11.2.7 Disposal of Outdoor Unit Drain Water
If a drain elbow is used, the unit should be placed on a stand which is taller than 1-3/16" (3 cm).
If the unit is used in an area where temperature falls below 32°F (0°C) for 2 or 3 days in succession, it is
recommended not to use a drain elbow, for the drain water freezes and the fan will not rotate.
11.2.8 Auto Switch Operation
The following operations can be performed by
pressing the “AUTO” switch.
1 AUTO OPERATION MODE
The Auto operation will be activated
immediately once the Auto Switch is pressed.
2 TEST RUN OPERATION (FOR PUMP
DOWN/SERVICING PURPOSE)
The Test Run operation will be activated if the
Auto Switch is pressed continuously for more
than 5 sec. to below 8 sec. A “pep” sound will
occur at the fifth sec., in order to identify the
starting of Test Run operation.
Hose
Install the hose at an
angle so that the water
smoothly flows out.
Drain elbow
“AUTO” switch