1
Chapter
Maintenance
and
Inspections
Priority
Warning
type
LCD indication
Tally lamp
WARNING
lamp
Alarm
tone
Warning description
and recording/playback
operation
Countermeasures
7
Error of
camera
section
WARNING cause
indication
*
4
blinks red
Off
Off
No
An error in the camera section
is detected. Operation
continues, but abnormal
shooting may occur.
Check the cause
indication
*
4
and
consult your
distributor.
8
P2 card fully
recorded
P2
FULL
Blinks red
Blinks 4
times per
second after
completion
of recording.
Lights after
completing
recording
Continuous
tone after
completing
recording
No more space on P2
cards left for recording.Stop
recording.
*
5
Delete clips that are
no longer needed or
insert a new card.
9
Playback
sync error
SYNC POSI FAILED
Blinks white
Off
Off
No
The synchronization of clip
position has failed. It may
occur when the reference
signal is unstable during 3D
clip playback
Check the number
and type of the
clip. Or press the
STOP button to stop
playback, check the
connection and/or
the input signal, then
restart playback.
10
Recording
error
REC WARNING
Cause indication
*
6
Blinks red
Blinks 4
times per
second
Blinks 4
times per
second
Intermittent
tone 4
times per
second
A recording error has
occurred. The error may
terminate recording.
*
7
Turn the power off
and then back on
again and check
recording and
playback. Replace
any P2 card that
does not enable
normal recording.
(Continued on the next page)
*
4
Camera WARINNG cause indication
• FOCUS NG
: Focus error (
: L, R or L/R)
• ZOOM NG
: Zoom error (
: L, R or L/R)
• IRIS NG
: Iris error (
: L, R or L/R)
• ND FILTER NG
: ND filter error (
: L, R or L/R)
• CONV. NG
: Convergence error (
: L, R or L/R)
• SUB LENS NG
: Sub-lens error (
: L, R or L/R)
*
5
Perform either of the following procedures to cancel this warning.
• Press a playback control button.
• Press the THUMBNAIL button.
• Remove the P2 card and insert another card.
*
6
REC WARNING cause indication
• CARD ERROR
: P2CARD error (
indicates the slot of the card with the error.) Stops recording.
• REC RAM OVERFLOW: Overflow of recording RAM. Stops recording.
• PULL DOWN ERROR: 24P, 30P (25P) video pulldown error. Recording continues.
• OVER MAX# CLIPS: Recording is interrupted as the limit for the number of clips that can be recorded to one P2 card
has been reached.
• IRREGULAR FRM SIG: The reference signal, such as the GENLOCK input, is distorted.
• L/R DURATION NG: The duration of the recorded clip is different between the L and R P2 cards.
*
7
Perform either of the following procedures to cancel this warning.
• Press the REC button.
• Press a playback control button.
• Press the THUMBNAIL button.
• Remove all cards.