800-472-5555 • www.panamax.com • www.furmansound.com
By
Panamax
~
Furman
INSTALLATION INSTRUCTIONS
MAX IN-WALL
™
SINGLE GANG SURGE PROTECTION
Features:
• Fits most standard single-gang plastic or metal box.
• Uses standard wiring device screw-hole.
• Mounting Yoke.
Designed to mount to any standard outlet box.
• Decora Faceplate Interface.
This piece surrounds the receptacles and fits within
a standard cover plates Decora cutout.
• Bi-color Indicator LED.
Green = Power On
Red = Line Fault
• Mounting Screws. Two (2) 6-32 x .75” pan head
screws are pre-installed, with retention features,
to mount the unit to an outlet box.
• Both Outlets with Protect-or Disconnect Circuitry.
MIW-SURGE-1G
INS00885-A
Caution, Before You Begin:
To avoid electrical shock or serious injury turn OFF all
power leading to your installation of MIW-SURGE-1G such as circuit breaker or switch.
3 Wire nuts
included
Mounting:
1.
Wire nuts (included) are used to connect the three 6 inch
MIW-SURGE-1G wires. Connect the
black (HOT)
wire to the
black
wire from the wall outlet,
white (NEUTRAL)
to
white
and the
green (GROUND)
wire to the (typically bare)
ground wire.
2.
The MIW-SURGE-1G is then installed in the outlet box just like any duplex
receptacle or switch by driving the pre-attached screws into the outlet box.
3.
Outlet box compatibility. This product is designed
to fit into most standard metal or plastic outlet boxes.
Black =
AC Hot
White =
Neutral
Green =
Ground