background image

UT319

UT319 Series

service 

instructions

1371632

IMSIUT319

EN

U T 3 1 9   S e r v i c e   I n s t r u c t i o n s

ENGLISH

Содержание UT319 Series

Страница 1: ...UT319 UT319 Series service instructions 1371632 IMSIUT319 EN UT319 Service Instructions ENGLISH ...

Страница 2: ...nd 1042mm 41in for length 40 assemblies 4 2 2 The UT319 Housing is supplied without a filter element For element installation and servicing procedures refer to Section 7 4 3 Threaded pressure gauges or electrical pressure switches when fitted hand tighten plus 1 2 turns with a wrench Threaded differential pressure indicator if fitted must be torque tightened to 30 33 ft lb or 40 45 Nm If no differ...

Страница 3: ...ntinue operating until the signal red light goes out as system warms to normal operating temperature This feature can be used as warm up indication in operating procedures If the warning signal red light remains or appears when system is warm replace the filter element 6 4 Use of both positive indication green light and negative indication red light for dirty element is recommended to effectively ...

Страница 4: ... whatsoever 4 7 Filter element servicing During servicing the external surfaces of the filter assembly must be cleaned to remove any dust deposits Servicing must be conducted using suitable tools that do not present a hazard Servicing must not be carried out when a potentially explosive atmosphere is present Refer to Service Parts List Section 9 for item numbers for applicable replacement element ...

Страница 5: ... Quantity 1 Head Consult factory 1 2 Cover sub assembly Fluorocarbon 1 3 Shroud shell sub assembly 1 4 Indicator options 3 Gauge Pressure switch See product literature Differential pressure indicator 5 O ring cover to head 1 6 O ring isolation cone to head 1 7 O ring head to tank 1 8 Filter element UE319 See product literature 1 ...

Страница 6: ...UT319 UT319 Series RETURN LINE IN TANK FILTERS s e r v i c e instructions 6 2 6 8 3 1 Figure 2 4 5 7 ...

Страница 7: ...s AA 4 trous taraudés de profondeur AA 4 fori completamente filettati profondità AA 4 tapgaten met draad over volle diepte 4st fästhål Gänga Z Min gängdjup AA GG Q Flange Connection Details Flange Code Nominal Tube Size GG Q Z Thread AA D24 11 2 1 406 2 750 1 2 13 UNC 1 F24 11 2 35 7 mm 69 8 mm M12 x 1 75 25 mm D32 2 1 688 3 062 1 2 13 UNC 1 F32 2 42 9 mm 77 8 mm M12 x 1 75 25 mm D40 21 2 2 000 3 ...

Страница 8: ...he web at www pall com Pall Corporation has offices and plants throughout the world in locations including Argentina Australia Austria Belgium Brazil Canada China France Germany Hong Kong India Indonesia Ireland Italy Japan Korea Malaysia Mexico the Netherlands New Zealand Norway Poland Puerto Rico Russia Singapore South Africa Spain Sweden Switzerland Taiwan Thailand United Arab Emirates United K...