2. SAFETY GUIDELINES

 

(cont’d)

 

 

 

NEVER operate this generator unless all original guards, shields, covers, etc. are undamaged and in 
good working condition. Operating this generator with damaged or inoperable guards, shields, 
covers, etc. could result in damage to the generator, fire, electrocution, injury or death. 

 

 

    

RISK OF CARBON MONOXIDE POISONING 

Operate and fuel equipment in well ventilated areas free from obstructions. Engine exhaust contains 
carbon monoxide, an odorless, colorless, deadly poison. Exposure to Carbon Monoxide can cause 
headaches, nausea, severe sickness or death. 

 

   

RISK OF EXPLOSION OR FIRE

  

Spilled gasoline and its vapors can become ignited from cigarette sparks, electrical arcing, exhaust 
gases, and hot engine components such as the muffler. Never refuel the engine while hot or running. 
Move unit away from refueling area before starting engine. Equip areas with fire extinguishers 
suitable for gasoline fires. 

 

Heat will expand gas vapours in the tank, which could result in spillage possibly causing a fire or an 
explosion.  

 

Lubricating oil conforming to the engine manufacturer’s specifications must be added to the proper 
level before operation. Failure to fill the crankcase with lubricating oil will void all engine warranties.

 

 

 

Do not

 

exceed the rated capacity of the generator. The total electrical loads at each outlet must be 

added to determine the total electrical load. The total load must not exceed the rated capacity of the 
generator. If the driven apparatus does not list wattage, but only amperage, wattage may be 
determined by multiplying amperage  by voltage (watts = amps x volts). 

 

 

Do not

 

tamper with the engine-governed speed. the generator operates at a nominal speed of 3600 

rpm. Increases in speed over the nominal 3600 rpm will increase the chance of personal injury due to 
rotational stresses on the rotating members. Operation of the generator at speeds below the nominal 
3600 rpm could cause damage to the generator or driven apparatus due to low voltage output. 

 

Do not modify or misapply the generator set in any way. Operation of the generator other than 
intended, could result in generator set damage, bodily injury or even death from electrocution. 

Содержание 8251498

Страница 1: ... Safety 4 2 2 Additional Safety Operational Guidelines 4 3 OPERATION 5 3 1 Generator Performance Specifications 5 3 2 Electrical Loads 6 3 3 Warning on Sensitive Equipment 6 3 4 Engine Limitations on Generator Performance 6 3 5 Power Receptacles 7 3 6 Circuit Breaker 8 3 7 Automatic Idle Control 8 3 8 LCD Amperage Hour Readout 9 3 9 12VDC Battery 9 3 10 Starting the Generator 10 4 MAINTENANCE 10 5...

Страница 2: ...practice which could result in severe personal injury or death if proper precautions are not taken Caution indicates potentially hazardous situation which may result in minor or moderate injury or damage to unit if proper practices are not taken IMPORTANT SAFETY INSTRUCTIONS Read and understand the operator s manuals and all safety alerts before operating or maintaining your portable generator Be ...

Страница 3: ...spillage possibly causing a fire or an explosion Lubricating oil conforming to the engine manufacturer s specifications must be added to the proper level before operation Failure to fill the crankcase with lubricating oil will void all engine warranties Do not exceed the rated capacity of the generator The total electrical loads at each outlet must be added to determine the total electrical load T...

Страница 4: ... mechanical and electrical condition Do not overload this generator Overloading this generator can cause generator damage powered apparatus damage and excessive heat build up Always keep hands body parts hair and clothing well away from the rotating or HOT parts of the generator set Exhaust systems can cause severe burns Do not start this generator with connected devices turned ON Always make sure...

Страница 5: ...he extension cord s wire gauge is of sufficient size to minimize voltage drop Never handle extension cords or electrical circuits if standing in water or a damp area Operate service or fill with fluids on a level surface only Do not operate this generator in a corrosive or flammable environment Never clean this generator with high pressure water or a garden hose Water can accumulate within the gen...

Страница 6: ...pressor 1 2 hp 1400 Light Bulb Bulb rated Air Compressor 3 4 hp 1800 Nail Gun 1200 Air Compressor 1 hp 2000 Microwave 750 Battery Charger 25A 600 Paint Sprayer 1 3 hp 650 Belt Sander 3 Belt 1000 Paint Sprayer hand air less 175 Circular Saw 6 825 1050 Radio 50 200 Coffee Maker 900 1100 Refrigerator 600 Lawn Edger 550 Table Saw 10 2000 Furnace Fan 1 3 hp 1200 Television 250 550 Hot Plate single 1500...

Страница 7: ...d the generator rating Do not exceed the individual receptacle ratings as shown in Table 3 below Do not exceed the total generator ratings shown in Table 1 on page 5 RECEPTACLE 1 RECEPTACLE 2 20A 120V 20A 120 240V Table 3 Maximum Allowable Receptacle Current Draw RECEPTACLE 1 RECEPTACLE 2 BLACK FILLED LEADS ARE LIVE TERMINALS GREY LEADS ARE GROUND TERMINALS WHITE LEADS ARE NEUTRAL TERMINALS Figure...

Страница 8: ...eaker by pushing the switch to the ON position NOTE ensure that it is safe to reset the switch after power has been cut off The tool appliance being used will operate immediately after the circuit breaker has been reset Use caution 3 7 AUTOMATIC IDLE CONTROL The generator is equipped with an automatic idle feature When activated this feature allows the engine to idle down when there is no power be...

Страница 9: ...sed can be displayed anytime while the generator is running by pressing the black button labeled Amps Hrs Switch directly below the LCD Press the black button again to go back to reading amperage LCD AMP HOURS SWITCH LOW BATTERY WARNING LIGHT Figure 4 Amp Hour Readout 3 9 12VDC BATTERY Please refer to the battery instruction manual provided for battery installation and maintenance information The ...

Страница 10: ...ould display the amperage being drawn from the generator 4 MAINTENANCE Engine Fuel Use Unleaded Gasoline ONLY Engine Oil Refer to the Engine s Operators Manual Engine Maintenance Refer to the Engine s Operators Manual regarding all engine maintenance issues Generator Cleaning ALWAYS shut off the generator and allow the generator to completely cool before performing cleaning operations DO NOT use h...

Страница 11: ... pilot light lit cigarette water heater static discharge etc It is recommended that your generator be started and operated for several minutes at least every 30 days If the generator cannot be operated every 30 days follow the storage recommendations within the engine documentation NOTE A fuel shut off valve is positioned at the base of the fuel tank The valve should be closed during storage perio...

Страница 12: ...12 OF 15 5 PARTS LIST ...

Страница 13: ...13 OF 15 ...

Страница 14: ...UT SPRING 10 24 U TYPE 045 062 6 25 BOLT HEX 250 20 UNC X 1 75 LG GR 5 PTD 2 26 NUT LOCK NYLON 25 20 UNC 5 27 BOLT HEX SRD FLANGE 250 20 X 50 LG 8 28 BOLT HEX SRD FLANGE 10 24 X 50 LG 6 29 SCREW HEX WASHER 10 24 X 50 LG THREAD CUTTING 7 30 NUT SPRING 250 20 U TYPE 11 31 WASHER EXTERNAL TOOTH LOCK 313 2 32 BOLT HEX SER 312 18UNC X 75 LG 2 33 NUT HEX SERRATED FLANGE 312 18 UNC 2 34 BOLT HEX SERRATED...

Страница 15: ... 33 RED 1 64 NSM DECAL 1 65 2460048 FILTER FUEL INLINE 3 16 1 66 10001276 LINE FUEL 3 16 ASSY 1 67 NUT SPRING 10 24 U TYPE 025 040 2 68 8004211 BOLT J M5 X 216 ASSY 2 69 9161274 DECAL WARNING REFUEL 1 70 9160813 DECAL PAL SERIAL 1 71 BOLT HEX SRD 375 16 UNC 1 LG 4 72 ALTERNATOR ANCHOR ROD 1 73 WASHER PTD 281 ID X 625 OD 1 74 WASHER LOCK SPLIT REG 312 PTD 4 75 NUT HEX 250 20 UNC 1 76 BOLT HEX SERRA...

Отзывы: