Two-wire output type
■
Precaution when using LED-equipped reed switch
When a LED is connected in series to an input contact such as LED-equipped reed switch,
make sure that the voltage applied to the GM1 input terminal is greater than the ON voltage. In
particular, take care when connecting a number of switches in series.
■
Precaution when using two-wire type sensor
If the input to the GM1 does not turn OFF because of leakage current from the two-wire type
photoelectric sensor or proximity sensor, connect a bleeder resistor as shown below.
■
Precaution when using LED-equipped limit switch
If the input to the GM1 does not turn OFF because of leakage current from the LED-equipped
limit switch, connect a bleeder resistor as shown on below.
5.3.3 High-speed Counter Input Wiring
● For the connection between the count input (phases A, B, Z) and encoder, etc., use
shielded twisted-pair cables.
● The length of connected wires should be 10 m or below.
5.3 Wiring of Input and Output
5-8
WUME-GM1H-02
Содержание AGM1CSEC16P
Страница 1: ...Motion Controller GM1 Series Reference Manual Hardware WUME GM1H 02 2021 8 ...
Страница 2: ... MEMO 2 WUME GM1H 02 ...
Страница 4: ... MEMO iv WUME GM1H 02 ...
Страница 8: ... MEMO viii WUME GM1H 02 ...
Страница 9: ...1 Before Using This Product 1 1 Safety Precautions 1 2 1 2 Handling Precautions 1 3 WUME GM1H 02 1 1 ...
Страница 12: ... MEMO 1 4 WUME GM1H 02 ...
Страница 16: ... Make sure to connect an end unit to the end of the system 2 1 Basic System Configuration 2 4 WUME GM1H 02 ...
Страница 39: ...3 2 Expansion Units WUME GM1H 02 3 19 ...
Страница 40: ... MEMO 3 20 WUME GM1H 02 ...
Страница 70: ... MEMO 6 6 WUME GM1H 02 ...
Страница 75: ...8 Device Reset 8 1 Device Reset by GM1 Controller Operation 8 2 WUME GM1H 02 8 1 ...
Страница 84: ... MEMO 9 8 WUME GM1H 02 ...
Страница 85: ...10 Maintenance and Inspection 10 1 Inspection 10 2 WUME GM1H 02 10 1 ...
Страница 115: ...Unit mm 11 6 2 Dimensions of the GM1 Expansion Unit Digital I O unit 11 6 Dimensions WUME GM1H 02 11 29 ...
Страница 116: ...Unit mm Analog I O Unit Applicable model AGM1AD8 and AGM1DA4 Unit mm 11 6 Dimensions 11 30 WUME GM1H 02 ...
Страница 117: ...Pulse Output Unit Unit mm 11 6 Dimensions WUME GM1H 02 11 31 ...
Страница 118: ... MEMO 11 32 WUME GM1H 02 ...
Страница 122: ... MEMO App 4 WUME GM1H 02 ...
Страница 124: ... MEMO WUME GM1H 02 ...
Страница 125: ... MEMO WUME GM1H 02 ...
Страница 126: ...Panasonic Corporation 2021 August 2021 WUME GM1H 02 ...