89
Controls and settings from web screen
(continued)
Subnet mask
<Initial setting: 255.255.255.0>
Input the unit’s subnet mask here if the DHCP function is
not going to be used.
Default gateway
<Initial setting: 192.168.0.1>
Input the unit’s default gateway if the DHCP function is not
going to be used.
●
●
Multiple IP addresses cannot be used for the default
gateway even when the DHCP function is used.
For details on the DHCP server settings, consult your
network administrator.
DNS
<Initial setting: Manual>
Whether the DNS server address is to be acquired
automatically (Auto) or manually (Manual) is input here.
If “Manual” has been selected, the DNS settings must be
established.
If “Auto” is selected when the DHCP function is going
to be used, the DNS server address is acquired
automatically.
For further details, consult your system administrator.
Primary server address
Secondary server address
<Initial setting: blank>
Input the IP address of the DNS server if the “Manual”
setting has been selected for “DNS”.
For details on the IP address of the DNS server, consult
your system administrator.
HTTP port [1 to 65535]
<Initial setting: 80>
The port number is allocated here separately.
The following port numbers are used by the unit therefore
cannot be used.
Port numbers already used
20, 21, 23, 25, 42, 53, 67, 68, 69,
110, 123, 161, 162, 554, 995, 10669, 10670,
59000 to 59999, 60000 to 61000
Line speed
<Initial setting: Auto>
Select one of the following data line speeds.
Normally, it is recommended that the “Auto” default setting
be used.
Auto
The line speed is set automatically.
100 M-Full The line speed is set to 100 Mbps full duplex.
100 M-Half The line speed is set to 100 Mbps half
duplex.
10 M-Full
The line speed is set to 10 Mbps full duplex.
10 M-Half The line speed is set to 10 Mbps half duplex.
●
Bandwidth control(bit rate)
<Initial setting: Unlimited>
Select one of the following data bandwidth settings.
Unlimited
384 kbps
2048 kbps
64 kbps
512 kbps
4096 kbps
128 kbps
768 kbps
8192 kbps
256 kbps
1024 kbps
●
Easy IP Setup accommodate period
<Initial setting: Unlimited>
Select “20min” or “Unlimited” as the time for enabling the
operation of the network settings from the Easy IP Setup
Software.
20min
The setting operations from the Easy IP
Setup Software are enabled for 20 minutes
after the camera has started operating.
Unlimited The setting operations from the Easy IP
Setup Software are enabled at all times.
Содержание AW?HE60HE
Страница 119: ...119 Memo ...
Страница 120: ...Web Site http panasonic net Panasonic Corporation 2012 ...