Split System Submittal Data
Indoor:
CS-MKS24NKU
Multi System Indoor Units - Wall Mounted
Approval:
Date:
Construction:
Unit#:
Drawing#:
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
General Data
Power (V/P/Hz)
208 - 230/1/60
Circuit Ampacity (A)
15
Fuse Size, Max.(A)
20
Running Amps (A)
0.20
Power Input (W)
45
Indoor Unit
Fan type
Cross Flow
Dia & Length (in.) - No. Speeds
D3-11/16 L33-9/32 -1
No. Speeds
3 & Auto
No. Poles (RPM, High)
8 - (1300)
No. Motors (W)
1-(30)
CFM (HI)
541
Operation Sound (HI/Med/Lo/
QT*dB-A)
44/41/38/30
Coil Type
Aluminum Plate Fin & Copper
Tube
Fin Type - Pipe Type
Slit Plate - Inner Rifled
Rows - F.P.I.
2 - 19.5
Face Area (sq.ft.)
3.07
Tube Size (in)
9/32
Drain Connection Size
23/32
Refrigerant
R410A
Line Size (in. O.D. Discharge)
1/4” (Flare)
Line Size (in. O.D. Discharge)
5/8” (Flare)
Dimensions (HxWxD)
Indoor Unit (Crated) (in.)
11-3/8 x 44-7/8 x 14-29/32
Indoor Unit (Uncrated) (in.)
11-23/32 x 41-15/16 x 8-19/32
Weight (lbs.)
Indoor
Net
24.5
Shipping
33.1
Shipping Volume (cu.ft.)
4.23
Performance Data @ ARI Standard Conditions (230V)
Cooling
Total Capacity (BTU/H)
24200
Moisture Removal (HI, Pint/H)
4.89
Features
Controls
Microprocessor
Remote Control
LCD Wireless Type, Built-in Temp
Sensor
Temperature Control
IC Thermostat
Timer
24 Hr. Program, 1 Hr. Off
Night Setback
Built-In
Air Louver, Horizontal
Manual
Air Louver, Vertical
Automatic
Power Failure Automatic Restart
Built-In
Heating/Cooling Automatic
Changeover
Self-Diagnosis
Built-In
Quiet Operation
Built-In
Air Filter
Washable, Anti-Mold
Ion Generator
N/A
Air Clean Apatite Filer
N/A
Option
Refrigerant Line Set
Available
Fresh Air Intake
N/A
Airduct Extension
N/A
Indoor Frame Extension
N/A
Condensate Drain Pump
Available
Non-Removeable Remo-con
Bracket
Available
Operating Range
Indoor Air Intake Temp Outdoor Air Intake Temp
Cooling (Max)
95F DB/71F WB
115F DB
Cooling (Min)
67F DB/57F WB
14F DB