background image

Technical Terminology & Cautions for Use

AECTB36E   201811-T

Usage, storage, and transport conditions (except

turquoise switches)

During usage, storage, or transportation, avoid locations subject
to direct sunlight and maintain normal temperature, humidity,
and pressure conditions.
The allowable specifications for environments suitable for usage,
storage, and transportation are given below.
1) Temperature: The allowable temperature range differs for
each switch, so refer to the switch’s individual specifications. In
addition, when transporting or storing switches while they are
tube packaged, there are cases when the temperature may differ
from the allowable range. In this situation, be sure to consult the
individual specifications.
2) Humidity: The allowable temperature range differs for each
switch, so refer to the switch’s individual specifications.
3) Pressure: 86 to 106 kPa
The humidity range varies with the temperature. Use within the
range indicated in the graph below.

(The allowable temperature depends on the switch.)
• Condensation will occur inside the switch if there is a sudden
change in ambient temperature when used in an atmosphere of
high temperature and high humidity. This is particularly likely to
happen when being transported by ship, so please be careful of
the atmosphere when shipping. Condensation is the
phenomenon whereby steam condenses to cause water
droplets that adhere to the switch when an atmosphere of high
temperature and humidity rapidly changes from a high to low
temperature or when the switch is quickly moved from a low
humidity location to one of high temperature and humidity. 
Please be careful because condensation can cause adverse
conditions such as deterioration of insulation, coil cutoff, and
rust.
• Condensation or other moisture may freeze on the switch when
the temperatures is lower than 0°C 

32°F

. This causes problems

such as sticking of movable parts or operational time lags.
• The plastic becomes brittle if the switch is exposed to a low
temperature, low humidity environment for long periods of time.
• Storage for extended periods of time (including transportation
periods) at high temperatures or high humidity levels or in
atmospheres with organic gases or sulfide gases may cause a
sulfide film or oxide film to form on the surfaces of the contacts
and/or it may interfere with the functions. Check out the
atmosphere in which the units are to be stored and transported.
• In terms of the packing format used, make every effort to keep
the effects of moisture, organic gases and sulfide gases to the
absolute minimum.

 We reserve the right to modify without notice the

materials, internal components, and other parts to improve
product quality.

Handling precautions

When handling the switches, be careful not to drop them on the
floor since this may damage them.

* Select contact sulfurization (clipping) prevention products (FS and Au-clad double 

layer contacts) for use with extremely small loads or an environment-resistant 
Turquoise switch.

Others

1) Failure modes of switches include short-circuiting, open-
circuiting and temperature rises. If this switch is to be used in
equipment where safety is a prime consideration, examine the
possible effects of these failures on the equipment concerned,
and ensure safety by providing protection circuits or protection
devices. In terms of the systems involved, make provision for
redundancy in the design and take steps to achieve safety
design.
2) The ambient operating temperature (and humidity) range
quoted is the range in which the switch can be operated on a 
continuous basis: it does not mean that using the switch within 
the rating guarantees the durability performance and 
environment withstanding performance of the switch. For details 
on the performance guarantee, check the specifications of each 
product concerned.

Tolerance range

(Avoid
condensation when
used at temperatures
higher than 0

°

C

32

°

F

)

(Avoid freezing when
used at temperatures
lower than 0

°

C

32

°

F

)

85

5

–40

–40

0

+32

+85

+185

Temperature, 

°

C

°

F

Humidity, %R.H.

ー 10 ー

Содержание AV4

Страница 1: ...ever 4 Simulated roller lever Contact material Nil Ag plated contact 61 Au plated contact Terminals 0 Solder terminal with mounting holes 1 65 mm dia 4 PC board straight terminal 5 PC board angle terminal Right angle terminal 6 PC board reverse angle terminal Left angle terminal Operating Force OF max by pin plunger 4 0 98 N Type of contacts Actuator Operating Force OF Max Part No PC board termina...

