Turquoise Stroke Switches (ASQ1)
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
AECTB6E 202110
Panasonic Corporation 2021
Note) When switching at high speed or under shock, lever endurance may drop.
Therefore, please be sure to conduct an endurance evaluation under actual switching conditions.
General tolerance: ±0.25
0.4
4.1
3.3
8.4±0.2
5.4±0.15
C0.3
FP Max. 15.7
FP Max. 11.5
RP(N.O.)9.6±0.5 OP(N.O.)9.3±0.5
RP(N.C.)10.1±0.5 OP(N.C.)9.8±0.5
TTP(6.2)
TTP(10.4)
RP
(N.O.)
13.8±0.5
OP
(N.O.)
13.5±0.5
RP(N.C.)14.3±0.5 OP(N.C.)14.0±0.5
(18
°)
14.0
φ1.9
0.5
5.4
2.7
13.3±0.15
8.3±0.1
1.2
2.0
4.53±0.15
4.53±0.15
0.4
1.5
3.2±0.1
4.2
3.7
5.9
5.1
1.2
φ3.0
+0
-0.1
3.0
+0.1 -0
3.0
+0.3 -0.2
CAD
External dimensions
Terminal type: Leaf lever
Operating Force (OF) Max.
1.7 N
Total travel Force (TF) Max.
(reference value)
(3.1 N)
Free Position
(FP) Max.
From mounting boss
and hole center line
11.5 mm
From standoff
15.7 mm
Operating
Position on N.C.
side (OP (N.C.) )
From mounting boss
and hole center line
9.8±0.5 mm
From standoff
14.0±0.5 mm
Operating
Position on N.O.
side (OP (N.O.) )
From mounting boss
and hole center line
9.3±0.5 mm
From standoff
13.5±0.5 mm
Release Position
on N.C. side
(RP (N.C.) )
From mounting boss
and hole center line
10.1±0.5 mm
From standoff
14.3±0.5 mm
Release Position
on N.O. side
(RP (N.O.) )
From mounting boss
and hole center line
9. 6±0.5 mm
From standoff
13.8±0.5 mm
Over travel on N.C. side (OT (N.C.) ) Min.
3.1 mm
Over travel on N.O. side (OT (N.O.) ) Min.
2.6 mm
Total Travel
Position (TTP)
(reference value)
From mounting boss
and hole center line
(6.2 mm)
From standoff
(10.4 mm)
ー 6 ー