164
Setup: Item Settings
041
LOOP REC
0000
0001
OFF
ON
Specifies whether or not to make loop recording.
➝
For details, refer to “LOOP REC Function” (page 39).
0: Does not make loop recording
1: Makes loop recording
NOTE:
Turning the power off cancels this setting. The unit will then start up using the default
value (OFF) next time it is powered up.
050
P.ON GUI
0000
0001
0002
OFF
THUMB
PLYLST
Specifies whether or not the thumbnail screen or playlist screen appears when the power
is turned on.
0: Does not display thumbnail screen and playlist screen.
1: Displays the thumbnail screen.
2: Displays the playlist screen.
051
GUI OUTPUT
0000
0001
0002
LCD
LCD&V
ALL
Specifies whether the GUI screen will be output to VIDEO OUT or SDI OUT connector.
0: Not output (displayed only on LCD monitor)
1: Output to VIDEO OUT connector
2: Output to both VIDEO OUT and SDI OUT connectors
NOTE:
• When 23.98 or 59-23 is selected in setup menu No. 25 (SYSTEM FREQ), the refresh
of the GUI screen output to SDI OUT may seem unnatural. Also, when the GUI screen
switches to the video screen (and vice versa), the output signal may be distorted.
• Some characters on the GUI screen output to VIDEO OUT may not be clear.
069
CLOCK SET
Sets the internal clock.
NOTE:
Press the STOP or SET button to open the subscreen for setting the time. Change the
date in the subscreen and press the SET button to set the clock date. To exit the
subscreen without setting a date, press the STOP or EXIT button again.
Subscreen
00
YEAR
0000
|
0037
2000
|
2037
Sets the year.
01
MONTH
0001
|
0012
JAN
|
DEC
Sets the month.
NOTE:
Setting a nonexistent day for February, April, June, September and November will
automatically set the equivalent day in the following month.
02
DAY
0001
|
0031
1
|
31
Sets the day.
NOTE:
Setting a nonexistent day for February, April, June, September and November will
automatically set the first day in the following month.
03
HOUR
0000
|
0023
0
|
23
Sets the hour.
Set the hour according to the 24-hour clock.
04
MINUTE
0000
|
0059
0
|
59
Sets the minute.
05
TIME ZONE
0000
0001
|
0018
|
0027
|
0050
00:00
+00:30
|
+09:00
|
–12:00
|
–00:30
Sets the time difference from the world standard time. Use the table below for reference
in setting the time.
Item
Setting
Settings and brief function description
FR
No.
SUPER
DISP.
FR
No.
SUPER
DISP.
59.94Hz
50Hz
23.98Hz
29.97Hz
59-23Hz
25Hz
60-25Hz
only