Страница 2: ...ude of 0 75mm contact opening max 1 msec Lever type 10 to 55 Hz at single amplitude of 0 15mm contact opening max 1 msec Shock resistance Pin plunger type Min 294m s2 contact opening max 1 msec Lever type Min 147m s2 contact opening max 1 msec Allowable operation speed 0 1mm s to 500mm s pin plunger type Mechanical max switching frequency 60 operations min Ambient temperature 25 to 80 C no freezin...

Страница 3: ... 08 0 02 3 1 0 dia Pretravel PT Max 0 3 mm Movement Differential MD Max 0 1 mm Overtravel OT Min 0 1 mm Operating Position OP 4 8 0 15 mm Free Position FP Max 5 2 mm 3 95 2 4 Max 3 0 6 5 5 8 7 5 Max FP OP PT 1 7 0 6 0 55 0 55 0 11 0 8 2 5 2 5 0 7 0 7 Note All other dimensions are the same as those of pin plunger type CAD Data Simulated roller lever type External dimensions 6 1 0 7 5 5 2 2 Max 0 6 ...

Страница 4: ...sions Pretravel PT Max 0 3 mm Movement Differential MD Max 0 1 mm Overtravel OT Min 0 1 mm Operating Position OP 4 8 0 15 mm Free Position FP Max 5 2 mm Note All other dimensions of hinge lever type and simulated roller lever type are the same as those of straight terminal types Pin plunger Pin plunger Left angle terminal 3 1 2 4 0 7 0 6 0 5 1 7 0 55 0 55 0 11 0 8 2 5 0 5 0 8 1 9 0 8 1 0 0 6 0 6 5...

Страница 5: ... more than 0 098 N m 2 In setting the movement after operation the over travel should be set within the range of the minimum OT value Please set up so that a operation object does not apply force to the switch body Environment Avoid using and storing these switches in a location where they will be exposed to corrosive gases silicon or high dust levels all of which can have an adverse effect on the...

Страница 6: ...e rated load is connected to the contact and switching operations are performed The life test is performed at a switching frequency of 20 times minute and operating speed of 100 mm second at the regular cam Contact form This refers to the components determining the type of application which make up the electrical input output circuits in the contact Insulation resistance Resistance between non con...

Страница 7: ... stroke setting is the key to high reliability It is also important that adequate contact force be maintained to ensure high reliability For a normally closed NC circuit the driving mechanism should be set so that the actuator is normally in the free position For a normally open NO circuit the actuator should be pressed to 70 to 100 of the specified stroke to absorb possible errors If the stroke i...

Страница 8: ...el load type Contact resistance across COM and NC terminals is measured in the free position while contact resistance across COM and NO terminals is measured in the total travel position 7 To prevent contact welding failure be sure to use a serial resistance for each capacitive load 8 If snap action switch operation is synchronized with the AC supply phase this may cause shortened electrical life ...

Страница 9: ...al portions immediately after soldering The temperature setting and time conditions vary depending on the product See the section CAUTIONS FOR USE for each product Avoid using in a silicon atmosphere Avoid using organic silicon rubber adhesives sealing compounds oil grease and wires in a silicon atmosphere Please consult us when using under the following conditions 1 Environments where hydrogen su...

Страница 10: ...ational time lags The plastic becomes brittle if the switch is exposed to a low temperature low humidity environment for long periods of time Storage for extended periods of time including transportation periods at high temperatures or high humidity levels or in atmospheres with organic gases or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and or it ...

Страница 11: ... force required for operation Appropriate for use with low speed cams and dogs has large stroke Lever available in various shapes to fit operating unit Simulated roller lever Large Medium Small Possible Tip of hinge lever is bent into a semi circle enabling use as a simple roller type Leaf lever Large Large Small Excellent Play in lever is used to assure maximum stroke Construction provides for sp...

Страница 12: ...2019 AECTB16E 1 201903 ...

Страница 13: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Panasonic AV402461 ...

Отзывы: