOR CO OUTDOOR AIR TEMP AND HEAT EXCHANGE TEMP 1 CWA50C2181 O 31 REACTOR 1 G0C203J00003 33 TERMINAL BOARD ASSY 1 CWA28K1110J 35 FUSE CAP TERMINAL 1 K5D303BBA002 36 FUSE HOLDER 1 K3GB1PH00016 37 EXPANSION VALV...

Страница 91: ...91 Note All parts are supplied from PHAAM Malaysia Vendor Code 00029488 O marked parts are recommended to be kept in stock 62 RECEIVER 1 CWB14011 REF NO PART NAME DESCRIPTION QTY CU RE18JKX 1 REMARKS ...

Страница 92: ...92 18 3 CU RE24JKX 1 Note The above exploded view is for the purpose of parts disassembly and replacement The non numbered parts are not kept as standard service parts ...

Страница 93: ... 25 3 WAYS VALVE GAS 1 CWB011363 O 26 2 WAYS VALVE LIQUID 1 CWB021434 O 27 SOUND PROOF BOARD 1 CWH151197 28 TERMINAL COVER 1 CWH171039A 29 NUT TERMINAL COVER 1 CWH7080300J 30 SENSOR COMPLETE COMP TOP 1 CWA50C2185 31 HOLDER SENSOR 1 CWH711010 32 V COIL COMPLETE 1 CWA43C2169J 34 SENSOR CO COMP DISCHARGE 1 CWA50C2515 35 SENSOR COMPLETE 1 CWA50C2517 36 REACTOR 2 G0C403J00001 37 CONTROL BOARD CASING SI...