![background image](http://html1.mh-extra.com/html/panametrics/ctf878/ctf878_startup-manual_3401710048.webp)
Model CTF878 Startup Guide
40
WARNING
DISCONNECT POWER BEFORE
REMOVING FUSE.
SLOT6
SLOT5
SLOT4
SLOT3
SLOT2
SLOT1
CONNECTION DIAGRAM
ALARMS
RTN
SIG
D
C
SIG
RTN
B
SIG
RTN
A
SIG
RTN
ANALOG IN
INHI
A
INLO
INHI
+24V
RTN
+24V
B
INLO
RTN
C
A
B
C
NO
D
TOTL/FREQ
C
NO
NO
C
NO
C
COM
COM
+
COM
+
COM
C
B
RTD IN
G N L
100-240 VAC
FUSE
1 AMP
RS232
C
T
S R
D
T
R
X
T
X
N
R
T
TB1
5
1
UP
TX1
RX1
X
D
C
R
S
STREAM
RX2
TX2
STREAM
DN
ANALOG OUT
1
1
1
1
8
8
8
8
1
4
1 RCV
3 TWIND
5 RWIND
7 GATE
9 ARTN
11 RI_PK
13 R1_I
15 R1_Q
2 ARTN
4 –
6 DRTN
8 DRTN
10 ARTN
12 R2_PK
14 R2_I
16 R2_Q
2
P1 1
16
15
DIRECT RTD INPUTS
1
Input A - SIG(+)
Input A - Common (C)
2
3
N/C
4
5
6
7
8
Description
Pin #
Input A - Common (C)
Input B - Common (C)
Input B - SIG(+)
N/C
Input B - Common (C)
TOTALIZER/FREQUENCY OUTPUTS
Output A - Common (C)
Output A - Normally Open (NO)
1
2
Description
8
5
4
3
6
7
Pin #
Output B - Common (C)
Output B - Normally Open (NO)
Output C - Common (C)
Output C - Normally Open (NO)
Output D - Common (C)
Output D - Normally Open (NO)
4-20 mA ANALOG INPUTS
Input B - +24V
1
2
3
4
5
6
7
8
Pin #
Description
Input B - INHI
Input B - INLO
Input B - RTN
Input A - +24V
Input A - INHI
Input A - INLO
Input A - RTN
4-20 mA ANALOG OUTPUTS
1
2
8
5
4
3
6
7
Pin #
Description
Output A - RTN(–)
Output A - SIG(+)
Output B - RTN(–)
Output B - SIG(+)
Output C - SIG(+)
Output C - RTN(–)
Output D - SIG(+)
Output D - RTN(–)
Relay A - Normally Open (NO)
1
2
8
5
4
3
6
7
9
Pin #
ALARM RELAYS
Description
Relay A - Common (C)
Relay A - Normally Closed (NC)
Relay B - Normally Open (NO)
Relay B - Common (C)
Relay B - Normally Closed (NC)
Relay C - Normally Open (NO)
Relay C - Common (C)
Relay C - Normally Closed (NC)
4-20 mA ANALOG OUTPUTS
Description
Pin #
Output 1 - SIG
1
Output 2 - RTN
4
2
Output 1 - RTN
3
Output 2 - SIG
For compliance with the European Union's Low Voltage Directive
(73/23/EEC), this unit requires an external power disconnect device
such as a switch or circuit breaker. The disconnect device must be
marked as such, clearly visible, directly accessible, and located within
1.8 m (6 ft) of the CTF878.
For compliance with the European Union's Low Voltage Directive
(73/23/EEC), a transparent plastic shroud is required to protect the
electrical connections. The shroud must remain in place, except
while the unit is being wired, and reinstalled after the wiring has
been completed.
RTN - Digital Return
1
3
2
5
4
Description
RS232 SERIAL PORT
Pin #
TX - Transmit
RX - Receive
DTR - Data Terminal Ready
CTS - Clear To Send
Ground
Line Power/Neutral
Description
Pin #
L2/N
G
POWER INPUT
External Ground
Connection
For CE compliance, the enclosure must
be grounded. The grounding point is
any one of the four mounting holes.
1
9
A
B
C
C
C
NO
NC
NO
NO
NC
C
NC
Downstream Receive Transducer
Upstream Receive Transducer
Downstream Transmit Transducer
Upstream Transmit Transducer
L1 L2/ N
Plastic LVD Shroud
One option card of each available
type is shown in this diagram. These
cards are not always installed in the
same slots used for this example.
Line Power
L1
G
Fi
gu
re
2
5:
C
TF
87
8
El
ec
tr
on
ic
s
C
on
so
le
W
iri
ng
(r
ef
. d
w
g
#
70
2-
50
8)
Содержание CTF878
Страница 1: ...panametrics com Flow 910 254U Rev A AUG 2021 Model CTF878 Clamp On Tag Flowmeter Startup Guide...
Страница 2: ......
Страница 4: ...ii no content intended for this page...
Страница 6: ...Warranty iv Model CTF878 Startup Guide no content intended for this page...
Страница 8: ...Contents vi Model CTF878 Startup Guide...
Страница 76: ...Model CTF878 Startup Guide 68...
Страница 96: ...Appendix A 88 Model CTF878 Startup Guide...
Страница 99: ...Model CTF878 Startup Guide 91 Appendix B 9 21 10 22 11 23 12 24...
Страница 100: ...Appendix B 92 Model CTF878 Startup Guide...
Страница 104: ...Index 96 Doc Tittle Manual Type...
Страница 106: ......
Страница 107: ......