Mi User Manual 

Mi User Manual 

MAN-066-0001 

Issue A 

Date  01/02/08 

Written by JP

 

Содержание MicroCALL+

Страница 1: ...ouse Llantarnam Park Way Cwmbran NP44 3AW United Kingdom Tel 44 0 1633 489479 Fax 44 0 1633 877857 Email info palmer co uk Web www palmer co uk MicroCALL User Manual MicroCALL User Manual MAN 066 0001...

Страница 2: ...exibility Efficiency Simplicity Contents Page 2 Introduction Page 3 Principle Of Correlation Page 4 Battery Installation And Charging Page 5 Switching On The Basestation Page 6 Outstation Deployment P...

Страница 3: ...ion unit in listening mode to hear the leak noise detected by the Outstations A database of filter options and presets are also available within the unit to increase accuracy when being used in areas...

Страница 4: ...n as a pressure wave The leak noise travels at a constant velocity V which depends on the material and diameter of the pipe and arrives first at the sensor nearer the leak The arrival time at each sen...

Страница 5: ...ly using the supplied Chargers Only bat teries with the correct specification and type must be used These are available from Palmer Environmental should replacements be required All batteries are iden...

Страница 6: ...ction by pressing the assigned key Press key 1 to enter the Correlate screen Press key 2 to select Correlation Mode two or three station correlation Press key 3 to enter the Correlation Setup screen P...

Страница 7: ...sor has a strong magnet that will enable it to remain in position on steel iron fittings Always ensure the contact point is free from dirt so that the magnet makes a good contact We recommend the use...

Страница 8: ...layed on the screen The up down arrows select items within a list and move the cursor on the graph Numbers 0 9 are used to select the required menu or function Enter accepts any changes or saves curre...

Страница 9: ...ns deployed and turned on press the Enter key to start the correlation Correlation can be stopped at any time by pressing the Enter key a second time Press Enter key for Correlation Set up Press Enter...

Страница 10: ...10 Correlation Setup The Stations to be used for Correlation are selectable Flexibility Efficiency Simplicity...

Страница 11: ...tion A more accurate velocity ensures more accurate reporting of the leak position 3 Station requires red blue and yellow optional outstations this can be used in situations where the pipe material is...

Страница 12: ...tside of the sensors called an Out of Bracket check shown below Out of Bracket Leak is outside of Sensors Unlike correlation where the more central the leak is positioned between the sensors the more...

Страница 13: ...be removed and press 1 to select a start point A small arrow will appear below the correlation graph Move the dashed cursor line along the data to select the stop point Press 1 again and the section o...

Страница 14: ...nd to reach the sensor increases proportionally with the distance For example if you move the sensor twice as far away the sound will take twice as long to reach it It is this linear rela tionship tha...

Страница 15: ...ion colour This is the outstation that was not moved during the correlations The control unit will store the material and diameter of the first correlation result and compare with the next result s to...

Страница 16: ...lation Press 1 to add the second correlation result A second cross will appear and a line will pass through both The distance from the static sensor to the leak and the calculated velocity will be sho...

Страница 17: ...to the pipe material database where you can define your own materials also velocities for specific diameters Option 5 system setting sub menu Press key 1 to set up time intervals after which the speci...

Страница 18: ...istening to an Outsatation the transmission will occur in fifteen second blocks This is due to the system using a single radio frequency it then allows listening mode to finish according to the user s...

Страница 19: ...ls and press OK To edit an existing pipe segment select the segment in the table and press the Edit button The Enter Pipe Segment box will be displayed allowing the user to change the segment s settin...

Страница 20: ...20 Settings Pipe Materials Database Enables the user to manually define up to 20 pipe materials for use on the current cor relation...

Страница 21: ...diting of specific information of the current Correlation Press key 2 to show system status battery power radio signal and sensor to unit connection Press key 3 to display current version of Firmware...

Страница 22: ...frequencies of 406Hz and above Quick set non metallic removes all frequencies from 696Hz and above So the sen sors will only listen to frequencies of 695Hz and below Clear all removes any filter sett...

Страница 23: ...off was selected so all frequencies from 0Hz to 257Hz will be removed Press 2 High cut off When the right cursor line is selected the high cut off option is displayed Move the right cursor to the requ...

Страница 24: ...splay VGA TFT LCD Antenna External antenna magmount Mixed material 10 sections Battery level indication For all system units Battery type Rechargeable Lithium ion batteries field replaceable Firmware...

Страница 25: ...tery life 18 hours Antenna External antenna Dimensions 203mm x 136 x 51mm Weight 0 826kg Housing Fully injection moulded ABS Connectors Military specification Amphenol Sensor Type Digital sensor with...