– 52 –
Lamp Displays Inside the Viewfinder
Setting the ! Lamp Display
Items subject to ! lamp display are selected at the ! LED page of the setting menu. (When
shipped from the factory, the unit is set so that the ! LED page is not displayed.) To operate the
! LED page, switch the unit to engineer mode or select the ! LED page at the MENU SELECT
page.
¡
See “Setting Menu Configuration” (page 47) for engineer mode and selection of displayed
pages.
1
Set the MENU SET/OFF switch to SET.
The setting status displays disappear from the viewfinder screen, and the page on which
the previous setting menu operations were completed appears. (When the menu is used for
the first time, the first page appears.)
2
Press the PAGE button until the ! LED page shown below appears. (This operation can also
be performed using the PAGE
o
UP/DOWN buttons.)
|
Note
{
E
: ON
. : OFF
¢E
GAIN (0 dB):
This selects whether or not the ! lamp lights when the gain is set to
any value other than 0 dB.
¢
.GAIN (
∂
3 dB):
This selects whether or not the ! lamp lights when the gain is set to
any value other than
p
3 dB.
¢
E
SHUTTER:
This selects whether or not the ! lamp lights when the SHUTTER
switch is set to ON.
¢
.WHITE PRESET:
This selects whether or not the ! lamp lights when the white balance
memory channel is PRST.
¢
E
EXTENDER:
This selects whether or not the ! lamp lights when the lens is in EX-
TENDER mode.
¢
E
FILTER:
This selects whether or not the ! lamp lights when the filter is set to
any value other than 3200K.
3
Repeatedly press the SHIFT/ITEM button to move the cursor to the position of the desired
item.
4
Press the UP and DOWN buttons to choose ! lamp lighted/not lighted for the selected item.
To select ON: Press the UP button. An asterix (
E
) appears to the left of the item name.
To select OFF: Press the DOWN button. A period (.) appears to the left of the item name.
Repeat steps 3 and 4 to continue making ON/OFF settings for other items.
5
When menu operations have been completed, set the MENU SET/OFF switch to OFF.
The setting menu disappears from the viewfinder screen and the displays indicating the
unit’s current status appear at the top and bottom of the viewfinder screen.
-
! L ED -
¢
E
GA I N ( 0 d B )
d B )
. GA I N (
E
SHUT T ER
. WH I TE PRESET
E
EX T ENDER
. F I L TER
- 3