background image

3TR006602BAA

Operating Instructions

<Operations and Settings>

Remote Camera Controller

Model No.  

AW-RP50N

Содержание AWRP50N - REMOTE CAMERA CONTROLLER

Страница 1: ...3TR006602BAA Operating Instructions Operations and Settings Remote Camera Controller Model No AW RP50N ...

Страница 2: ...750 AW IF400G AW IF400 AW HE50SN AW HE50 AW E860N AW E860 AK HC1500G AK HC1500 AW HE100N AW HE100 AW PH360N AW PH360 AK HC1800G AK HC1800 AW HE870N AW HE870 AW PH400P AW PH400 AW E350P AW E350 AW PH405N AW PH405 In these instructions the phrases pan tilt head and camera combination and camera integrated with a pan tilt head are both referred to collectively as remote camera except in places where ...

Страница 3: ... LIABLE TO ANY PARTY OR ANY PERSON EXCEPT FOR REPLACEMENT OR REASONABLE MAINTENANCE OF THE PRODUCT FOR THE CASES INCLUDING BUT NOT LIMITED TO BELOW ANY DAMAGE AND LOSS INCLUDING WITHOUT LIMITATION DIRECT OR INDIRECT SPECIAL CONSEQUENTIAL OR EXEMPLARY ARISING OUT OF OR RELATING TO THE PRODUCT PERSONAL INJURY OR ANY DAMAGE CAUSED BY INAPPROPRIATE USE OR NEGLIGENT OPERATION OF THE USER UNAUTHORIZED D...

Страница 4: ... R B GAIN R B PED SYSTEM SETUP CAMERA SCENE MODE DETAIL DELETE STORE PAGE MENU F2 EXIT USER2 USER1 PT ACTIVE AUTO IRIS CAMERA STATUS SELECTION PRESET MEMORY MENU GAIN PED F2 F1 1 2 3 AWB ABB 4 SHUTTER 5 1 2 3 4 5 6 7 8 9 10 CAM100 AW HE50 POWER ON 1 2 Turning on the power of a multiple number of cameras 1 Set the MENU button to ON Press the MENU button to light its indicator 2 Set PRESET MEMORY ME...

Страница 5: ...R B GAIN R B PED SYSTEM SETUP CAMERA SCENE MODE DETAIL DELETE STORE PAGE MENU F2 EXIT USER2 USER1 PT ACTIVE AUTO IRIS CAMERA STATUS SELECTION PRESET MEMORY MENU GAIN PED F2 F1 1 2 3 AWB ABB 4 SHUTTER 5 1 2 3 4 5 6 7 8 9 10 CAM100 AW HE50 POWER OFF 1 2 Turning off the power of a multiple number of cameras 1 Set the MENU button to ON Press the MENU button to light its indicator 2 Set PRESET MEMORY M...

Страница 6: ...emory is specified For details on the relationship between the Preset number Page number and Number on the page refer to the section entitled Preset numbers and registered pages 5 Hold down the PRESET MEMORY MENU button to specify the Number on the page The preset memory data is registered at the same time as the Number on the page is specified When specifying the Number on the page hold down the ...

Страница 7: ... turned off or when the camera group has been switched In the case of the AW HE50 the corresponding PRESET MEMORY MENU button will go off and then it will light again when preset memory data is executed In the case of another remote camera connected serially the corresponding PRESET MEMORY MENU button will simply just light Deleting the preset memory data This function does not work with the AW PH...

Страница 8: ...ON When the button is pressed and its indicator lights the GAIN PED menu is displayed on the LCD panel 3 Turn the F1 dial to select the setting GAIN 0dB PED 0 GAIN 3dB PED 0 Turn the F1 dial The settings will differ depending on the remote camera connected For further details check the Operating Instructions of the model concerned Note Setting the pedestal Perform the black level pedestal adjustme...

Страница 9: ...the PRESET MEMORY MENU 4 button AWB ABB to ON When the button is pressed and its indicator lights the AWB ABB menu is displayed on the LCD panel 3 Turn the F1 dial to select the white balance mode AWB MOD AWB B SET AWB The modes which can be selected differ depending on the remote camera connected Remote camera Mode Remote camera status AW HE50 AWB A The status of the white balance registered in r...

Страница 10: ...e white balance is stored AWB MOD AWB A SET AWB This step need not be taken when the AK HC1500 or AK HC1800 is used as the remote camera 4 Turn the F2 dial to select AWB and press the F2 dial The remote camera now automatically adjusts the white balance and registers it at the place selected in step 3 When automatic adjustment is performed the following details are displayed on the LCD panel AWB A...

Страница 11: ...Instructions of the model concerned Note Auto tracking white adjustment ATW This function provides compensation automatically so that the white balance is adjusted even when the light source or color temperature changes during shooting so that images that appear the least odd that is the most natural looking are produced 1 Set the MENU button to ON Press the MENU button to light its indicator 2 Se...

Страница 12: ...dial AWB MOD AWB B SET ABB The remote camera now automatically adjusts the black balance When automatic adjustment is performed the following details are displayed on the LCD panel ABB ACTIVE This appears while ABB is being executed ABB OK This appears for 3 seconds after ABB was completed successfully ABB NG This appears for 3 seconds after ABB was completed unsuccessfully The settings will diffe...

Страница 13: ...he Operating Instructions of the model concerned When a remote camera connected serially is selected and its shutter speed is set and then a remote camera in another group is assigned to the CAMERA STATUS SELECTION button the shutter speed will be set to 1 100 when a menu operation is next performed Notes Setting the detail The image detail image sharpness can be adjusted 1 Set the MENU button to ...

Страница 14: ...n the F1 dial to select the shooting mode SCENE MANU1 MODE CAM The settings will differ depending on the remote camera connected For further details check the Operating Instructions of the model concerned Note Specifying the color bars The images to be output from the remote camera can be switched between the camera images and color bars 1 Set the MENU button to ON Press the MENU button to light i...

Страница 15: ...1 dial Enters the setting AK HC1500 AK HC1800 AW HE870 Hold down the CAMERA OSD button Turn the F1 dial Turn it clockwise Moves downward to an item Changes decrements the setting Turn the F1 dial Turn it counterclockwise Moves upward to an item Changes increments the setting Press the F1 dial Enters the setting AW E350 AW E650 AW E750 AW E860 AW HE100 Hold down the CAMERA OSD button Turn the F1 di...

Страница 16: ... the remote camera selected to the switcher On Enable Off Disable AWB AWB is executed when the USER button in which AWB has been assigned is pressed When AWB is executed successfully the indicator of the button goes off conversely when it is not executed successfully it blinks ABB ABB is executed when the USER button in which ABB has been assigned is pressed When ABB is executed successfully the i...

Страница 17: ...ght its indicator 2 Set PRESET MEMORY MENU 8 button CAMERA to ON When the button is pressed and its indicator is lighted the CAMERA menu is displayed on the LCD panel 1 GROUP 3 Turn the F1 dial to display the TALLY menu and press the F1 dial 3 TALLY 1 TALLY OUT Off Press the F1 dial 4 Turn the F2 dial to select On or Off and then press the F2 dial to enter the selection 1 TALLY OUT Off 1 TALLY OUT...

Страница 18: ...ttings are established using the SETUP menu First the basic menu operations will be described 1 Set the MENU button to ON Press the MENU button to light its indicator 2 Set the PRESET MEMORY MENU 9 button SETUP to ON When the button is pressed and its indicator lights the SETUP menu is displayed on the LCD panel 1 USER 3 Turn the F1 dial to display the target menu item and press the F1 dial For de...

Страница 19: ...o the vertical manipulation of the PAN TILT lever When NORMAL is selected as the setting the remote camera will move upward when the PAN TILT lever is leaned away from you and conversely it will move downward when the lever is leaned toward you When REVERSE is selected the remote camera will move in the opposite directions Setting the zooming direction From the SETUP menu select OPERATE and displa...

Страница 20: ...ming and focusing P T The operation speed setting takes effect for panning and tilting Switching from focus control to iris control or vice versa It is possible to switch the control which is implemented by dial and button operations from focus control to iris control or vice versa AUTO IRIS AUTO HI LOW PTZ FOCUS SPEED PA FOCUS PUSH OTAF TELE ZOOM WIDE CAMERA STATUS SELECTION 1 2 3 4 5 From the SE...

Страница 21: ...ris gain white balance MODE B Pan tilt zoom focus iris MODE C Pan tilt zoom This function takes effect when the unit is connected to the AW HE50 It does not work with any other models Note Returning the remote cameras to their home position The remote cameras connected can be returned to their home position From the SETUP menu select PRESET and display HOME POSITION Then press the F2 dial 3 HOME P...

Страница 22: ... in front of the obstruction to prevent contact Setting the upper limit From the SETUP menu select PTZ ADJ and display LIMIT UP Then set the upper limit The setting that is displayed differs between the AW HE50 and other remote cameras Display that appears with the AW HE50 The current setting status is displayed in the LIMIT UP item 2 LIMIT UP Off 2 LIMIT UP On Turn the F2 dial and then press it D...

Страница 23: ...e completion of the setting in the LIMIT LEFT item 4 LIMIT LEFT EXEC 4 LIMIT LEFT LIMIT ON Press the F2 dial Setting the right limit From the SETUP menu select PTZ ADJ and display LIMIT RIGHT Then set the right limit The setting that is displayed differs between the AW HE50 and other remote cameras Display that appears with the AW HE50 The current setting status is displayed in the LIMIT RIGHT ite...

Страница 24: ...tem is used to control a defroster when using a remote camera AW PH650 camera equipped with a defroster function as the currently selected remote camera From the SETUP menu select FUNCTION and display DEFROSTER Then select defroster On or Off 3 DEFROSTER Off Controlling a wiper This item is used to control a wiper when using a remote camera AW PH650 camera equipped with a wiper function as the cur...

Страница 25: ... memory data Preset numbers can be assigned to execute presets for the selected remote cameras when signals have been input to the TALLY GPI input output connector The presets are assigned using the GPI item on the SETUP menu 8 GPI Setting the preset numbers From the SETUP menu select GPI and display PRESET CTL1 PRESET CTL2 or PRESET CTL3 Then set the camera number and preset number 1 PRESET CTL1 ...

Страница 26: ...utton operation enable or disable 1 MENU CONTROL ENABLE When DISABLE is selected the following button operations are disabled CAMERA OSD button PRESET MEMORY MENU 1 to 7 buttons However these buttons can still be used to execute preset settings Adjusting the LCD panel backlight The backlight of the LCD panel can be adjusted Make this adjustment using the LCD BL item on the SETUP menu 9 LCD BL Adju...

Страница 27: ...s lighted the SYSTEM menu is displayed on the LCD panel 1 CAMERA CTL 3 Turn the F1 dial display the SW IP ADR menu and press the F1 dial 1 IP SW 192 168 000 008 9 SW IP ADR Press the F1 dial 4 Turn the F2 dial select the IP address and then press the F2 dial to enter the selection Set the IP address which has been set in the switcher 1 IP SW 192 168 000 020 1 IP SW 172 168 000 020 Turn the F2 dial...

Страница 28: ...u is displayed on the LCD panel 1 USER 3 Turn the F1 dial display the SW LINK menu and press the F1 dial 2 SW LINK 1 SWLINK Off Press the F1 dial 4 Turn the F2 dial to select On and then press the F2 dial to change the setting 1 SWLINK On When On is selected as the item setting the settings mentioned below take effect and the link with the switcher is established Control can also be exercised by a...

Страница 29: ... ON When the button is pressed and its indicator is lighted the SYSTEM menu is displayed on the LCD panel 1 CAMERA CTL 3 Turn the F1 dial display the SW ASSIGN menu and press the F1 dial 4 SW ASSIGN 1 INPUT1 CAM1 Press the F1 dial 4 Turn the F1 dial to select the input line of the switcher 2 INPUT2 CAM1 1 INPUT1 CAM1 Turn the F1 dial 5 Turn the F2 dial select the remote camera and then press the F...

Страница 30: ... the LCD panel 1 USER 3 Turn the F1 dial display the SW LINK menu and press the F1 dial 2 SW LINK 1 SWLINK Off Press the F1 dial 4 Turn the F1 dial to select the menu item to be set 1 SWLINK Off 2 BUSCONT Off Turn the F1 dial 5 Turn the F2 dial select the settings and then press the F2 dial to change the setting 2 BUSCONT Off 2 BUSCONT On Turn the F2 dial and then press it Bus switching From the S...

Страница 31: ...splay FASIST Then set On or Off 4 FASIST Off When On is selected as this item s setting the images of the AUX bus output from the switcher will be switched to the images of the remote camera selected by the unit Conversely when Off is selected the switcher will switch the images of the AUX bus output from the switcher to the images of its multi view display Camera information setting From the SETU...

Страница 32: ...4 Input5 CAM5 GPI Input Group 1 Group 2 In response to inputs 1 to 5 from GPI Input tally indicators CAM1 to CAM5 are lighted in red and the tally ON instruction is sent to the remote cameras concerned Only CAM1 to CAM5 serve as the GPI Input tally This means that when a camera group other than No 1 is selected the tally indicators will go off The following tally related settings can be establishe...

Страница 33: ...ss the F1 dial 3 SW DISP 1 CAMINF Off Press the F1 dial 4 Turn the F1 dial to and select the menu item to be set 1 CAMINF Off 2 FORMAT Off Turn the F1 dial 5 Turn the F2 dial to select On or Off and then press the F2 dial to enter the selection 2 FORMAT Off 2 FORMAT On Turn the F2 dial and then press it Setting all the information displays together From the SETUP menu select SW DISP and display CA...

Страница 34: ...ISP and display SCENE Then set On or Off 4 SCENE Off Gain value From the SETUP menu select SW DISP and display GAIN Then set On or Off 5 GAIN Off Shutter information From the SETUP menu select SW DISP and display SHUTTER Then set On or Off 6 SHUTTER Off Iris value From the SETUP menu select SW DISP and display IRIS Then set On or Off 7 IRIS Off Filter information From the SETUP menu select SW DISP...

Страница 35: ...ote camera item CAM1 to CAM100 The alarm status is displayed underneath 2 CAM1 FAN ALM 1 POWER No ALARM Turn the F2 dial Select POWER The unit s power supply alarm can be checked No ALARM When the power supply is trouble free ALARM When trouble has occurred in the power supply Select CAM1 to CAM100 The alarm statuses of the remote cameras currently assigned to the CAMERA STATUS SELECTION buttons a...

Страница 36: ...indicator is lighted the SYSTEM menu is displayed on the LCD panel 1 CAMERA CTL 3 Turn the F1 dial to display the INITIALIZE menu and press the F1 dial 11 INITIALIZE 1 INITIALIZE ALL Press the F1 dial 4 Turn the F2 dial to select the initializing mode 1 INITIALIZE SETUP 1 INITIALIZE ALL Turn the F2 dial ALL The settings controlled by the unit are returned to the factory statuses SETUP Only the set...

Страница 37: ...nd 4 GPI IN 1 Preset input 1 Contact input 12 GPI IN 2 Preset input 2 5 GPI IN 3 Preset input 3 13 GPI IN 4 Panel lock 6 GPI OUT 1 Remote camera selection 0 Open collector output 14 GPI OUT 2 Remote camera selection 1 7 GPI OUT 3 Remote camera selection 2 15 GPI OUT 4 Alarm 8 NC Not used GND GPI OUT LED Example of GPI OUT connections Ensure that the conditions given below are satisfied Dielectric ...

Страница 38: ... not perform the operation at the unit Do not start up the Setup Software in any other computer in the same network Do not use the Easy IP Setup Software which is provided with the AW HE50 Notes Installing the software This section describes how to install the Setup Software 1 Insert the CD ROM provided with the unit into the CD ROM drive of the host computer in which the software application is g...

Страница 39: ...l connection they are displayed only when the cameras are selected by the unit SW Input The input connectors of the switcher are displayed in this column The input connector can be changed manually Click on the right and select NoAsign or an input connector from INPUT1 to INPUT5 After the connector has been changed click the SET button to reflect the change MAC Address The MAC addresses of the rem...

Страница 40: ...of the device concerned into the IP Address box 2 Click SET The changed IP address now takes effect Changing the camera numbers The camera numbers set for the remote cameras can be changed 1 Change the camera number for the remote camera concerned in the CAMERA Select box 2 Click SET The changed camera number now takes effect Registering the camera numbers in the switcher s input connectors Set th...

Страница 41: ...le has been loaded a message is displayed to alert the user to the fact that loading is completed Saving the log files Save the log files Filename RP50 log 1 Click Save The file save screen now appears 2 Specify the save destination and filename and click Save Memo If the same information on the settings for the connections with the remote cameras is shared among a multiple number up to 5 units of...

Страница 42: ...lected AW RP50 units can be referenced using the Setting tab Up to five AW RP50 units can be selected 1 Enter the IP addresses in the AW RP50 IP ADDRESS boxes In boxes RP1 to RP5 enter the IP addresses of the AW RP50 units whose data is to be referenced 2 Click Set 3 In the list box of the Setting tab select the AW RP50 whose data is to be referenced The information of the network environment crea...

Страница 43: ...0 30 to 30 AW HE870 150 to 150 AW E860 AW E750 AW E650 AW E350 150 to 150 AK HC1500 AK HC1800 150 to 150 BGAIN AW HE50 AW HE100 30 to 30 AW HE870 150 to 150 AW E860 AW E750 AW E650 AW E350 150 to 150 AK HC1500 AK HC1800 150 to 150 3 R BPED RPED AW HE50 AW HE100 AW HE870 150 to 150 AW E860 AW E750 AW E650 AW E350 150 to 150 AK HC1500 AK HC1800 100 to 100 BPED AW HE50 AW HE100 AW HE870 150 to 150 AW...

Страница 44: ... AK HC1500 AK HC1800 VIDEO 1 100 1 120 1 250 1 500 1 1000 1 2000 second FILME 180 0 172 8 144 0 120 0 90 0 45 0 degree 6 DETAIL DETAIL Off On LEVEL AW HE50 LOW HIGH AW HE100 0 to 14 AW HE870 LOW HIGH AW E860 AW E750 AW E650 AW E350 LOW HIGH AK HC1500 AK HC1800 7 SCENE MODE SCENE AW HE50 F AUTO MANU1 MANU2 MANU3 AW HE100 HALOGEN FLUORE DAYLIGHT USER AW HE870 HALOGEN FLUORE OUTDOOR USER AW E860 AW E...

Страница 45: ... On Off On 5 GAIN On Off On 6 SHUTTER On Off On 7 IRIS On Off On 8 FILTER On Off On 9 ALARM On Off On 4 OPERATE 1 PAN DIR NORMAL NORMAL REVERSE 2 TILT DIR NORMAL NORMAL REVERSE 3 ZOOM DIR NORMAL NORMAL REVERSE 4 FOCUS DIR NORMAL NORMAL REVERSE 5 SPEED WITH Z AW HE50 Off On AW HE100 Off 1 2 AW PH360 AW PH400 AW PH405 AW PH650 Off 1 2 6 SPEED TARGET P T Z F P T Z F P T 7 FOCUS IRIS STANDARD STANDARD...

Страница 46: ...405 Off On AW PH650 Off On 6 LAMP AW HE50 AW HE100 AW PH360 AW PH400 AW PH405 Off On AW PH650 Off On 7 PTZ ADJ 1 Z MIN SPEED Off Off 1 to 8 2 LIMIT UP AW HE50 Off On AW HE100 EXEC AW PH360 AW PH400 AW PH405 AW PH650 EXEC 3 LIMIT DOWN AW HE50 Off On AW HE100 EXEC AW PH360 AW PH400 AW PH405 AW PH650 EXEC 4 LIMIT LEFT AW HE50 Off On AW HE100 EXEC AW PH360 AW PH400 AW PH405 AW PH650 EXEC 5 LIMIT RIGHT...

Страница 47: ...EAR 6 NETWORK 1 IP ADDRESS 192 168 000 009 2 SUBNETMASK 255 255 255 000 3 GATEWAY 192 168 000 001 4 MAC ADDRESS Display only 7 CAM IP ADR 1 IP CAM1 to 100 IP CAM100 192 168 000 010 to 192 168 000 109 8 CAM PORT 1 PORT CAM1 to 100 PORT 100 80 1 to 65535 9 SW IP ADR 1 IP SW 192 168 000 008 10 ALARM 1 POWER ALARM No ALARM 2 CAM Note FAN ALM P T ALM FAN ALM P T ALM No ALARM 3 CAM Note 4 CAM Note 5 CAM...

Страница 48: ...F0610Y1070 D Panasonic System Networks Co Ltd 2010 ...