Controls and settings from web screen
(continued)
IR Control [Disable, Enable]
“Enable” or “Disable” is set here for operations conducted
from the wireless remote control.
The operations are enabled when the unit’s power is
turned on from an external device other than a wireless
remote control, and they are disabled when the power is
turned on from a wireless remote control.
●
At the point when this item’s setting is changed, the
new setting is not reflected in operation.
It is reflected when the unit is set to standby mode
and its power is turned on.
●
Follow one of the procedures below if the item’s
setting is changed by mistake and the unit can no
longer be operated from a wireless remote control.
When menu operations can be performed using
another control device:
First change the item using a control device
capable of performing menu operations, and
then turn off the unit’s power and turn it back
on.
When menu operations cannot be performed
using other control devices:
1. Turn off the power of the units and devices that
are connected.
2. Disconnect the unit’s AC adaptor cable and
LAN cable, and plug them back in.
3. Perform the operation for turning on the unit’s
power from the wireless remote control.
4. After changing this item, turn off the unit’s
power and turn it back on.
Notes
IR ID [CAM1, CAM2, CAM3, CAM4]
Configure the unit’s remote control ID.
The settings for this item correspond to the [CAM1] to
[CAM4] buttons on the wireless remote control.
CAM/BAR [Camera, Colorbar]
Switch between color bar display and camera image
display on the monitor and the web setup screen.
●
When the color bar is displayed, a test tone (1 kHz)
is output according to the Audio setting in the
camera menu.
Note
●
OSD Mix
Whether the camera menus, statuses and other displays
are to be turned Off or On can be selected here.
●
This can be configured from the web screen, but the
OSD menu will not be displayed for IP videos.
Note
OSD Off With Tally [Off, On]
This is used to enable or disable the function for clearing
the OSD menu displays when the tally signal is received
by a command or contact.
When the tally signal is released, the original OSD menu
displays are restored.
OSD Status [Off, On]
“Off” or “On” is set here for the status display which
appears during AWB operations.
●
Protocol
Model Select
[SEVIHD1, SBRC300, SBRCZ330, Reserved1 to 7]
Set the protocol model for standard serial communication.
Do not select “Reserved1” to “Reserved7”.