9.
Service switches <SERVICE>
Perform switch settings before turning the unit on.
RS-422
3G SDI OUT
AUDIO IN
LAN
LINK
ACT
DC IN
12V
SERVICE
Service switches
Function
Factory settings
SW1
Switches for initialization
(Refer to the explanations in “Initialization 1”
and “Initialization 2”)
OFF
SW2
OFF
(Use both switches SW1 and SW2 to execute Initialization 1 and
Initialization 2.)
Initialization 1
• Reset the user authentication settings and host authentication
settings for network connection.
(This will delete all the registered user information (IDs/passwords)
and host information (IP addresses).)
• With the service switches set as shown below, turn on the power of
the unit.
SW1
ON
OFF
SW2
<NOTE>
• When initialization is complete, the status display lamp on the
front of the unit blinks green. Set the service switches back to their
original positions (SW1 and SW2 both OFF), then restart the unit.
Initialization 2
• The unit is reset to the state it was in at the time of purchase. (All
camera menu setting values and network setting values are reset.)
• With the service switches set as shown below, turn on the power of
the unit.
SW1
ON
OFF
SW2
<NOTE>
• When initialization is complete, the status display lamp on the
front of the unit blinks green. Set the service switches back to their
original positions (SW1 and SW2 both OFF), then restart the unit.
10.
Cable clamp
This is used to hold the cable connection to the DC IN connector and
prevent it from becoming disconnected.
11.
DC IN connector <12V IN
>
Connect the AC adaptor supplied with the unit to this connector to
supply the DC 12 V voltage to the unit.
AC adaptor
Be sure to use the supplied AC adaptor.
12.
RS‑422 connector <RS‑422>
This RS-422 connector (RJ-45) is connected when exercising serial
control over the unit from an external device. Use a cable with the
following specifications for the connection to this connector.
Furthermore, by shorting the R-TALLY signal (2-pin) with the GND
(1-pin), it is possible to light the tally lamp (red) in the camera head
section of the unit.
<NOTE>
• Do not connect PoE cable to the RS-422 port.
• Do not apply a voltage to the R_TALLY_IN signal pin.
• [AW‑UE50]
The ON/OFF for red tally signals or green tally signals received by
this unit can be output via pin 7 or pin 8.
[AW‑UE40]
The ON/OFF for red tally signals received by this unit can be output
via pin 7.
Output is by contact output, and normally is “OPEN”, then it
becomes “MAKE” for output. (→ page 59)
LAN cable
*
1
(category 5e or above, STP, straight cable),
max. 1000 m (3280 ft)
*
1
Use of an STP (shielded twisted pair) cable is recommended.
[AW‑UE50]
Pin
No.
Signal
Pin
No.
Signal
1
GND
5
TXD+
2
R_TALLY_IN
6
RXD+
3
RXD–
7
OPTION_OUT1
4
TXD–
8
OPTION_OUT2
[AW‑UE40]
Pin
No.
Signal
Pin
No.
Signal
1
GND
5
TXD+
2
R_TALLY_IN
6
RXD+
3
RXD–
7
R_TALLY_OUT
4
TXD–
8
―
Example OPTION_OUT1, OPTION_OUT2 connector
connections
AW-UE50
OPTION_OUT1
OPTION_OUT2
GND
Voltage: Maximum DC12 V
Current: Maximum 50 mA
Example R_TALLY_OUT connector connections
AW-UE40
R_TALLY_OUT
GND
Voltage: Maximum DC12 V
Current: Maximum 50 mA
13.
AUDIO IN connector <AUDIO IN>
Inputs external audio (microphone, line).
14.
Ground connector
Connects to the ground connector on a wall outlet, ground bar, etc.
for grounding. (→ page 6)
16
17
Parts and their functions (continued)
Содержание AW-UE50WP
Страница 153: ...153 MEMO ...