Chapter 8 System Menu — Maintenance settings
Maintenance settings
Software and hardware version
Version information
Information on the software and hardware versions of this unit can be displayed.
1
Select the <SYS> button
→
[MAINTENANCE]
→
[Status] tab.
2
Check the [System Version] display in the [System Version] column.
f
Check the version of the overall system.
3
Check the display of the following columns.
[Main frame Soft1],
[Main frame Soft2],
[Main frame FPGA]
Check the software and hardware version of Main Frame AV-HS60U1/AV-HS60U2.
[Main Panel Soft],
[Main Panel FPGA],
[Main Panel CPLD]
Check the software and hardware version of of the main control panel.
[Sub Panel1 Soft]*,
[Sub Panel1 FPGA]*,
[Sub Panel1 CPLD]*
Check the software and hardware version of sub control panel 1 (the second Control Panel AV-HS60C1/AV-HS60C2).
[Sub Panel2 Soft]*,
[Sub Panel2 FPGA]*,
[Sub Panel2 CPLD]*
Check the software and hardware version of sub control panel 2 (the third Control Panel AV-HS60C1/AV-HS60C2).
* This function will be available in V2.00.00 or higher.
Updates
Insert the memory card on which the update files are stored into the memory card slot.
For the latest information, visit the following website.
http://pro-av.panasonic.net/ (English only)
1
Select the <SYS> button
→
[MAINTENANCE]
→
[Status] tab.
2
Select an item in [Update File] in the [Update] column.
f
Select the file to be loaded from the file selection screen.
3
Select [OK].
f
Start the update.
Alarm
In this unit, the next alarm message will appear as a popup.
For error displays, the indicator part of [ALARM] in Menu Panel AV-HS60C3 is lit in red.
Alarm message
An alarm message is displayed in Menu Panel AV-HS60C3 when an alarm has occurred.
Alarm message
Type of trouble
Solution
[ALARM! Fan Stop]
Shutdown of the cooling fan
The alarm message disappears if [OK] is selected. Contact
your dealer immediately.
[ALARM! Power Failure]
Power supply problem
[ALARM! Temperature]
Rise in the temperature inside the unit
Alarm status displays
The next hardware alarm can be checked from the <SYS> button
→
[MAINTENANCE]
→
[Alarm] tab page. This page can be displayed even if
[ALARM] of Menu Panel AV-HS60C3 is selected.
1
Select the <SYS> button
→
[MAINTENANCE]
→
[Alarm] tab.
2
Check the display of each item in the [Main frame]/[Main Panel]/[Sub Panel1]/[Sub Panel2] column.
f
The [Sub Panel1]/[Sub Panel2] columns will be available in V2.00.00 or higher.
[Power 1]
Displays the status of problems in the cooling fan or power inside the power supply 1.
[Power 2]
Displays the status of problems in the cooling fan or power inside the power supply 2.
[Fan]
Displays the problem status of the cooling fan. It is displayed in the [Main frame] column.
[Temperature]
Displays the problem status of the internal temperature.
Содержание AV-HS6000
Страница 5: ...Please read this chapter and check the accessories before use Chapter 1 Overview ...
Страница 29: ...This chapter describes basic operations and matters to be performed prior to use Chapter 4 Preparations ...
Страница 45: ...This chapter describes menu operations Chapter 5 Basic Operations ...
Страница 105: ...This chapter describes the input output signal settings Chapter 6 Input Output Signal Settings ...
Страница 116: ...This chapter describes how to operate the CONFIG menu displayed when the CONF button is pressed Chapter 7 CONFIG Menu ...
Страница 125: ...This chapter describes how to operate the system menu displayed when the SYS button is pressed Chapter 8 System Menu ...
Страница 144: ...This chapter describes the terminals and signals of the unit Chapter 9 External Interfaces ...
Страница 149: ...This chapter describes the dimensions and specifications of this product Chapter 10 Specifications ...
Страница 157: ...This chapter describes the setting menu table and terms Chapter 11 Appendix ...
Страница 173: ...Web Site http panasonic net Panasonic Corporation 2014 ...