background image

Panasonic Corporation Electromechanical Control Business Division

industrial.panasonic.com/ac/e/

Technical Terminology & Cautions for Use (Detection Switches)

Panasonic Corporation 2021

AECTB36E   202110

MOUNTING STATE AND ENVIRONMENT

Checking the insulation distance

After mounting and wiring, check the insulation distance between 
terminals and the ground. If the insulation distance is inadequate, 
mount insulating material between as required.

Fastening the snap-action switch body

See the Section “CAUTIONS FOR USE” for the individual switch.

Position adjustment with effector

1)  The effector should be positioned so that direct force is not applied 

to the plunger or actuator in its free position. The operating force to 

the plunger should only be applied in a perpendicular direction.

2)  Note that the use of the switch as a stopper may cause an 

operational problem.

Switch installation position

 Basically, the switch should be installed so that the object to 

press 

the switch’s plunger or lever can press it down to 70 to 100% of OT 

of the switch. When determining the position, the tolerance of OP 
(Operating Position) and other factors should be taken into account.
The following describes the case where the strictest tolerance 
conditions are adopted.

 Example: Hinge lever type FS switch

 

Reference values:  OP = 8.8±0.8 mm

 

PT = Max. 2.8 mm

 

OT = Min. 1.2 mm

FP

OP

PT

TTP

OT

(1)  When the switch is not pressed 

The object to press the lever should not be in contact with the 
lever. 
For this purpose, the object should be at a distance from the 
switch father than the maximum FP (Free Position) value. 

FP Max = OP Max + PT Max = 9.6 + 2.8 = 12.4 mm Max

 

The object should be at a distance of 12.4 mm or more

 

from the mounting hole.

(2)  Depressed position

 

The plunger/lever should be pressed down to 70% or more of 

OT (Over Travel). Therefore, the depressed position should be 
calculated based on the minimum value of OP (Operating 

Position) and the 70 and 100% of the OT value.

 

OP Min - 70% of OT = 8.0 - 0.84 = 7.16 mm

 

OP Min - 100% of OT = 8.0 - 1.2 = 6.80 mm

 

The plunger/lever should be pressed down to the position of 

6.80 to 7.16 mm from the mounting hole.

Soldering precautions

For manual soldering, lay the terminals flat (horizontal with the 
ground) and quickly perform the soldering operation using a 
soldering iron with the appropriate heat capacity and the proper 
amount of solder. Take care that the flux does not flow into the 
switch interior by using a ventilation fan to discharge flux gas and to 
prevent contact of the switch body with the soldering iron tip.
Be careful not to apply force to the lead wires or the terminal 
portions immediately after soldering.
The temperature setting and time conditions vary depending on the 

product.
See the section “CAUTIONS FOR USE” for each product.

<Examples>

Soldering iron tip

Wrong

Correct

Avoid using in a silicon atmosphere

Avoid using organic silicon rubber, adhesives, sealing compounds, 
oil, grease, and wires in a silicon atmosphere.

 Please consult us when using under the following 

conditions*:

1)  Environments where hydrogen sulfide or other corrosive gases are 

present.

2)  Environments where gasoline, thinner or other flammable, explosive 

gases are present.

3)  Dusty environments (for non-seal type snap action switches).

4)  The perpendicular operating speed exceeds the allowable operating 

speed.

5)  Switching between different poles.
6)  Use in environments not in the prescribed temperature or humidity 

range.

Storage precautions

To prevent discoloration due to sulfurization of the terminals (silver- 

plated), store the switches in a polyethylene bag or other suitable 

airtight container.

ー 9 ー

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Содержание AHF21

Страница 1: ... point Basic point Output characteristics H O peration angle Operation angle Return angle Return angle Return angle Return angle Output characteristics L Output characteristics L For Ta 25 C and applicable circuit conditions 1 Operation characteristics Operation speed 6 degrees second Operation angle Output VOL VOH 25 to 60 degrees Return angle Output VOH VOL Min 20 degrees 2 Output VO characteris...

Страница 2: ...rt Three times from height of 100 cm High temperature high humidity storage ability Leave for 500 hours at 85 C and 85 RH no condensing High temperature storage ability Leave for 500 hours at 85 C Low temperature storage ability Leave for 500 hours at 25 C no freezing Shock and heat resistance Subject to 100 cycles each consisting of 30 minutes at 25 C and 30 minutes at 85 C Resistance to hydrogen...

Страница 3: ... 1 Terminal No 4 Terminal No 1 LED Anode Terminal No 2 LED Cathode Terminal No 4 Photo transistor Emitter Terminal No 3 Photo transistor Collector 3 1 0 1 11 9 0 1 5 1 0 1 φ1 3 General tolerance 0 4 Terminal No 1 Terminal No 4 Terminal No 2 Terminal No 3 2 6 11 9 11 5 0 7 5 1 0 5 3 1 0 5 0 9 Terminal No 1 LED Anode Terminal No 2 LED Cathode Terminal No 4 Photo transistor Emitter Terminal No 3 Phot...

Страница 4: ...with a sealant for PC boards please make sure to evaluate and confirm that no sealant enters the inside of the unit Preventing a malfunction The TiP sensor uses an internal sphere hence chattering occurs if it is subjected to vibration or shock To prevent chattering continuously read pulses of 30 ms max using a microprocessor and set the microprocessor so that the switch goes L ON or H OFF if the ...

Страница 5: ... to the contact and switching operations are performed The life test is performed at a switching frequency of 20 times minute and operating speed of 100 mm second at the regular cam Contact form This refers to the components determining the type of application which make up the electrical input output circuits in the contact SPDT SPST N C SPST N O Insulation resistance Resistance between non conti...

Страница 6: ... Pretravel PT mm degree Max Distance or agree of the actuator movement from free position to operating position Overtravel OT mm degree Min The distance or degree which the actuator is permitted to travel after actuation without any damage to the switching mechanism Movement Differential MD mm degree Max The distance or degree from operating position to release position of the actuator Totaltravel...

Страница 7: ... to contacts or contact response failure Driving Mechanism Use of a driving mechanism which will cause physical impact to the actuator should be avoided Example Bad Good TECHNICAL NOTES ON ELECTRICAL CHARACTERISTICS 1 The snap action switch is designed for AC operations While it has small contact gaps and no arc absorber it may be used for low capacity DC operations Please refer to the rating of e...

Страница 8: ...itch 1 For DC circuits only ZNR Varistor Contact for snap action switch Induction load Can be used for both AC and DC 2 Do not connect the contacts on individual switches to different type or different poles of the power supply Examples of power supply connections connection to different poles PL Wrong Solenoid load Lamp load PL Right Solenoid load Load connected to same pole Lamp load Example of ...

Страница 9: ... depressed position should be calculated based on the minimum value of OP Operating Position and the 70 and 100 of the OT value OP Min 70 of OT 8 0 0 84 7 16 mm OP Min 100 of OT 8 0 1 2 6 80 mm The plunger lever should be pressed down to the position of 6 80 to 7 16 mm from the mounting hole Soldering precautions For manual soldering lay the terminals flat horizontal with the ground and quickly pe...

Страница 10: ...eeze on the switch when the temperatures is lower than 0 C 32 F This causes problems such as sticking of movable parts or operational time lags The plastic becomes brittle if the switch is exposed to a low temperature low humidity environment for long periods of time Storage for extended periods of time including transportation periods at high temperatures or high humidity levels or in atmospheres...

Страница 11: ...large stroke Lever available in various shapes to fit operating unit Simulated roller lever Large Medium Small Possible Tip of hinge lever is bent into a semi circle enabling use as a simple roller type Leaf lever Large Large Small Excellent Play in lever is used to assure maximum stroke Construction provides for space where lever is attached for outstanding resistance to freezing Hinge roller lev...

Страница 12: ...ka 571 8506 Japan Panasonic Corporation 2021 AECTB18E 202110 Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com ...

Отзывы: