1.
Install the remote controller mounting plate to the wall with the two accessory screws
4
.
2.
Fasten the screws properly until screw head is lower than the rib and reach the base of remote controller
mounting plate to ensure they do not damage the PCB inside the remote controller
1
.
3.
The feeding-out direction for the remote controller cable can be either via top, left or right side.
4.
Use nipper to cut a notch at the upper case. (Select the intended feeding-out position)
5.
Route the remote controller cable
2
inside the mounting plate in accordance with the intended feeding-out
direction. (Refer to the illustration at below)
6.
Insert fi rmly the connector of remote controller cable
2
to connector (CON1) in the upper case circuit board.
(Refer to the illustration at below)
7.
Secure the remote controller upper case to the mounting plate with the tabs provided.
1.
Open the indoor control box cover by removing two pieces of screws.
2.
Remove the plugs at the side of the control box and fi x the conduit connectors to knockout holes with lock nuts.
Knockout holes
Connectors
Lock Nuts
Control Box
Plugs
Screws
Control Box cover
3.
Guide the remote controller cable
2
into the unit through the upper knockout hole and secure the cable to the
holder.
4.
Firmly connect the connector of remote controller cable
2
to indoor unit PCB connector.
5.
Guide the remote controller cable
2
earth wire into the control box through the upper knockout hole.
6.
Fix the earth wire with a screw to the grounding location provided in the control box.
Earth wire (remote controller cable)
Indoor/outdoor connection cable inlet
Fix remote controller cable connector
Remote controller cable
2
Fix remote controller cable
to the holder
7.
Install back the control box cover. Be careful not to clamp the cable in between control box and control box cover.
Control box cover
Indoor unit
Control box
Remote controller
1
Wall
Upper case
Upper tab
Mounting plate
Screws
4
Lower tab
Remote controller cable
2
Connector (CON1)
3. CONNECTING THE REMOTE CONTROLLER CABLE TO INDOOR UNIT
Upper case
Gaps
ACXF60-03410
1.
R e m o v e t h e r e m o t e c o n t r o l l e r
1
m o u n t i n g p l a t e .
(Insert a fl at-tipped screw driver or similar tool 3/32" to 1/8" (2 to
3 mm) into one of the gaps at the bottom of the case, and twist
to open. Refer to the illustration at right.)
Be careful not to damage the mounting plate.
2.
Do not remove the protective tape which is affi xed to the
upper case circuit board when removing the remote controller
mounting plate.
3.
Secure the mounting plate to an outlet box or wall. Refer to (A)
or (B) instructions below depending on your choice of cable
installation.
4.
Be sure to use only the screws provided.
5.
Do not over tighten the screws, as it may result in damage to
the mounting plate.
2. INSTALLING THE REMOTE CONTROLLER UNIT TO THE WALL
Screw
driver
Screw
3
or
Screw
4
1.
Embed an outlet box into the wall. Outlet box may be purchased separately. Medium-sized square outlet box
(obtain locally) Part No. DS3744 (Panasonic Corporation) or equivalent.
2.
Secure the remote controller mounting plate to the outlet box with the two accessory screws
3
.
Make sure that the mounting plate is fl at against the wall at this time, with no bending.
3.
Pass the remote controller cable
2
into the box.
4.
Route the remote controller cable
2
inside the mounting plate through rear feeding-out direction.
5.
Insert fi rmly the connector of remote controller cable
2
to connector (CON1) in the upper case circuit board.
[Refer to the illustration at below.]
6.
Secure the remote controller upper case to the mounting plate with the tabs provided.
Wall
Upper case
Mounting plate
Upper tab
Connector (CON1)
Screw
3
Lower tab
Outlet box
B. IF REMOTE CONTROLLER CABLE IS EXPOSED
Rib
Screws
4
Wall
Remote controller
mounting plate
SAFETY PRECAUTIONS
•
Read the following “SAFETY PRECAUTIONS” carefully before installation.
•
Electrical work must be installed by a licensed electrician.
•
The caution items stated here must be followed because these important contents are related to safety. The meaning
of each indication used is as below.
Incorrect installation due to the non-observance of the instructions will cause harm or damage, and the seriousness is
classified by the following indications.
•
Perform a functional test to confi rm that no abnormality occurs after the installation. Then, explain the operation,
care and maintenance to user as stated in instructions. Please remind the customer to keep the operating
instructions and installation instruction for future reference.
A. IF REMOTE CONTROLLER CABLE IS EMBEDDED
•
Allow suffi cient space around the remote controller
1
as shown in the illustration above.
•
Install in a place which is away from direct sunlight and high humidity.
•
Install on a fl at surface to avoid warping of the remote controller. If installed to a wall with an uneven surface,
damage to the LCD case or operation problems may result.
•
Install in a place where the LCD can be easily seen for operation. (Standard height from the fl oor is 3.9ft to 4.9ft
(1.2 to 1.5 meters.))
•
Avoid installing the remote controller cable near refrigerant pipes or drain pipes, otherwise it will cause electrical
shock or fi re.
1. SELECTING THE INSTALLATION LOCATION
Remote
controller
cable
2
Rear feeding-out
position
Mounting plate
Connector
(CON1)
Upper case
Tabs
Upper case
Mounting plate
Remote
controller
mounting
plate
1 3/16"
(
30mm)
or more
1 3/16"
(
30mm)
or more
1 3/16"
(
30mm)
or more
4 23/32"
(
120mm)
or more
Upper case
Mounting plate
Remote controller
1
ATTACHED ACCESSORIES
Mounting plate
Remote
controller
cable
2
WARNING
This indication shows the possibility of causing death or serious injury.
CAUTION
This indication shows the possibility of causing injury or damage to properties only.
The items to be followed are classified by the symbols:
Symbol with white background denotes item that is PROHIBITED from doing.
Symbol with dark background denotes item that must be carried out.
Wired Remote Controller Installation Manual
WARNING
Do not modify the length of the remote controller cable. Otherwise, it will cause fire or electrical shock.
Be sure to turn off the main power before installing and connecting the remote controller. Otherwise, it will
cause electrical shock.
Engage an authorized dealer or specialist for installation. If installation done by the user is defective, it will
cause electrical shock or fire.
Install strictly according to these installation instructions. If installation is defective, it will cause electrical shock
or fire.
Use specified accessories and parts for installation. Otherwise, it will cause the set to fall, fire or electrical
shock.
For electrical work, follow the local national wiring standards and regulations, and these installation
instructions. Otherwise, it will cause electrical shock or fire.
Wire routing must be properly arranged so that control board cover is affixed properly. If control board cover is
not affixed perfectly, it will cause fire or electrical shock.
If passing the remote controller cable through a wall, be sure to install a water trap above the cable.
Otherwise, it will cause electrical shock.
CAUTION
Do not touch the sharp aluminium fin of air conditioner unit during wired remote controller installation, sharp
parts may cause injury.
Install on a flat surface to avoid warping of remote controller, or else damage to the LCD case or operation
problems may result.
Avoid installing the remote controller cable near refrigerant pipes or drain pipes, otherwise it will cause
electrical shock or fire.
Install the remote controller cable at least 1 31/32"(5cm) away from electric wires of other appliances to avoid
misoperation (electromagnetic noise).
Be sure to use only the accessory screws to avoid damage of remote controller PCB.
No.
Name
Qty
Diagram
Remark
1
Remote controller
1
2
Remote controller cable
1
Length 32.8ft (10m)
3
Screw
(M4 machine pitched - 1 3/16"
30mm))
3
Installing the remote controller to an outlet box
(embedded cable)
4
Screw
(M4 self tapping - 9/16"(14mm))
3
Installing the remote controller to the wall
(exposed cable)
CAUTION
When the wall is hollow, please be sure to use
the sleeve for remote controller cable to prevent
dangers caused by mice biting the cable.
CAUTION
Be sure to turn off the main power before installing and connecting the remote controller.
Otherwise, it will cause electrical shock.
Upper case
Mounting plate
Right
feeding-out
Mounting plate
Connector
(CON1)
Upper case
Notches
Remote
controller
cable
2
Tabs
Left feeding-out
position
Top feeding-out
position
Remote controller
1
ACXF60-03410
ENGLISH
1
2